My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:27:47 AM
Creation date
8/18/2020 11:08:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax; (209) 468-3433 Web: www.s'gov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />7 -ELEVEN INC #35355 <br />3202 W Hammer Ln, Stockton <br />February 08, 2019 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />320 <br />CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br />prevention. <br />The 87 flapper used as the overfill prevention system is not currently functional on the 87 UST. According to a work <br />order dated 7/3/18, the "87 fill drop tube flapper is stuck open" and "construction will need to return ... and replace <br />drop tube." No work orders were indicating this flapper was replaced. No permits have been obtained from EHD for <br />flapper/drop tube replacement. The overfill prevention test report dated 9/18/18 states the 87 flapper could not be <br />tested because it was stuck and could not be removed. The designated operator inspection reports state the 87 <br />flapper was tested on 10/26/18, but no work orders or test results were found on site. Immediately repair or replace <br />the failed component by a properly licensed, trained, and certified contractor under permit and inspection of the <br />EHD. If proof that the site has a functioning overfill prevention method in place cannot be provided immediately, <br />there is a possibility that the 87 UST system may be red tagged to prevent fuel inputs. <br />Overfill prevention testing has not been conducted for the 87 flapper. This testing was required to be conducted by <br />October 13, 2018. Immediately schedule this testing and provide 48 hours notification to the EHD. Ensure all future <br />testing is conducted within required time frames. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by March 10, 2019. <br />"The monitoring system certification was conducted on 2/6/19. The sumps and UDCs were visually inspected <br />by the EHD, but the testing was not witnessed by EHD. The paperwork inspection was conducted today <br />(2/8/19). The technician, Michael Deatherage, did not have proof of certifications for VMI Tanknology Tester or <br />Franklin Fueling Phase I (spill bucket). Jesus Saldivar with Tanknology called on 2/7/19 to notify EHD that he <br />had conducted the leak detector and spill container testing on 2/6/19; his certifications were confirmed. <br />Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate ($152). To schedule an <br />appointment, please call (209) 468-3420. <br />Documents provided: Return to Compliance Certification form, schedule of free CUPA classes <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: February 08, 2019 <br />Inspector: <br />Inspector Phone: <br />` Printed Name and Title: <br />STACY RIVERA, Senior REHS <br />(209) 468-3440 <br />Jesse Singh, Manager <br />FA0001817 PR0231129 SCO01 02/08/2019 <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.