Laserfiche WebLink
SAN _J O A Q U I N Environmental Health Department <br /> COUNTY AMENDED <br /> 8/13/2020 <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> H&H ENGINEERING CONST INC 212 INDUSTRIAL DR, STOCKTON August 06,2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CORRECTIVE ACTION: Have a qualified Professional Engineer prepare a tank assessment for the 300 gallon <br /> used oil tank. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. Provide a copy of all tank assessments,when available. <br /> This is a Class I violation. <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite. <br /> OBSERVATION: The facility has a 300 gallon used oil hazardous waste tank but does not have three years of <br /> complete daily tank inspection records. <br /> REGULATION GUIDANCE: <br /> (a)The owner or operator shall inspect,where present,at least once each operating day: <br /> (1)overfill/spill control equipment(e.g.,waste-feed cutoff systems, bypass systems, and drainage systems)to <br /> ensure that it is in good working order; <br /> (2)the aboveground portions of the tank system,if any,to detect corrosion or releases of waste; <br /> (3)data gathered from monitoring equipment and leak-detection equipment,(e.g., pressure and temperature <br /> gauges, monitoring wells)to ensure that the tank system is being operated according to its design; <br /> (4)the construction materials and the area immediately surrounding the externally accessible portion of the tank <br /> system including secondary containment structures(e.g.,dikes)to detect erosion or signs of releases of hazardous <br /> waste(e.g.,wet spots,dead vegetation);and <br /> (5)for uncovered tanks,the level of waste in the tank,to ensure compliance with section 66265.194(b)(3). <br /> (c)The owner or operator shall document in the operating record of the facility an inspection of those items in <br /> subsection(a)of this section. <br /> CORRECTIVE ACTION: Immediately start conducting and documenting complete daily hazardous waste tank <br /> inspections. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0010339 PRO514288 SCO01 08/06/2020 <br /> EHD 22-02 Rev.9/20/2019 Page 11 Of 19 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />