COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YETTNER
>
252
>
2200 - Hazardous Waste Program
>
PR0539093
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2020 1:09:37 PM
Creation date
8/24/2020 10:21:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0539093
PE
2220
FACILITY_ID
FA0010877
FACILITY_NAME
PAN PACIFIC RV CTR
STREET_NUMBER
252
Direction
W
STREET_NAME
YETTNER
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19306051
CURRENT_STATUS
01
SITE_LOCATION
252 W YETTNER RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
YMoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PAN PACIFIC RV CTR 252 W YETTNER RD, FRENCH CAMP September 06, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 105 CCR 66262.34(d)(2)No emergency coordinator. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 110 CCR 66262.40(a) Failed to keep signed copy of manifests from the designated facility for three years. <br /> Copies of uniform manifests for the disposal of hazardous waste for September15, 2015 to September 6, 2018 <br /> were not found on site. <br /> Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and all receipts <br /> used in a consolidated manifesting procedure on site for three years and have them readily available for review. <br /> Provide all records of hazardous waste from Sept 15, 2015 to Sept 6, 2018, including used oil and unpunctured oil <br /> filters, maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br /> Copies of consolidated manifest receipts for the disposal of hazardous waste for September15, 2015 to September <br /> 6, 2018 were not found on site. <br /> Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and all receipts <br /> used in a consolidated manifesting procedure on site for three years and have them readily available for review. <br /> Provide all records of hazardous waste from Sept 15, 2015 to Sept 6, 2018, including used oil and unpunctured oil <br /> filters, maintain them on site, and submit copies to the EHD. <br /> This is a minor violation. <br /> FA0010877 PR0539093 SCO01 09/06/2018 <br /> EHD 22-01 Rev.10/31/2017 Page 4 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.