Laserfiche WebLink
FA0001817 PR0231129 SCO01 02/08/2019 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax; (209) 468-3433 Web: www.s'gov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility <br />Name: <br />Facility Address: <br />Date: <br />7 -ELEVEN <br />INC #35355 <br />3202 W Hammer Ln, Stockton <br />February 08, 2019 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br />-The designated operator inspection reports state overfill prevention testing was conducted on the 87 flapper on <br />10/26/18. No work orders or test results were available for this date. <br />These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br />observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br />site and submit copies to the EHD. <br />This is a repeat violation, Class II. <br />205 <br />CCR 2712(1), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br />An approved copy of the current response plan was not available for inspection. The response plan on site was <br />dated 2011 with outdated information. The response plan in CERS is dated 2017. A copy of this plan shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />301 <br />HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br />The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. The <br />underground storage tank system shall be operated to prevent unauthorized releases. Immediately provide <br />approved secondary containment for the filters under permit and inspection by the EHD. <br />This is a Class II violation. <br />314 <br />HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br />The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br />containment shall be provided for all single -walled UST components. Immediately provide approved secondary <br />containment for the filters under permit and inspection by the EHD. <br />This is a minor violation. <br />FA0001817 PR0231129 SCO01 02/08/2019 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />