ROBISON <br /> ALL SECTIONS OF SWITCHBOARD ENGINEERING, INC <br /> MUST BE BONDED TOGETHER <br /> SECTION 384-3(c) MAIN SERVICE EQUIPMENT -1200A 1940140TH AVE W.,SUITE 302 <br /> LYNNWOOD,WA 98036 <br /> RACEWAY/CONDUIT 206-364-3343 TEL <br /> \ CONTACT:TYLER BEAM <br /> SERVICE NEUTRAL `—(2) SETS OF 350 KCMIL COPPER <br /> (GROUNDED CONDUCTOR BONDING BUSHING <br /> SECTION 250-94 O eR0SIO�gI <br /> E R <br /> NEUTRAL DISCONNECT <br /> Cl) <br /> MEANS. SECTION 230-75Z <br /> GROUNDING ELECTRODE CONDUCTOR \ w N0. E-21545 m <br /> SECTION 250-66, 250-68, 250-62, 250- 0 <br /> 2/0 CL. NEUTRAL BUS MAIN BONDING JUMPER <br /> SECTION 250-102, 250-94, 250-92, 250-122F�FCTRV�P���P <br /> EXOTHERMIC WELD qTF OF CA��F�� <br /> <a S <br /> OR CONTINUOUS #2 CU. GROUNDING BUS Seal° <br /> ENCASED IN CONCRETE <br /> SUPPLEMENTAL ELECTRODE 4d <br /> 1/2" MIN. REBAR GROUNDING ELECTRODE CONDUCTOR <br /> REQUIRED IN ADDITION TO A 4 4SECTION 250-66, 250-68, 250-62, 250-70 <br /> WATER PIPE GROUND ° <br /> bp <br /> SECTION 250-50((1)(2) 9 < a a 4 a <4 A --- 2/0 CU. <br /> 20' OF #4 BARE COPPER MIN. ENCASED IN <br /> °a a CONCRETE. NEC 250.52 (3) <br /> GROUNDING ELECTRODE <br /> SECTION 250-50 <br /> BONDING JUMPER <br /> SIZED PER 250-122 / <br /> 1/0 CU. <br /> (2) 5/8" X 8' GALVANIZED <br /> STEEL GROUND RODS SPACED M WATER SERVICE TO BUILDING <br /> SIZED PER 250-122 <br /> MIN OF 12' APART. 1/0 CU. GROUND CLAMP (TYP) <br /> * EQUIPMENT BONDING CONDUCTORS <br /> HOT WATER PIPE SECTION 250-102, 250-122 <br /> GR 0 UNDING DETAILS <br /> SCALE: NONE J <br /> Q <br /> M <br /> D <br /> Cn <br /> 300 A <br /> 480Y/277V z <br /> CW-H <br /> > o <br /> LU <br /> D:f 0 <br /> Z <br /> PGE APPROVED SWITCHBOARD o <br /> WITH PULL SECTION AND J <br /> METERING COMPARTMENT 300/3 NOTES. <br /> QSR INTERIOR QSR EXTERIOR - NEMA 3R MCB MSB-2 UNITIZED PANEL SYSTEM (CPI, INC.) INTERIOR_ a <br /> 200 A 7 F 800 A 2000 A 1. ALL SERVICE EQUIPMENT, INCLUDING METER & CURRENT TRANSFORMER z <br /> 208Y/120V I 208Y/120V 208Y 120V OV I I I 300 800 A CABINET TERMINATION BOXES, DISCONNECT SWITCHES, AND MAIN <br /> I I CIRCUIT BREAKERS SHALL BE RATED FOR THE MAXIMUM AVAILABLE ao <br /> MSB-1 200 A 200 A 200 A 100 A 100 A SHORT CIRCUIT CURRENT AS DETERMINED BY THE SERVING UTILITY CO. L N <br /> 480Y/277V CW-T I 200 208Y/120V 208Y/120V 208Y/120V 208Y/120V 208Y/120VI 2, DESIGNED AIC RATINGS BASED ON PROPOSED 300KVA UTILITY o <br /> 200/3 TRANSFORMER WITH 2.1% IMPEDANCE. ELECTRICAL CONTRACTOR TO CD <br /> = I 1000/3 I 208Y/120V 300kVA I A B C G L I CONFIRM ACTUAL AVAILABLE FAULT CURRENT WITH LOCAL UTILITY AND L <br /> MCB ( 200/3 MAKE REVISIONS TO EQUIPMENT AIC RATINGS PRIOR TO ORDERING AND a a a a a a a <br /> MLO I 800.0 INSTALLATION. ELECTRICAL CONTRACTOR SHALL NOTIFY ENGINEER OF <br /> U I I I 800/3 I I I CHANGES. <br /> 1000 A MCB 200 3 MCB 200/3 MCB / 200/3 MCB / 100/3 MCB / 100/3 <br /> a. M I 208Y/120V I / \ \ \ I 3. ALL CONDUCTORS SHALL BE STRANDED COPPER TYPE THHN/THWN. <br /> M I 200 I M CW-L 4. GROUNDING ELECTRODE CONNECTIONS SHALL BE MADE WITH A U.L. <br /> 800.A ^ I I I LISTED AND APPROVED BOLTED PRESSURE OR COMPRESSION TYPE <br /> OD LL <br /> 800/3 800/3 CONNECTOR. <br /> MLO I 5. GROUND RODS (IF NEEDED) SHALL BE 3/4" DIA. X 10' LONG <br /> XFMR MLO 200 COPPERWELD. RESISTANCE TO GROUND MUST BE 25 OHMS OR LESS. <br /> 3 500 KVA I I MLO I 200 I 6. CONCRETE ENCASED (UFER) GROUNDING ELECTRODES SHALL CONSIST Q <br /> o OF AT LEAST 20 FEET OF ONE OR MORE STEEL REINFORCING BARS OR W <br /> a PRI UTILITY I I I 100 I RODS OF NOT LESS THAN 1/2 INCH DIAMETER, OR CONSISTING OF AT <br /> C _ LEAST 20 FEET OF BARE COPPER CONDUCTORS NOT SMALLER THAN <br /> In SEC 208Y/120V I 2000U - I 100 I #2/0 AWG, ENCASED BY AT LEAST 2 INCHES OF CONCRETE, LOCATED o W Cy) <br /> W 3/0 CU. GRD I 1000 WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR > M <br /> i UFER GROUND <br /> J FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH. ) 0 Q L <br /> 800.A 7. CONNECT GROUNDING WIRE DIRECTLY TO GROUND ROD. MINIMIZE _ <br /> z ,,. <br /> CONDUCTOR RIGHT ANGLE BENDS. MAXIMUM LENGTH OF CONDUCTOR 0 <br /> ONE-LINE DIAGRAM Q <br /> SHALL BE 10 FEET. , Q 0 0 <br /> d SCALE: NONE 8. SUPPLY EXACT NUMBER OF DEDICATED ISOLATED GROUND RECEPTACLES J <br /> W <br /> 0 <br /> FOR LINE CONDITIONED EQUIPMENT. NO UNUSED DEDICATED ISOLATED U <br /> O GROUND RECEPTACLE SHALL BE INSTALLED. IF A RECEPTACLE IS <br /> 3INSTALLED THEN NOT USED. CONTRACTOR SHALL REMOVE RECEPTACLE Coco1J.J <br /> FEEDER SCHEDULE AND INSTALL BLANK COVER ON JUNCTION BOX. <br /> 171170.10 <br /> 9. USE OF SERIES-CONNECTED INTERUPTTNG RATINGS FOR CIRCUIT0 Z <br /> ID FEEDER CONDUIT AND FEEDER FEEDING BREAKERS IS ACCEPTABLE PROVIDED THE CIRCUIT BREAKER LL Q <br /> 00 <br /> k' AMPS THESE COMBINATIONS ARE RECOGNIZED BY UNDERWRITERS LABORATORIES 0 Q <br /> Z DEVICES UNDER THE "CIRCUIT BREAKERS - SERIES CONNECTED" PRODUCT Z <br /> CATEGORY. U Q <br /> 0 100 100 1-1/2"C,3#1,#1N,#8G G, L �J.J <br /> U <br /> 10. CONTRACTOR SHALL PROVIDE ARC FLASH WARNING LABELS AS (n <br /> a 200 200 2"C,3#3/0,#3/ON,#6G A, B, C, P1 REQUIRED BY CEC 110.16. <br /> a. <br /> 300 300 3"C,3#350kcmil,#350kcmil N,#2G CW-H 11. PROVIDE DEDICATED NEUTRAL WIRES FOR ALL MULTI WIRE BRANCH <br /> i' 800 (3)3"C,3#400kcmil AL,#400kcmil AL N,#3/0 ALG MSB-2 CIRCUITS AS REQUIRED BY CEC 210.4. <br /> N UNITIZED 12. SEPARATION OF ELECTRICAL CIRCUITS FOR ELECTRICAL ENERGY <br /> N 800.A PANEL MONITORING IS REQUIRED PER CALIFORNIA TITLE 24 NON-RESIDENTIAL <br /> o SYSTEM, PART 6 SECTION 8.3. <br /> QSR Project Number <br /> 800.0 800 (3)3"C,3#300kcmil,#300kcmil N,#1/OG CW-T SPA16002.0 <br /> 1000 1000 (3)3"C,3#400kcmil,#400kcmil N,#2/OG CW-L <br /> Jv <br /> w Sheet Name <br /> 2000U 2000 (5)3-1/2"C,3#600kcmil,#600kcmil N MSB-1 <br /> 0 <br /> N SIZING METHOD: COPPER, 60°C #12 THROUGH #1, 75°C 1/0 AND ABOVE SINGLE LINE <br /> U <br /> DIAGRAM <br /> U <br /> Q <br /> d <br /> Z <br /> W <br /> Y <br /> U <br /> Q <br /> QSheet Number <br /> U <br /> O <br /> W EOm3m <br /> 1 <br /> L� <br />