Laserfiche WebLink
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PAN PACIFIC RV CTR 252 W YETTNER RD, FRENCH CAMP September 06, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 HSC 25144.6(b)Failure to properly manage reusable soiled textile materials. <br /> Violation found:facility has no record of industrial laundry receipts for shop rags.The facility must provide three <br /> years records for laundry services. Provide receipts for Sept 15, 2015 to Sept 6, 2018. <br /> This is a minor violation. <br /> 602 CCR 66262.34(e)(1)(B)Stored satellite accumulated waste on site longer than one year or 180 days after fill date. <br /> One 55 gallon container of used oil is stored on site for unknown length of time and one 55 gallon container of <br /> unpunctured used oil filters is stored on site since Feb 4, 2016. <br /> Satellite accumulated waste shall not be stored on site for more than 180 days after the container was filled, or a <br /> total of one year,whichever comes first. <br /> Immediately contact a licensed hazardous waste hauler to dispose of this waste under manifest and submit a copy <br /> of the manifest to the EHD. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> The 55 gallon container of unpunctured used oil filters,which is 1/3 full, is missing the words Hazardous Waste, <br /> name and address of generator, hazardous properties, and physical state. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by October 5, 2018. <br /> Waste streams observed: Used oil, unpunctured used oil filters, and oily shop rags. <br /> Note: Oily absorbent may be a hazardous waste, usually due to toxicity. Aerosol cans that are not empty may <br /> be a hazardous waste usually due to ignitability. The site uses absorbent to cleanup spills. I observed several <br /> FA0010877 PR0539093 SCO01 09/06/2018 <br /> EHD 22-01 Rev.10/31/2017 Page 5 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />