My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:19:08 PM
Creation date
8/25/2020 12:39:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231342
PE
2361 - UST FACILITY
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1301 W KETTLEMAN LN LODI 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205-6232 <br /> Telephone: (209 ) 468-3420 Fax : (209 ) 468-3433 Web: www. sjgov . org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> FLAMES LIQUOR 1301 W KETTLEMAN LN LODI March 28 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632 ( d ) ( 1 ) , 2634 (d ) Failed to have an approved UST monitoring plan . <br /> The monitoring plans left UDC sensor manufacturer and model blank . The monitoring plan must be uploaded to the <br /> California Environmental Reporting System ( CERS) . Immediately log into CERS , make the necessary changes , and <br /> submit for review by the EHD . <br /> This is a minor violation. <br /> 204 CCR 2712 ( i ) Current monitoring plan approved by the EHD not found on site . <br /> An approved copy of the monitoring plans were not available for inspection . A copy of these plans shall be accessible <br /> on site at all times . Immediately locate and retain a copy on site . <br /> This is a minor violation. <br /> 209 CCR 2716 ( a-e ) Failure to conduct the designated UST operator visual inspection at least once every 30 days . <br /> A designated operator inspection was performed on January 11 , 2019 and the next inspection was performed on <br /> February 11 , 2019 , 31 days later. The designated operator visual inspections shall be conducted within 30 days or <br /> less of the previous inspection . Ensure that all designated operator inspections are performed within the required time <br /> frames . <br /> The designated operator failed to check and note all required items on the visual inspection reports . <br /> -The 10/18/ 18 inspection report incorrectly stated overfill testing was not conducted on time , did not mention the ' no' <br /> for overfill testing in Section III , and left Section V blank. <br /> -The 1 / 11 / 19 inspection report left the sump sensor location question blank and both tank and line tightness testing <br /> questions blank . <br /> -The 2/ 11 / 19 inspection report left the tank and line tightness testing questions blank. <br /> -The 3/ 11 / 19 inspection report left Section V blank . <br /> During the visual inspection , the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designated operators <br /> performing visual inspections at this facility are including all of the required information on the reports . <br /> This is a minor violation. <br /> Overall Inspection Comments : <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , by April 27 , 2019 . <br /> Starting September 1 , 2018 , all in -office CERS help will be provided at EHD hourly rate ($ 152 ) . To schedule an <br /> appointment , please call (209 ) 468 -3420 . <br /> FA0000392 PR0231342 SCO01 03/28/2019 <br /> EHD 23-01 Rev. 09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.