Laserfiche WebLink
F-3 SITE PLAN NOTES NOTES BY SYMBOL "O"APPLICABLE TO ALL PLANS. UU 0 <br /> WP GFCI WP GFCI <br /> +24" AFF +24" AFF A. REFER TO SHEET E2.1 FOR GENERAL NOTES AND E10.0 FOR SPECIFICATIONS. O PROVIDE 2 - 5" CONDUITS ROUTED FROM THE UTILITY PAD MOUNTED TRANSFORMER TO THE POWER COMPANY 12 PROVIDE A 24"W X 36"H X 6" DEEP TELEPHONE ENCLOSURE WITH A PLYWOOD BACKBOARD. PROVIDE A #6 AWG CU <br /> F+ SERVICE POINT. PROVIDE ALL TRENCHING, BACK FILL & CONCRETE ENCASEMENT AS REQUIRED BY POWER GND WIRE TO MSB AND A QUAD 120V RECEPTACLE AT TELCO BACKBOARD. <br /> B. ALL SERVICE REQUIREMENTS (POWER AND TELEPHONE) TO RENDER SERVICE TO THE COMPANY. REFER TO THE CIVIL UTILITY PLAN AND THE UTILITY SERVICE PLAN FOR ALL ELECTRIC SERVICE Architecture / Development <br /> ♦ PROJECT SHALL BE VERIFIED WITH THE SERVING UTILITY COMPANIES PRIOR TO BID. REQUIREMENTS PRIOR TO THE BASE BID & ROUGH-IN. INSTALL PER ALL UTILITY REQUIREMENTS. 13 PROVIDE , 1 P, 120V RATED WEATHERPROOF DISCONNECT FOR DIRECTIONAL SIGNS, MONUMENT SIGN, AND O.S <br /> MENU SIGNNV.L. REFER TO SIGNAGE PACKAGE FOR EXACT SIGN LOCATIONS. <br /> ALL COSTS LEVIED BY THE UTILITY COMPANIES SHALL BE INCLUDED IN THE BASE 14901 Quorum Drive <br /> LINEN CART 2 PROVIDE 4 SETS OF 4 CONDUITS ROUTED FROM THE UTILITY PAD MOUNTED TRANSFORMER TO CT CABINET - <br /> BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED AFTER BIDDING PERIOD. METER. PROVIDE ALL TRENCHING, BACK FILL & CONCRETE ENCASEMENT AS REQUIRED BY POWER COMPANY. 4 PROVIDE (3) - 1"C. CONDUITS TO MIS ROOM FROM MENUBOARD. Suite 300 <br /> REFER TO THE CIVIL UTILITY PLAN AND THE UTILITY SERVICE PLAN FOR ALL ELECTRIC SERVICE REQUIREMENTS Dallas Texas 75254 <br /> BUN BUN (ON) F-1 C. VERIFY SWITCHBOARD METERING AND CONSTRUCTION REQUIREMENTS WITH PRIOR TO THE BASE BID & ROUGH-IN. 15 2 # 12, 1 # 12 G. 3/4" CONDUIT. (972)239-8884 <br /> WP GFCI POWER COMPANY. Ph: <br /> RncK RACK LIGHT SWITCH, Fax: (972)239-5054 <br /> +24'" AFF WP +48" AFF D. INSTALL POWER AND TELEPHONE SERVICE CONDUITS BELOW GRADE O PROVIDE 1 - 4" CONDUIT (TELEPHONE) & 1-2" CONDUIT (FOR CATV), EACH ROUTED FROM THE IN-N-OUT 1s PROVIDE A DEDICATED 1" CONDUIT FROM THE INDICATED LOCATION TO THE INTERIOR JUNCTION BOX FOR SECURITY <br /> USED OIL ENCASED IN CONCRETE (IF REQUIRED), PER UTILITY COMPANY BURGER TELEPHONE SERVICE BACKBOARD TO TELEPHONE COMPANY SERVICE POINT AND THE CAN SERVICE CAMERAS. REFER TO SHEET E7.0 FOR FURTHER INFORMATION. ISSUE RECORD <br /> STORAGE BIN (ON) F-1 1Q REQUIREMENTS. BACKBOARD TO THE CATV COMPANY SERVICE POINT. PROVIDE ALL TRENCHING, BACK FILL & CONCRETE DATE DESCRIPTION <br /> F-2/4/6 ENCASEMENT AS REQUIRED BY TELEPHONE COMPANY. REFER TO THE CIVIL UTILITY PLAN AND THE TELEPHONE 17 PROVIDE 3/4" CONDUIT FOR CONNECTION BETWEEN SPEAKER AND MENU BOARD. URBAN PROTOTYPE DESIGN <br /> E. REFER TO SHEET E9.0 FOR LIGHTING CONTROLS. SECURITY NIGHT LIGHT UTILITY SERVICE PLAN FOR ALL REQUIREMENTS PRIOR TO BASE BID & ROUGH-IN. INSTALL PER ALL UTILITY 10-22-2018 ISSUED FOR PERMIT <br /> x� SHALL BE PROVIDED WITH SEPARATE OVERRIDE SWITCH. REQUIREMENTS. 18 1 1/2" CONDUIT INTO BUILDING FOR FIRE ALARM MONITORING WIRING ACCESS. ROUTE CONDUIT IN TRENCH ALONG <br /> CD <br /> WITH FIRE PROTECTION SYSTEM WATER LINE. <br /> 21 F. REFER TO SHEET E11.0 FOR EXTERIOR LIGHT PHOTOMETRICS. O PROVIDE PARKING LOT LIGHTING FIXTURES TYPE AS INDICATED, TYPICAL. <br /> z OS Q N TRASH COMPACTORS G. COORDINATE LOCATION OF LIGHT POLE BASES WITH CIVIL, LANDSCAPING <br /> O 1 1/2" CONDUIT TO THE HOME PA SYSTEM 9 PROVIDE 3/4"C. TO CEILING MOUNTED SPEAKERS FROM SECURITY/UPS RACK. <br /> m <br /> -71 o PUSH-BUTTON CONTROL AND IRRIGATION. 20 PROVIDE GFI DUPLEX RECEPTACLE FOR POWER CONNECTION TO HEAT TRACE DEVICE AT HOSE BIBS. <br /> o Q ; O REFER TO ENLARGED TRASH ENCLOSURE PLAN E1.0/3. <br /> \_ <br /> 0- o H. BURIAL DEPTH OF CONDUITS UNDER PARKING LOT IS 24" BELOW GRADE. 21 PROVIDE A PERMANENT PLAQUE "PANEL F IS LOCATED INSIDE TRASH ENCLOSURE". <br /> vq o O 2 # 10, 1 # 10 G. 3/4 CONDUIT. 02 # 8, 1 # 10 G. 3/4 CONDUIT. <br /> 0 LIGHT SWITCH, O IRRIGATION CONTROLLER, VERIFY EXACT LOCATION WITH IRRIGATION CONTRACTOR. 22 ALL EXTERIOR GFI/WP RECEPTACLES LOCATED ON POLE LIGHTS SHALL BE REQUIRED WEATHERPROOF COVER, WITH <br /> ATTACHMENT PLUG CAP INSERTED INTO RECEPTACLE ("IN-USE" TYPE) AS PER NEC 406.9(6). <br /> WP +48" AFF UTILITY REPRESENTATIVES O 1'X4' RECESSED LIGHTING FIXTURE TYPE "D1" ON PLASTER CEILING, TYPICAL REFER TO ARCHITECTURAL DWG. <br /> o FOR LOCATION. O CONTRACTOR TO PROVIDE 2 SEPARATE SETS OF WIRING WITH ASSOCIATED LIGHTING CONTROL RELAYS ONE REVISION RECORD <br /> CONTROLS LIGHTS FACING NORTH FOR INOB PARKING LOT; AND OTHER RELAY TO CONTROL LIGHTS FACING SOUTH). <br /> 3 ELECTRIC PROVIDER: 0 3 # 12, 1 # 12 GND, 3/4" CONDUIT. IN THE FUTURE, INOB'S LIGHTING CIRCUIT HOMERUN & CONTROL SHALL BE DISCONNECTED FOR OTHER SOUTH <br /> Southern California Edison BUILDING TO BE POWERED & CONTROLLED. <br /> Tracey Bass, SCE Project Manager 0TRASH COMPACTOR 7 FLA, 208V, 30CONNECT TO THE CIRCUIT BREAKER AS SHOWN IN DESIGNATED CIRCUIT <br /> „ „ e-mail: Tracey.Bass©sce.com . O THIS POLE LIGHT FIXTURE SHALL BE WIRED THE SAME SOUTH LIGHTS CIRCUIT AND RELAY ONLY. EXTEND 3/4> <br /> PANEL' F WITH MCB SUITABLE FOR SERVICE Cell: 949-697-1424 HOMERUN. PROVIDE A ON/OFF PUSH-BUTTON CONTROL SWITCH AND MOUNTED @ +52 A.F.F MAXIMUM. EMPTY CONDUIT WITH PULL STRING TO EXISTING BLDG. K (SOUTH) FOR FUTURE POWER AND CONTROL CONNECTION. <br /> ENTRANCE ISCONNECT PER NEC. SECTION Ph: 949-587-5416 <br /> 225.36. PANEL IS PROVIDED SERVICE VERIFY EXACT CONDUIT TERMINATION WITH THE BLDG. OWNER PRIOR TO ROUGH-IN. <br /> 'GROUND AT THE P EL LOCATION. REFER TO CABLE PROVIDER: <br /> SINGLE LINED M SHEET E2.0 Frontier Communications (copper & fiber) <br /> Phillip Olivas, BAU Engineer -Engineering West <br /> Frontier Communications <br /> e-mail: phillip.olivas©ftr.com <br /> ENLARGED Ph: 626-513-4573 <br /> TELEPHONE PROVIDER: <br /> TRASH ENCLOSURE (copper Frontier Communications co er & fiber) <br /> 03 SCALE: NOT TO SCALE Phillip Olivas, BAU Engineer -Engineering West <br /> Frontier Communications <br /> e-mail: phillip.olivas©ftr.com <br /> Ph: 626-513-4573 <br /> PROfES-Sl L <br /> m Q 0 <br /> J o 36"RCP SD o J <br /> J <br /> ® Q <br /> 044 <br /> 36"RCP SD M < NIL z I <br /> ~ m m m <br /> Q m Q N QX➢ <br /> z � 0 t <br /> z - z I CN z dj �I�`•CTRIGP�. <br /> z Q V) Q 1 <br /> z � OFCAUF p <br /> TYPICAL SITE o w z J LJ =z cn IL--L �Ww = Q� W W /,L� I Gr�yli`G ,�,SSGCe <br /> LIGHTING FIXTURE Ld z o W LJ 0 z = <br /> (SEE DWG. E11.0 Jz= �� Qom ��o �P��� <br /> FOR LIGHTING NOTE : <br /> D0~ ° _ two who � <br /> SPECIFICATIONS) I �� <br /> 15"PVC SD PA <br /> PA m PA m <br /> ft') <br /> TWO DAYS BEFORE SIDEWALK Q < <br /> YOU DIG CALL U.S.A. T JT JT <br /> TOLL FREE 811 E R —5" PG&E J -5 PG&E E <br /> POLE RgMp X00 �21 _(MB�U 7"TREE PA o EJ VACANT LAND <br /> k1r,.-t M <br /> ADA SIGN SIGN v �� APN:191-190-65 <br /> (SEE DWG. E11.0 Q GFI WP oQ0 J G /WP O � LLz engineering consultants <br /> FOR LIGHTING O �Pr� 0t� � _ _ _ 7 13 (0N)B-42 � �M 4 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> SPECIFICATIONS) ® B-20 ODA r) nCD O `S. rtmassociates.com 1 972.387.3500 <br /> ® RELOCATED <br /> 3"T E 4.,W STOP SIG J M M O 3 NU BOA ® - FS 18.GHAA.033 <br /> B-21/23 s <br /> O U 3 16 <br /> 2 16 4 yX I VII+) 4 VIII 5 PROTOTYPE VERSION <br /> ol PRPP <br /> 17 <br /> URBAN DESIGN <br /> 12 ELEPHONE <br /> I � 3 6��1)7 CAN BOAR — — — — — — -voH- PROJECT NAME <br /> HANDHOLE ® E — El- <br /> O r o (ON)+B-22 PNL. A@ MAIN SERVICE 2 -N-OUT- <br /> & COVER ( EXISTING OLE LIG PNL. Bu SWBD "MSB" <br /> � (SECURITY L�HT) PNL. D o 21 � 8 IN <br /> 0 UT <br /> TO REMAI (TYP.) <br /> GROUND LUG J 14.50FF (ON) B-22 I CLEAN AIR BURGER <br /> THE METAL POLE MUST BE 1 M (SECURITY LIGH 19 R H AN POOL/El <br /> TR <br /> CONNECTED TO AN EQUIPMENT <br /> o s ON) B-17 0 <br /> FIRE LANE AND <br /> BASE PLATE BY LIGHT GROUNDING CONDUCTOR OFA NO SEMI-TRUCKS B 5 CD > G <br /> 1 CONDUIT o z --i R LATH RO P <br /> TYPE FOUND IN NEC 250.118 M co EC. <br /> POLE MANUFACTURER PRS r- _ _ _ <br /> 14.20TC �� XII I CUSTOMER U z ``' CO 0 <br /> PROVIDE NON-SHRINK GROUT -- I / X ENTRANCE o o <br /> 13.70TOG,UNDER BASE PLATE 3T - <br /> 4 CALIFORNIA <br /> . ® g O ODI Jo LLER o <br /> CONCRETE POLE BASE ANCHOR BOLTS SET ® — — — TR 16 ® R� 6 16514 GOLDEN VALLEY PKWY <br /> MATCH SHOPPING WITH TEMPLATE FROM eta O _ O <br /> POLE MANUFACTURER R S LK � F - LATHROP CA 95330 <br /> CENTER DESIGN ® GIP/ 12.961NV. R R I �51G <br /> (SIZE AS REQUIRED Ot�l B 42 RD POC �3 5F�1OG <br /> WHERE APPLICABLE. <br /> a ca ❑ o o°000g Beaoo"' o'a ogs° e a ooeoaooa oo ooao e=a J ( ) 3.2 <br /> BY LIGHT POLE I LL <br /> E 7 <br /> MANUFACTURER). `�' O ( )B-40 <br /> FINISHED GRADE a a ° 4. LEVEL POLE WITH WP 4 OA <br /> 6"W <br /> LEVELING NUTS. R <br /> GROUT UNDER BASE PA O (ON)B 40 <br /> WP <br /> PLATE ® N0 ® NO ~ J J <br /> a El A EV PARKING V PARKING <br /> Q ° ° ( 0 ILQT ENTER SIGN R 0A1 <br /> ° <br /> P � ��l s O TOHRV <br /> RIUESIGN INNmOUT <br /> a 9 <br /> e - 7A 16 N N \BVRGERo <br /> o B-13 D <br /> CONDUIT AS SIZED CIRCUIT HOMERUN WILL BE GO BLE A <br /> SS AMERI C+ <br /> ON PLANS DISCONNECTED & REMOVED IN <br /> B-27/29 <br /> THE FUTURE FOR SOUTH BDLD. <br /> — 0 BE POWERED & CONTROLLED. 7A 1 PROJEC NORTH TRUE NORTH <br /> A2 OA2 4 0 10 0 40 60 <br /> 4 PROJECT NUMBER <br /> J <br /> ° a 1 <br /> G PHIL SCALE 180641.001 <br /> 2" DP SD CALE: 1"=20' <br /> SC NDE 24 <br /> SHEET TITLE <br /> 5 3 <br /> a a ELECTRICAL SITE <br /> a °° g PLAN NOTES AND <br /> Ir <br /> R — DETAILS <br /> PARKI ,► <br /> N SITE LIGHTING STANDARD. D 0 EA R <br /> 06 PV <br /> 02 SCALE: NOT TO SCALE <br /> � V <br /> O O <br /> NOTE: PA J wdo <br /> REFER TO STRUCTURAL PLANS FOR POLE BASE / P R IPM v o <br /> Z Z STRUCTURAL DESIGN DETAIL & CALCULATION E L E P APN 1 91-190-64 ITE PLAN z ■ <br /> 0 o ADA LEFT ARRO S 3KA AA1.o w <br /> SCALE:1 =2 -� <br /> n CD 7 <br />