Laserfiche WebLink
" c%k i� SAN JOAQUIN Environmental Health Department <br /> COUNTY Linda Turkatte , REHS , Director <br /> °gT �Foa�`�P Greotness grows here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> February 15 , 2019 <br /> Donlee Pump Company <br /> 2825 Railroad Ave . <br /> Ceres , CA 95307 <br /> Re : ER Vine Stockton SR0079994 , amended <br /> 4733 S . Hwy 99 <br /> Stockton , CA 95215 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to remove all existing penetrations in diesel turbine sump , replace with Bravo <br /> ( F -series ) split retrofit penetrations , and repair the diesel sump fiberglass wall on the underground <br /> storage tank ( UST) system at the above noted address . The permit has been approved with the <br /> following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209 ) 468- 3440 to arrange the following inspection appointments ( a <br /> 481­* hour notice is required for inspection appointments) . Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval . <br /> a . 24 - hour hydrostatic test ( or equivalent) on the diesel turbine sump ( in operating condition ) . <br /> b . If concrete will be broken near the tank , sumps , or piping , a secondary containment test <br /> must be performed on applicable components once concrete is poured in accordance with <br /> the manufacturer' s guidelines . <br /> Please be aware that the facility cannot receive fuel in the tank prior to the EHD <br /> inspection and approval . <br /> 4 . Secondary containment testing for the diesel turbine sump is required six months after repairs . <br /> Provide 48 hours notification to the EHD when this test is scheduled . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 - 3420 1 F 209 464 -0138 1 www. sjcehd . com <br />