Laserfiche WebLink
OPW Installation,Operation, and Maintenance Manual, Page 78 Executive Order VR-102-0 <br /> STEP 17:INSTALL WARNING PLATE <br /> Slide the tie wrap over the warning <br /> plate ears and position warning <br /> plate against riser pipe approxi- I <br /> mately 1"below the adaptor. <br /> Tighten the tie wrap securely. The <br /> valve is now fully installed and in <br /> operating position. <br /> STEP 18:VALVE REMOVAL <br /> The valve can be removed for tank <br /> leak testing,inspection,etc.,by <br /> removing the Rotatable Product <br /> Adaptor,the 4"nipple,and the Jack Screw Kit. Figure 17 <br /> Reinstall per the above instructions. <br /> STEP 19:ELECTRONIC LIQUID LEVEL MONITORING 4um,lxiurt 'GUN' <br /> +.eda-t tso-A' <br /> 'o <br /> If <br /> a- <br /> If an electronic level monitor is installed,it must be tali- r a.P eu is S_e, <br /> brated to match the to of the 61 SO valve body,which %Iamfa`t"'e oax <br /> P '%IPG LILT�}- <br /> must correlate with 95%of the actual tank Capacity. I %MlAIDa Y"-"a' <br /> PREVENTATIVE MAINTENANCE <br /> Product Identification <br /> Annually,inspect the flapper in the 61 SO to see that it is <br /> open by looking down the drop tube opening. Test the <br /> 61 SO drop tubeseals with CARB procedure TP-201.1 D. <br /> If the drop tube seal passes testing,no further mainte- <br /> nance is required. If the drop tube fails testing,replace D <br /> the drop tube seal with OPW PIN:H 11931 M for 4" ?, <br /> Tubes. Re-test the 61 SO drop tube with CARBproce- <br /> dure TP-201.1 D. If this does not correct the leak the 2p19 <br /> 61 SO needs to be replaced. <br /> CAUTION: Do not insert any foreign object into drop EALTH <br /> tube if flapper is in the closed position.For example NMEt`1TA1 H <br /> a tank level measuring stick. This will damage the EN�f IRD ENT <br /> valve and void the Warranty. ALWAYS check flapper pEPARTM <br /> location before"sticking"the tank. If flapper is in <br /> the closed position the tank is either over filled and <br /> you need to wait until the liquid level goes down or <br /> the 61SO is damaged and needs to be replaced. <br /> 6130 Performance Specifications: <br /> This Overfill Prevention Valve has been manufactured <br /> and tested to,and met,the following California specifi- <br /> cations. Performance Requirement:Leak rate to be less <br /> than orequal to 0.17 CFH @ 2.0"W.C. <br /> Torque Specification: <br /> Self-Clinching Studs,50 6-8 UN thread, 11.5 ft-lbs mini- <br /> mum to 13.5 ft-lbs maximum. <br /> IMPORTANT:Leavethese installation instructions <br /> and maintenance procedures with the at <br /> opera- <br /> tor. <br />