Laserfiche WebLink
I in <br /> CERAMIC OR PORCELAIN WALL TILE > <br /> 1/4" GAP CERAMIC OR PORCELAIN WALL TILE <br /> FLEXIBLE SEALANT AND <br /> COMPRESSIBLE BACK-UP. HIGH PERFORMANCE CEMENT GROUT <br /> WHEN REQUIRED Z <br /> PORCELAIN FLOOR TILE LATEX-PORTLAND CEMENT THIN SET MORTAR PORCELAIN TILE <br /> LATEX-PORTLAND CEMENT THIN SET MORTAR HIGH PERFORMANCE CEMENT GROUT 0 <br /> QUARRY TILE LATEX-PORTLAND CEMENT THIN SET MORTAR w <br /> HIGH PERFORMANCE CEMENT GROUT EPDXY GROUT, 100% SOLIDS 0 <br /> CEMENT BACKER BOARD <br /> CONCRETE, ON-GROUND MODIFIED-PORTLAND CEMENT THIN SET MORTAR CONCRETE, ON-GROUND <br /> VAPOR RETARDER MEMBRANE CONCRETE, ON-GROUND <br /> R I <br /> ° d p ° d p WOOD OR METAL STUDS p ° d d °d d p Q <br /> °4 dd d° p p d d p p ° ° I � <br /> p d ° dp d d ° d d p <br /> p ° d p p d d <br /> I 11TJ <br /> Q } o rn <br /> DINING ROOM INTERIOR WALLS KITCHEN/SUPPORTZ 0 W N W o Nco <br /> 5 DINING ROOM PERIMETER JOINT 4 OVER WOOD OR METAL STUDS 3 FLOORS OVER CONCRETE 2 FLOORS OVER CONCRETE NOT USED � 5 N0 � � ior 04 a. <br /> A5.2 NOT TO SCALE A5.2 NOT TO SCALE A5.2 NOT TO SCALE ir <br /> A5.2 NOT TO SCALE A5.2 NOT TO SCALE Q <br /> ARCHITECT OF RECORD: <br /> ROOM FINISH SCHEDULE WALL TILE SCHEDULE FLOOR TILE SCHEDULE ,0 ARC,y/T <br /> NO. ROOM NAME FLOOR BASE WALLS CEILING WALL MORTAR SETTING BED GROUT FLOOR BASE MORTAR SETTING BED GROUT V CRAIG S. <br /> BLUME-- <br /> * N .- -31661 <br /> � � � �' C1 J REN.3/3112021 co <br /> Ld W J ^. Z U J w <br /> CD <br /> W z z W <br /> C> cn z zCD <br /> ¢ <br /> w �cS�y/ ,bG �G �y <br /> =) o r- ¢ <br /> cn m m oom zCD - ow <br /> c J m � m Z a w C14 I of <br /> (Y N r m N <br /> E3 w W D W z U J z W U <br /> C> cl:f ^N W j c v N m m � Q w v ¢ Q <br /> U W o r > O CC - w W W ~ U) W w y ON <br /> z <br /> _j J_ o m W w Q U U W 0 U O J J m N = O J cn <br /> J J - > m m r <br /> w cn 0 00 W W m m N o Z m z v <br /> y r w z i > > U v ¢ w ¢ > ¢ o W o <br /> Qofu ' mooQQ � zC)-5LC3c¢ ww Cf) <br /> Of 0- > wwm d mOfOfQaw� z� <br /> 0 <br /> wz z o JZ J x X r � � wr U Cn c) F-- 4 :> w <br /> so <br /> 100 CUSTOMER SERVICE • • • 9 1 • • • CERAMIC OR PORCELAIN WALL TILE TILE NOTE 4C LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT PORCELAIN FLOOR TILE (TILE NOTE 3) NONE - WALL TILE TILE NOTE 4A LATEX-PORTLAND CEMENT THIN SET MEDIUM BED HIGH PERFORMANCE CEMENT GROUT <br /> 101 DINING • • • • • • • CERAMIC OR PORCELAIN WALL TILE (TILE NOTE 4B & 4C) LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT PORCELAIN FLOOR TILE (TILE NOTE 3) NONE - WALL TILE LATEX-PORTLAND CEMENT THIN SET (MEDIUM BED) HIGH PERFORMANCE CEMENT GROUT <br /> W <br /> ILI� <br /> E <br /> 0 o <br /> P � <br /> O U N <br /> d a o c; <br /> w V P U <br /> W � omtE <br /> 0 3 <br /> C � N <br /> 7 °w dl C N <br /> a 0 C ° O ` 0 o <br /> d Svc *' <br /> � J <br /> o � art; -ov <br /> J 0- 0 acv° ao <br /> ai d <br /> o ., ° alit <br /> 2 E L_ <br /> _ a " o <br /> ° co>c� a� 0" oo <br /> m�;or �� <br /> co GO) <br /> ° Iry ° <br /> o '- O. <br /> C p 0 3 o <br /> O U C� v C L <br /> ++ C O v�+ <br /> y p U 0 0 C O <br /> N r B� cl <br /> vcc+3a. v <br /> i c O�'(A E V C <br /> ° 0vCO- X_ <br /> a) c O y <br /> O J C O v d <br /> r UQQ Crt�+ ID <br /> � U- <br /> O �' ` `_ <br /> a ai NF; o <br /> 04 <br /> Q dl O'U d <br /> SLOW) L <br /> 0 030 <br /> DOOR HARDWARE NOTES: <br /> o ° u, -� ao <br /> TILE NOTES GENERAL NOTES �'4- <br /> 0 0 0L, 0- 00 <br /> O L <br /> 1 . ENCE: 2013 McDONALD'S PROJECT MANUAL - SECTION 09300 1. WHEN BUILDING TYPE IS A NON-COMBUSTIBLE CATEGORY, ALL PLYWOOD ,� ® o �'� v` 5 <br /> HARDWARE NOTES: N a� > ; y a�2 $ <br /> SHALL BE FIRE RETARDANT TREATED. Q ° ao ° - <br /> 1 . ALL EXIT DOORS SHALL BE KEYLESS IN THE DIRECTION OF EGRESS. 2. QUARRY TILE: a N O- 4' go Z N <br /> W t �•- O OL NL <br /> 2. THE OPENING FORCE OF ALL EXTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 lbs. 2. FRP PANELS: 8-3: c+' U) <br /> 3. THE OPENING FORCE OF ALL INTERIOR PUSH/PULL DOORS SHALL NOT EXCEED 5 lbs. DAL-TILE "DIABLO RED" 6X6 ABRASIVE TILE WITH BLACK GROUT 0- <br /> a. FRP OVER CEMENT BD BEHIND 3-COMP SINK TO HEIGHT OF BACK <br /> 4. PROVIDE PANIC HARDWARE FOR ALL EXTERIOR DOORS AS NOTED ON THE DOOR SCHEDULE ALT: "ASHEN GRAY" 6X6 ABRASIVE TILE WITH BLACK GROUT SPLASH <br /> 5. ALL DOOR HARDWARE SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE <br /> 6. DOOR HARDWARE LISTED BELOW IS FOR REFERENCE (FOR REPLACEMENT OR REPAIR) ONLY UNLESS NOTED OTHERWISE. 3. FLOOR TILE: b. FRP OVER CEMENT BD OVER EXTERIOR GRADE PLYWOOD (NOTE 5) AT <br /> 7. NOT ALL HARDWARE LISTED BELOW MAY BE USED. SEE Al SERIES FOR DOOR TAGS & DOOR SCHEDULE ON THIS MAIN & ACCENT: 6"x36",12"x24" OR 13"x20" (SIZE & SERIES MAY VARY). USE ONLY APPROVED MOP SINKS <br /> SHEET. TILE SERIES AND COLORS BY DALTILE, CROSSVILLE AND EUROWEST. VERIFY COLOR AND PATTERN 3. PROVIDE CEMENT BOARD BACKER OR EQUIVALENT AT ALL CERAMIC TILE <br /> 8. IF THE DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN PER INTERIOR DECOR DRAWINGS. LOCATIONS. <br /> OPEN POSITION OF 90 DEGREES, THE DOOR WILL TAKE AT LEAST 5 SECONDS TO MOVE TO A POSITION OF 12 <br /> DEGREES FROM THE LATCH. A. MUST BE PER McDONALD'S USA, LLC: STANDARDS FOR INTERIOR FLOOR TILE AND 4. ALL FINISH SURFACES OF WALL AND CEILING MATERIALS SHALL BE CLASS <br /> 9. DOORS, DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY APPROVED TILE LIST. B AND SHALL HAVE A FLAME SPREAD RATING OF 26 TO 75 AND A SMOKE <br /> WITH FOLLOWING: B. MUST BE NO LARGER THAN 6"x36", 12"x24" OR 13"x20". DENSITY OF 450 MAX. <br /> a.THE FLOOR OR LANDING SHALL NOT BE MORE THAN i/ INCH LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE 5. DECORATIVE MATERIALS SHALL BE FLAME RETARDANT AND MEET THE <br /> IN LEVEL BETWEEN 1/ INCH AND 1/ INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE-UNIT VERTICAL TO C. MUST MEET THE FOLLOWING: CRITERIA OF NEPA 701 . <br /> 2 UNITS HORIZONTAL. STATIC COEFFICIENT OF FRICTIONPER ASTM F1667-96 <br /> b.OPENING HARDWARE IS LOCATED BETWEEN 34" TO 44" ABOVE THE FLOOR. ( ) 6. DECORATIVE MATERIAL SHALL NOT CONCEAL EXITS, EXIT LIGHTS, ALARM <br /> c.D00R HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRED TIGHT LEVEL SURFACES: MINIMUM 0.50 DRY AND WET (MCDONALD'S STANDARD) STATIONS, HOSE CABINETS, AND EXTINGUISHER LOCATIONS. <br /> GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. DYNAMIC COEFFICIENT OF FRICTION (PER ANSI A137.1 2012) 7. VERIFY SS BACK SPLASH IS PRESENT AT ALL SINK LOCATIONS. <br /> LEVEL SURFACES: MINIMUM 0.5 DRY AND WET (MCDONALD'S STANDARD) 8. SEE REFLECTED CEILING PLAN FOR HEIGHTS & LAYOUTS. <br /> 4. TILE TRANSITION AND EDGE PROTECTION: 9. PROVIDE 1/2" PLYWOOD BEHIND INTERIOR FINISH BOARD FOR ALL <br /> WALL-MOUNTED MONITORS - VERIFY WITH DECOR DRAWINGS. <br /> A. TILE BASE (RESTROOM & SELF SERVE BEVERAGE BAR ONLY): PORCELAIN OR CERAMIC 3/8" FIRE NOTES <br /> COVE RADIUS BASE <br /> B. TILE EDGE PROTECTION (WALL TRANSITION): SCHLUTER-RONDEC-DB, SATIN ANODIZED <br /> 1. INTERIOR FINISH SHALL BE PROVIDED IN ACCORDANCE WITH TITLE 24 F- g <br /> ALUMINUM. V) 9 <br /> SECTION 804, AS FOLLOWS: CLASS I VERTICAL ENCLOSURES; CLASS IIQ 1 z m <br /> C. TILE CORNER PROTECTION (OUTSIDE CORNER): SCHLUTER-RONDEC-AE, SATIN ANODIZED CORRIDORS; CLASS III ROOMS. YCD <br /> ALUMINUM. 2. INTERIOR FINISH SHALL BE PROVIDED IN ACCORDANCE WITH TITLE 24, <br /> D. SEE INTERIOR DECOR DRAWINGS FOR ALL LOCATIONS. SECTION 804, AS FOLLOWS: CLASS I VERTICAL ENCLOSURES; CLASS II Q 0 W <br /> CORRIDORS; CLASS III ROOMS oLA i 5 <br /> BEFORE FINAL INSPECTION, REMOVE PROTECTIVE COVERINGS AND PERFORM FINAL CLEANING. 3. ALL DRAPES, HANGINGS, CURTAINS, DROPS AND ALL OTHER DECORATIVE m = o 0 <br /> MATERIAL TO COMPLY WITH FIRE CODE SECTION 11 03.3.3. m ~ a o <br /> 5. TILE CLEANER: DETERDEK, BY FILA SURFACE CARE PRODUCTS - NO SUBSTITUTIONS ALLOWED. Q z o N N <br /> CAN BE ORDERED BY EUROWEST, DALTILE, OR DIRECT FROM MANUFACTURER: FILA/DETEREK. O7z z � w <br /> POST INSTALLATION CLEANING REQUIRED ON ALL FLOOR TILE INSTALLTIONS PRIOR TO 0-) a w �q M <br /> ANY EXISTING FINISHES WHICH ARE TO REMAIN <br /> RESTAURANT TURN OVER. cn o x <br /> DURING CONSTRUCTION BECOME DAMAGED, G.C. J O X 0 <br /> APPLY CLEANER PER MANUFACTURER'S WRITTEN INSTRUCTIONS. TO REPLACE WITH MATCHING MATERIAL IN KIND. N Ld o ``' cn o <br /> REFERENCE: 2013 McDONDALDS PROJECT MANUAL - SECTION 09300 TILING INTERIOR. <br /> 6. GROUT COLOR AND MANUFACTURER AS INDICATED ON SHEET A1 .0 AND INTERIOR DECOR ALL SCHEDULES ON THIS SHEET ARE FOR REFERENCE ONLY. G.C. Z <br /> DRAWINGS. IS TO REFER TO APPROVED DECOR PACKAGE FOR FINAL FINISHES. W 5 ,9 2 <br /> 7. WATER-CLEANABLE, TILE-SETTING EPDXY (100% SOLIDS, INDUSTRIAL-GRADE) _ <br /> V) FINISH SCHEDULES & DETAILS <br />