1 <br /> FGL <br /> June 9, 2020 Lab ID : STK2036910 <br /> Purviance Drillers,Inc. Customer : 3-14939 <br /> Quality Control - Organic <br /> Constituent Method Date/ID Type Units Cone. QC Data D(X) Note <br /> )r Fanic <br /> t. -D:brYuttoet:anri I:UB? 504 052220:205816MCA Blank ug(L ND <0.02 <br /> LCS ug4' 0.2385 125% 70-130 <br /> LCS uglL 02382 99.5% 1 70-130 <br /> MS ug/L 02403 124% 70-130 <br /> (STK2036952-001) MSD u94- 02419 152% 70-130 •135 <br /> MSRPD, ug/i. 02428 21.2°le 530 <br /> QMDL I ug/L 0.01979 110% 60-140 <br /> 1,3-Dibromopropane 504 05/22/20:205816MCA Blank ug/L 0.5548 93.7% 70-130 <br /> LCS ug/L 0.5598 110% 70-130 <br /> LCS ug/L 0.5591 107% 70-130 <br /> MS uglL 0.5639 112% 70-130 <br /> (STK2036952-001) MSD u9/L 0.5677 129% 70-130 <br /> MSRPD U911- 0.2428 15.21/a 530 <br /> MDL u 0.5849 127% 70-130 <br /> Ut3CP _ i.15/22120:205816MCA Blank ug(L ND <0.01 <br /> LCS U911- 0.2385 119% 70-130 <br /> LCS ug/L 0.2382 117% 70-130 <br /> [vis ugfL 02403 121% 70-130 <br /> (STK2036952-001) MSD ug/L 02419 153% 70-130 435 <br /> MSRPD ue/L 0.2428 23.84/6 _<30 <br /> QMDL u 0.01979 107% 60-140 <br /> I 3DBP 504.1 05/2320208334MCA CCV ugn. 7.481124% <br /> 70-130 <br /> CCV a 9.975 123% 70-130 <br /> SO4.1 052320:M8335MCA CCV ug/L 7.481 114% 70-130 <br /> CCV u 9.975 119% 70-130 <br /> DBCP 504.1 05!7320:208334MCA CCV ug/L 2.000 1280/. 70-130 <br /> CCV I u Z 5.000 121% 70-130 <br /> 504.1 052320:208335MCA CCV ug/1_ 2.000 116% 70-130 <br /> CCV ugfL 5.000 129% 70-130 <br /> FDP, 504.1 05123P0:208334MCA CCV u9n, 2.000 114% 70-130 <br /> CCV 110. 5.000 111% 70-130 <br /> 4 I 052320:208335MCA CCV ug/L. 1000 109% 70-130 <br /> CCY u x.000 138% 70-130 360 <br /> Definition <br /> CCV Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS Laboratory Control Standard/Sample:-Prepared to va*,that the preparation process is not affecting analyte recovery. <br /> Ms :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD -Matrix Spike Duplicate of MSIMSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD MSIMSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Resultwas below the DQO listed for the analyte. <br /> DQO Data Qualitv Objective-This is the criteria against which the ualit)control data is compared. <br /> Explanation <br /> 360 :CCV above Acceptance Range(AR).Samples which were non detect for this analyte were accepted. <br /> 435 Sample matrix may be affecting this analyte.Data%vas accepted based on the LCS or CCV recovery <br /> Page 6 of 6 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 583 E.Lindo Avenue 3442 Empresa Drive,Suite D 9415 W.Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 Visalia.CA 93291 <br /> TEL:(805)392-2000 TEL(209)942-0182 TEL:(530)343-5818 TEL:(805)783-2940 TEL:(559)734-9473 <br /> Env FAX:(805)5251t172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX.(805)783-2912 FAX:(559)734-8435 <br /> CA ELAP Certification No.1573 CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 CA ELAP Certification No.2810 <br />