COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:19:08 PM
Creation date
8/25/2020 12:39:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231342
PE
2361 - UST FACILITY
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1301 W KETTLEMAN LN LODI 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205-6232 <br /> Telephone: (209 ) 468-3420 Fax : (209 ) 468-3433 Web: www. sjgov . orq/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Phone: Date : <br /> FLAMES LIQUOR 209 334-3233 March 28 2019 <br /> Facility Address : CERS ID: <br /> 1301 W KETTLEMAN LN LODI CA 95242 10180585 <br /> Inspection Contact: Title: Phone: <br /> Bikram Sodhi I Mana er 209 334-3233 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> Consent For: I Consent Given By : <br /> 0 Inspection Z Photos E9 Samples Bikram Sodhi Mana er <br /> Service Technician Onsite: Exp. Date : Designated Operator: Exp. Date : <br /> Dave Winkler 01 /21 /2020 Alex Jabbari 10/01 /2020 <br /> Service Technician Manufacturer's Training <br /> VR , 02/08/20 ; VMI , 11 /29/ 19 ; TT 3/31 /20 , SB , 11 /09/ 19 <br /> CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees ❑ V ❑ R ❑ COS <br /> 102 HSC 25284(a) (3) (A)/ No written agreement between tank owner and tank operator to monitor the tank system ❑ V ❑ R ❑ COS <br /> (B) <br /> 103 HSC 25292 . 21 25299 . 30 Failure to submit and maintain complete and current financial responsibility documents ❑ V ❑ R ❑ COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ❑ V ❑ R ❑ COS <br /> 105 CCR 2632 (d) ( 1 ) , Failed to have an approved UST monitoring plan ■ V ❑ R ❑ COS <br /> 2634(d) <br /> 106 CCR 2632 (d) (2) , Failed to have an approved UST response plan ❑ V ❑ R ❑ COS <br /> 2634(e) <br /> 107 CCR 2632(d) ( 1 ) (C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑ V ❑ R ❑ COS <br /> 108 CCR 2637 , 2638(e) , Failed to notify the EHD 48 hours prior to conducting testing ❑ V ❑ R ❑ COS <br /> 2643(g ) <br /> 109 CCR 2637 (a-d) , 2712 Failed to test secondary containment, or failed to maintain test records for 36 months ❑ V ❑ R ❑ COS <br /> 110 CCR 2637 (e) , 2637 (f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test ❑ V ❑ R ❑ COS <br /> 111 CCR 2638(a) & (b) , Failed to test monitoring and leak detection equipment annually ❑ V ❑ R ❑ COS <br /> 2641 Q) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance ❑ V ❑ R ❑ COS <br /> 113 CCR 2638 (c) , 2638 (d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test ❑ V ❑ R ❑ COS <br /> 114 CCR 2636(f) (3) 1 No 0 . 1 gph annual line integrity test for pressurized piping , or within 30 days after repair ❑ V ❑ R ❑ COS <br /> 2643(c) (3) <br /> 115 CCR 2715 (a) ( 1 ) (B) , " Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days ❑ V ❑ R ❑ COS <br /> 2715(a) (3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification ❑ V ❑ R ❑ COS <br /> 117 CCR 2663 , 2712 (b) (6) Failure to comply with tank lining , recordkeeping , and inspection requirements ❑ V ❑ R ❑ COS <br /> 118 CCR 2715 (a) ( 1 ) (A) , Failure to submit the " Underground Storage Tank Statement of Understanding and Compliance Form" ❑ V ❑ R ❑ COS <br /> 2715(a) (2) <br /> 119 HSC 25299 (a) (8) , Documents were falsified or misrepresented ❑ V ❑ R ❑ COS <br /> 25299 (b) (7) <br /> 120 CCR 2635 (d) Failed to submit UST Certification of Installation/Modification ❑ V ❑ R ❑ COS <br /> 121 CCR 2712 (f) Failed to submit a written response within 30 days of receiving an inspection report ❑ V ❑ R ❑ COS <br /> FA0000392 PR0231342 SC001 03/28/2019 <br /> EHD 23-01 Rev. 09/22/16 Page 1 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.