Laserfiche WebLink
SAN 10AQU IN <br />-COUNTY <br />Environmental Health Department <br />10/23/2019 <br />Large Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />MEINEKE CAR CARE CENTER <br />185 S UNION RD, MANTECA <br />October 22, 2019 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />108 <br />CCR 66265.52 Contingency plan is incomplete. <br />OBSERVATION: The facility contingency plan is missing some mandatory components. The components missing <br />are: mark check box for hazardous waste generator, location of emergency response and spill equipment, <br />emergency coordinator, CUPA phone number. <br />REGULATION GUIDANCE: <br />(a) The contingency plan shall describe the actions facility personnel shall take to comply with sections 66265.51 <br />and 66265.56 in response to fires, explosions, or any unplanned sudden or non -sudden release of hazardous waste <br />or hazardous waste constituents to air, soil, or surface water at the facility. <br />(b) If the owner or operator has already prepared a Spill Prevention, Control, and Countermeasures (SPCC) Plan in <br />accordance with 40 CFR Part 112, or 40 CFR Part 1510, or some other emergency or contingency plan, the owner <br />or operator need only amend that plan to incorporate hazardous waste management provisions that are sufficient to <br />comply with the requirements of this chapter. <br />(c) The plan shall describe arrangements agreed to by local police departments, fire departments, hospitals, <br />contractors, and State and local emergency response teams to coordinate emergency services, pursuant to section <br />66265.37. <br />(d) The plan shall list names, addresses, and phone numbers (office and home) of all persons qualified to act as <br />emergency coordinator (see section 66265.55), and this list shall be kept up to date. Where more than one person <br />is listed, one shall be named as primary emergency coordinator and others shall be listed in the order in which they <br />will assume responsibility as alternates. <br />(e) The plan shall include a list of all emergency equipment at the facility (such as fire extinguishing systems, spill <br />control equipment, communications and alarm systems (internal and external), and decontamination equipment), <br />where this equipment is required. This list shall be kept up to date. In addition, the plan shall include the location and <br />a physical description of each item on the list, and a brief outline of its capabilities. <br />(f) The plan shall include an evacuation plan for facility personnel where there is a possibility that evacuation could <br />be necessary. This plan shall describe signal(s) to be used to begin evacuation, evacuation routes, and alternate <br />evacuation routes (in cases where the primary routes could be blocked by releases of hazardous waste or fires). <br />(g) The plan shall include the current telephone number of the State Office of Emergency Services. <br />CORRECTIVE ACTION: Immediately update the contingency plan to add the missing parts. Maintain the plan <br />on-site and train employees on the plan. Provide a corrective action statement, a copy of the contingency plan and <br />supporting documentation to the San Joaquin County Environmental Health Department (EHD) within 30 days. <br />This is a minor violation. <br />FA0019944 PR0541008 SCO01 10/22/2019 <br />EHD 22-02 Rev. 9/20/2019 Page 6 of 14 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />