Laserfiche WebLink
REVISIONS BY <br /> GENERAL NOTES <br /> I .- ON-SITE VERIFICATION OF ALL DIMENSIONS AND DETAILS SHALL BE THE 8.- AVOID DAMAGE TO EXISTING FACILITIES THAT ARE TO REMAIN LONG-TERM THERMAL RESISTANCE (LTTR) VALUE ( 5.- GLASS GLAZING : USE TEMPERED GLASS IN METAL FRAMES AND FIRE <br /> RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH UNDISTURBED. ANY DAMAGE WHICH HAS OCCURRED DUE DEMOLITION <br /> SUBCONTRACTOR FOR HIS INDIVIDUAL WORK. THE OWNER OR ARCHITECT CAN/ULC-5770) : RATED GLASS AND FRAMES IN FIRE RATED DOORS. COMPLY WITH DOOR <br /> SHALL BE NOTIFIED IF ANY DISCREPANCIES ARE FOUND PRIOR TO AND CLEARING WORK SHALL BE PAID FOR BY THE CONTRACTOR. MINIMUM 5.5 F-HR-Sci.Ft./BTU/ INCH AT 75 DEG. F. MANUFACTURERS WRITTEN INSTRUCTIONS. <br /> COMMENCING ANY WORK. THE RESPONSIBILITY FOR WORK COMPLETED <br /> WITHOUT PROPER NOTIFICATION SHALL BE BORN BY THE INDIVIDUAL 9.- COMPLY WITH ALL FEDERAL, STATE, AND LOCAL SAFETY ORDERS, e.- THICKNESS 5 INCHES UNIFORM UNDER ALL G.- DOOR LOUVERS: FABRICATE FROM COLD ROLLED STEEL SHEET , <br /> CONTRACTOR INVOLVED WITH THE WORK. REGULATIONS, AND STANDARDS. SPR MODEL 800 A I BY AIR LOUVERS , INC. FACTORY PRIME TO RECEIVE FINISH <br /> 2.- THE CONTRACT DOCUMENTS INDICATE THE EXTENT AND APPROXIMATE 10.- TAKE ALL NECESSARY STEPS TO CONTROL NOISE AND DUST. COLOR AS SELECTED BY ARCHITECT. <br /> PLACE INSULATION OVER CLEAN ROOF DECK. INSTALL INSULATION IN <br /> LOCATION OF ELEMENTS OF THE BUILDING AND SITE OF WORK TO BE SPECIFIED THICKNESS. INSTALL ADDITIONAL THICKNESS AT CRICKETS AS 7.- ACCESS DOORS : MILCOK OR EQUAL ; 14 GAUGE STEEL PANEL, STYLE <br /> PERFORMED. ALL CONDITIONS, LOCATIONS, DEVICES AND ELEMENTS I I .- THE SITE IS TO BE LEFT IN A RELATIVELY FLAT, ROUGHLY GRADED REQUIRED TO MEET THE REQUIREMENTS INDICATED ON THE DRAWINGS. DW AT WALLS AND CEILINGS, FACTORY PRIME PAINTED. SIZE AS <br /> SHALL BE VERIFIED PRIOR TO COMMENCING THE WORK. CONDITION AND FREE OF RUBBISH, TRASH, AND DEBRIS. INSTALL NO MORE THAN CAN BE COVERED IN SAME DAY. STAGGER ALL INDICATED ON DRAWINGS. <br /> 3.- ALL WORK PERFORMED IN CONNECTION WITH THESE CONTRACT JOINTS WHEN MULTIPLE LAYERS OR TYPES OF INSULATION ARE BEING <br /> INSULATED. 8.- FABRICATE UNITS SQUARE, TRUE AND FREE FROM DEFECTS. DRESS, ce' <br /> DOCUMENTS SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND SITE WORK = U M <br /> ORDINANCES IN EFFECT AT THE TIME OF CONSTRUCTION. THIS PROJECT FILL AND SAND EXPOSED SURFACES, BODYFUTTY HOLES AND Z O <br /> SHALL COMPLY WITH TITLE 24, 2019 CBC, CMC, CPC, CEC, CFC, AND CGC. 4.- ACCESSORIES : IMPERFECTIONS AND APPLY A UNIFORM COAT OF MANUFACTURERS II-_ <br /> I .- SUBSURFACE CONDITIONS: A SOILS INVESTIGATION WAS PREPARED V z z <br /> STANDARD PRIME COAT OF PAINT TO ALL SURFACES READY TO RECEIVE � W <br /> 4.- NO DRAINAGE IS ALLOWED ACROSS OR ONTO ADJACENT PROPERTY. FOR THE SITE. CODE MINIMUMS WERE USED IN PREPARING THE a.- NON-REINFORCED OR REINFORCED TPO FLASHING, PIPE BOOT AND FINISH PAINTING. Q � . Z W <br /> CONSTRUCTION DOCUMENTS. ALL WORK SHALL COMPLY WITH THE RULES FLASHING, CLAMPING RINGS, ETC. : USE ROOFING MEMBRANE PROVIDED V O J J <br /> 5.- THERE WILL BE NO ON-SITE WATER RETENTION ON SITE EXCEPT AS AND REGULATIONS OF LOCAL AND STATE AGENCIES HAVING AND RECOMMENDED BY MANUFACTURER. 9.- INSTALL DOORS AND FRAMES IN ACCORDANCE WITH ANSI A250.8 AND Z 0 J a, <br /> APPLICABLE. JURISDICTION. 0 W <br /> UL 752 AS APPLICABLE. SET FRAMES LEVEL AND PLUMB, AND BRACE C9 V <br /> b.- FLASHING METAL : 0.023 INCH THICK GALVANIZED STEEL LAMINATED TO ADEQUATELY TO PREVENT DAMAGE OR DISTORTION. FIT DOORS I- Z vi <br /> G.- PROVIDE 2% MIN, SLOPE AWAY FROM BUILDING FOR 5 FT. AT SIDES AND 2.- SITE DEMOLITION: REMOVE AND LEGALLY DISPOSE OF ALL DEBRIS AND 0.020 INCH THICK ROOFING MEMBRANE IN WHITE COLOR USED FOR ACCURATELY IN FRAMES. MAXIMUM DIAGONAL DISTORTION IS 1 / I G INCH V is <br /> 10 FT. AT FRONT. DEMOLISHED MATERIALS OFF-SITE. USE ALL MEANS NECESSARY TO FLASHING AND EDGE METAL DETRAINING AS FURNISHED BY THE MEASURED WITH STRAIGHT EDGE, CORNER TO CORNER. _ 2 W <br /> PROTECT EXISTING OBJECTS TO REMAIN, INCLUDING BURIED UTILITIES. MEMBRANE MANUFACTURER. w m > <br /> 7.- TYPICAL DETAILS SHOWN IN THESE DOCUMENTS SHALL APPLY IN ALL PROVIDE ANY MEANS REQUIRED TO MAINTAIN DUST CONTROL AND 10.- FRAMES SHALL BE ANCHORED TO STRUCTURE WITH ANCHORS F" Q-i 0 <br /> SIMILAR CASES UNLESS SPECIFICALLY NOTED OTHERWISE. WHERE NO PREVENT THE SPREAD OF DUST NUISANCE TO THE PUBLIC AND c.- MEMBRANE FAPPROPRIATE FOR USE WITH TYPE OF ADJACENT CONSTRUCTION AND PER FASTENERS AND DISCS: USE MECHANICAL FASTENERS co 0� a W <br /> DETAILS IS SHOWN , CONSTRUCTION SHALL BE AS INDICATED FOR OTHER m <br /> APPROVED BY THE ROOFING SYSTEM MANUFACTURER INCLUDING COVER Z W <br /> SIMILAR WORK AND, OR APPLICABLE INDUSTRY PRACTICE. NEIGHBORS. MANUFACTURER'S RECOMMENDATIONS. ANCHORAGE SHALL SECURELY <br /> BOARD AND INSULATION MANUFACTURERS. 0 Z p <br /> FASTEN FRAMES TO WALL CONSTRUCTION. USE A MINIMUM OF THREE � 0 <br /> 8.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COORDINATION OF 3.- EARTHWORK: PROVIDE APPROVED BORROW SOIL MATERIALS MEETING ANCHORS AT EACH DOOR JAMB. <br /> INSTALLATION, INSPECTION, AND FINAL APPROVAL OF ALL UTILITIES. ASTM D2487 . PROVIDE DRAINAGE FILL MATERIAL MEETING ASTM D 448. d.- MEMBRANE BONDING ADHESIVE AT VERTICAL SURFACES: 0 <br /> PROVIDE BURIED WARNING AND IDENTIFICATION TAPE FOR BURIED MANUFACTURER APPROVED LOW VOC BONDING ADHESIVE TO MEET I I .- PREP DOORS FOR ALL FINISH HARDWARE. OBTAIN TEMPLATES FROM Vrz <br /> 9.- CONTRACTOR TO VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND UTILITY LINES. VERIFY THAT SOILS AND COMPACTION COMPLY WITH CODE CALIFORNIA AIR RESOURCES BOARD OR LOCAL AIR POLLUTION CONTROL HARDWARE MANUFACTURER AND CONFIRM TYPE, LOCATION AND SPECIAL W V <br /> METHODS OF CONSTRUCTION PRIOR TO START OF ANY WORK. NOTIFY MINIMUMS OR WITH SPECIFIED REQUIREMENTS OF SOILS INVESTIGATION / AIR QUALITY MANAGEMENT DISTRICT REGULATIONS. REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING. O _ <br /> ARCHITECT OF ANY DISCREPANCIES. REPORT IF PROVIDED. <br /> e.- TERMINATION BAR: EXTRUDED ALUMINUM BAR 0.08 INCH THICK BY 1 12.- FINAL ADJUSTMENTS: ADJUST DOORS FOR SMOOTH AND BALANCED p W <br /> 10.- IT IS NOT THE INTENT OF THESE CONTRACT DOCUMENTS TO 4.- SITE DRAINAGE: PROVIDE LABOR, MATERIALS, TOOLS, AND EQUIPMENT INCH WIDE. DOOR MOVEMENT. CHECK AND ADJUST OPERATING FINISH HARDWARE. <br /> SEPARATE THE WORK INTO SUBTRACTED DIVISIONS. IT SHALL BE THE NECESSARY TO EXCAVATE, INSTALL, CONSTRUCT AND BACKFILL STORM <br /> RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DIVIDE THE WORK DRAINAGE SYSTEM, INCLUDING PIPIES, PIPE TRENCHES, AND ASSOCIATED f.- MEMBRANE CLEANING SOLUTION: MANUFACTURER APPROVED OR <br /> AND ORGANIZE ALL WORK AS REQUIRED TO COMPLETE THE WORK AS APPURTENANCES AS SHOW IN THE CONSTRUCTION DOCUMENTS. RECOMMENDED. HARDWARE <br /> INDICATED BY THESE DOCUMENTS. 1. ALL FINISH HARDWARE FOR COMPLETE WORK SHALL BE FURNISHED AND INSTALLED IN ACCORDANCE <br /> cg.- SEALANTS: SOLVENT-BASED ETHYLENE PROPYLENE SEAM CAULK WITH DRAWINGS AND SPECIFICATIONS. QUANTITIES LISTED IN ANY INSTANCE ARE FOR THE <br /> I I .- ALL SITE WORK SHALL COMPLY WITH THE STATE OF CALIFORNIA TITLE 5.- PORTLAND CEMENT CONCRETE PAVING: READY-MIXED CONCRETE APPROVED BY ROOFING SYSTEM MANUFACTURER. CONTRACTOR'S CONVENIENCE ONLY AND ARE NOT GUARANTEED. ITEMS NOT SPECIFICALLY MENTIONED <br /> 24, THE AMERICANS WITH DISABILITIES ACT ( ADA ) AND ALL APPLICABLE PRODUCTS SHALL COMPLY WITH ASTM C 94. ALL CONCRETE WORK SHALL BUT NECESSARY TO COMPLETE THE WORK FURNISHED, MATCHING IN QUALITY AND FINISHED,THE <br /> ITEMS SPECIFIED. <br /> CODES, ORDINANCES, AND ZONING REGULATIONS AS APPLICABLE. COMPLY WITH THE AMERICAN CONCRETE INSTITUTE SPECIFICATIONS AND h.- ALL-PKOPUSE SEALANT (MASTIC) : SINGLE COMPONENT, HIGH-SOLIDS <br /> MANUAL OF STANDARD PRACTICE. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER OPERATION AND FITTING OF HARDWARE <br /> CONTENT, AND GUN GRADE APPROVED BY MEMBRANE MANUFACTURER. IN LOCATIONS SPECIFIED. THE CONTRACTOR MUST SUPPLY A ROOM UNDER LOCK AND KEY TO <br /> 12- THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE STORE ALL FINISH HARDWARE UNTIL INSTALLATION 15 MADE.THE HARDWARE SUPPLIER MUST MARK <br /> LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO THE G.- WATER SYSTEMS: COMPLY WITH THE REQUIREMENTS OF THE UTILITY EACH ITEM OF HARDWARE AS TO DESCRIPTION AND LOCATION OF INSTALLATION IN ACCORDANCE <br /> COMMENCEMENT OF WORK. HE SHALL BE RESPONSIBLE FOR THE i.- WALKWAY PADS: 0. 130 INCH THICK HEAT-WELDABLE MATERIAL AS WITH APPROVED HARDWARE SCHEDULE. EXPOSED SURFACES OF HARDWARE SHALL BE COVERED <br /> SUPPLYING WATER AND STANDARDS OF AUTHORITY FOR FIRE SUPPLIED BY MEMBRANE MANUFACTURER, COLOR WHITE. VERIFY AND WELL PROTECTED DURING INSTALLATION, SO AS TO AVOID DAMAGE TO FINISHES. <br /> LOCATION AND PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF PROTECTION. 3. PROVIDE HARDWARE FOR FIRE-RATED OPENINGS IN COMPLIANCE WITH REQUIREMENTS OF NFPA 80. <br /> CONSTRUCTION, AND SHALL NOTIFY UTILITY COMPANIES AT LEAST 48 MANUFACTURER'S STANDARDS FOR WALKWAY PAD DESIGN AND THIS REQUIREMENT TAKES PRECEDENCE OVER OTHER REQUIREMENTS FOR SUCH HARDWARE. <br /> HOURS IN ADVANCE OF ANY CONSTRUCTION. TELEPHONE NUMBER FOR 7.- SEWERAGE: ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH SLIP-RESISITANT PRIOR TO PROCUREMENT. 4. HARDWARE SUPPLIER WILL PROVIDE APPROVED SCHEDULED AND PAPER TEMPLATES TO VARIOUS <br /> UNDERGROUND SERVICE ALERT ( USA ) 1 -800-227-2400. JURISDICTIONS STANDARD SPECIFICATIONS. J.- SAFETY ZONE MARKINGS : ROOFING MANUFACTURER'S 12 INCH WIDE OTHER SUPPLIERS FOR DOOR AND FRAME PREPARATION FOR HARDWARE. <br /> YELLOW COVERSTKIP CONSISTING OF 30 MIL THICK NON-REINFORCED 5. EACH ITEM OF HARDWARE SHALL BE PACKAGED SEPARATELY WITH ALL NECESSARY SCREWS, BOLTS, <br /> 13.- A CLEAR AND LEVEL LANDING SHALL BE PROVIDED ON EACH SIDE OF TAMPIN5, KEYS AND INSTALLATION TEMPLATES. DELIVER PACKAGES, CLEARLY IDENTIFIED, WITH <br /> AN EXIT DOOR. THE LANDING SHALL BE 48 INCHES IN LENGTH WHERE THE 8.- PAVEMENT MARKINGS: USE FAST DRYING, 100% ACRYLIC WATERBORNE TPO FLASHING LAMINATED TO A NOMINAL 30 MIL THICK, FULLY CURED HEADING NUMBER AS APPROVED ON HARDWARE SCHEDULE. <br /> DOOR SWINGS AWAY FROM THE LANDING, AND GO INCHES IN THE LENGTH PAINT SPECIFICALLY FORMULATED FOR APPLICATION TO ASPHALT AND SYNTHETIC RUBBER PRESSURE SENSITIVE ADHESIVE. G. INSTALL EACH HARDWARE ITEM IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS <br /> IN THE DIRECTION OF THE DOOR SWING AS MEASURED AT RIGHT ANGLES CONCRETE VEHICULAR TRAFFIC SURFACES. COMPLY WITH 'GARB' RULES. k.- EXPOSED FASTENER COVER: HEAT-SHRINK TUBING, THIN-WALL, AND RECOMMENDATIONS AND LOCATE IN ACCORDANCE WITH Dhl RECOMMENDED LOCATIONS. SET ITEMS <br /> TO THE PLANE OF DOOR IN THE CLOSED POSITION. LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT 5UB- <br /> FLEXIBLE, POLYOLEFIN TUBING. 5TRATE, AS NECESSARY, FOR A SECURE INSTALLATION. SPACE FASTENERS AND ANCHORAGE AS INDI- <br /> 9.- IRRIGATION: PROVIDE A COMPLETE IRRIGATION SYSTEM WITH CATED OR IN ACCORDANCE WITH INDUSTRY STANDARDS. Z <br /> 14.- NO WORK SHALL COMMENCE AT THE PROJECT SITE BEFORE A COMPLETE COVERAGE USING APPROPRIATELY SIZED SCHEDULE 40 PVC I.- WOOD NAILER5 : PRESSURE TREATED. 7. MAKE FINAL ADJUSTMENT AND CHECK OF HARDWARE DURING THE WEEK IMMEDIATELY PRIOR TO O <br /> BUILDING PERMIT IS FULLY EXECUTED AND AVAILABLE FOR POSTING AT PIPE. PROVIDE ALL FITTINGS, NIPPLES, SPRINKLER HEADS, AUTOMATIC ACCEPTANCE. CLEAN AND RELUBRICATE OPERATING ITEMS AS NECESSARY, TO RESTORE PROPER <br /> THE JOB SITE. CONTROLLERS, CONTROL VALVES, QUICK-COUPLING VALVES, GATEFUNCTIONING AND FINISH OF HARDWARE AND DOORS. MAKE FINAL ADJUSTMENT OF LOCK5ET5 AND <br /> 5.- MEMBRANE FLASHING : FLASH ALL VERTICAL SURFACES WITH THE CLOSURES TO COMPENSATE FOR OPERATION OF HEATING AND VENTILATION SYSTEMS UNDER <br /> 15.- THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE <br /> VALVES, VALVE BOXES, SLEEVE MATERIAL, AND CONTROL WIRE AS REINFORCED MEMBRANE. USE BONDING ADHESIVE ON VERTICAL THE SUPERVISION OF MANUFACTURER'S REPRESENTATIVE.CONTRACT DOCUMENTS AND THE EXISTING FIELD CONDITIONS, AND NECESSARY FOR PROPER OPERATION. SURFACES MORE THAN 12 INCHES HIGH SUCH WALLS, CURBS, AND PIPES. 8. LUBRICATE ALL MOVING PARTS WITH GRAPHITE-TYPE LUBRICANT, UNLESS OTHERWISE RECOMMENDED U <br /> SHALL IMMEDIATELY REPORT TO THE ARCHITECT ANY ERROR, BY MANUFACTURER. REPLACE ALL HARDWARE WHICH CANNOT BE LUBRICATED AND ADJUSTED TO - <br /> 10.- LANDSCAPING: PROVIDE ALL TURF, SHRUBS AND TREES AND PANTING G.- WALKWAYS : HEAT WELD WALKWAY PADS AS RECOMMENDED BY THE OPERATE FREELY AND SMOOTHLY. <br /> INCONSTANCY, OR OMISSION HE MAY DISCOVER. THE CONTRACTOR MATERIALS AS SHOWN IN THE CONSTRUCTION DOCUMENTS. PROVIDE <br /> SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT MANUFACTURER IN THE LOCATIONS INDICATED ON DRAWINGS. <br /> APPROVED CONTRACT DOCUMENTS OR WHERE REQUIRED, APPROVED TOPSOILCONDITIONERS PLANTING SOIL MIXTURE, PLANT FERTILIZER, -SEALANTS AND CAULKING <br /> SHOP DRAWINGS, PRODUCT LITERATURE, DATA, SAMPLES OR MULCH, STAKES, WATER, AND HERBICIDES AS REQUIRED FOR EACH TYPE 7.- SAFETY ZONE MARKINGS : INSTALL SAFETY ZONE MARKINGS AS I. PROVIDE NON-SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL SPECIFICATIONS W <br /> INSTALLATION INSTRUCTIONS. OF PLANT. LANDSCAPING SHALL BE WARRANTED FOR ONE YEAR. RECOMMENDED BY THE MANUFACTURER IN THE LOCATIONS INDICATED TTS-1 543 OR F5 TT-5-230 TYPE"II", CLA55"A". PROVIDE ACOUSTICAL SEALANT WHICH C_ <br /> DEFECTIVE OR DEAD PLANTS SHALL BE REPLACED. SHALL BE NON-HARDENING, NON-DRYING SYNTHETIC RUBBER SEALING COMPOUND WITH MIN.- f1 <br /> ON DRAWINGS. IMUM 90%SOLIDS. USE AT ALL INTERIOR JOINTS AT INNER SECTIONS BETWEEN PLANES. 1 J <br /> I G.- DUE TO THE DIFFICULTY OF ANTICIPATING EVERY AS-BUILT CONDITION AROUND DOOR AND WINDOW FRAMES PRIMER SHALL BE MADE OR RECOMMENDED BY SEALANT <br /> WHICH MAY EXIST IN CONNECTION WITH THE EXISTING WORK WHERE MANUFACTURER FOR THE SPECIFIC CONDITIONS AND SUBSTRATES. <br /> ALTERATION OR RECONSTRUCTION WORK IS PROPOSED, IT SHALL BE 8.- COPINGS, COUNTERFLASHING, AND OTHER METAL WORK : FASTEN <br /> FLASHING TO PREVENT METAL FROM PULLING FREE OR BUCKLING. SEAL TO 2. PROVIDE BACKING MATERIAL BY DOW"ETHAFOAM"OR APPROVED EQUAL. APPLY SEALANT <br /> UNDERSTOOD THAT THE INTENT OF THESE CONSTRUCTION DOCUMENTS TI­l ERMOPLASTIC-POLYOEEI N ROOFING (TPO) OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL JOINTS AND <br /> IS TO RECONSTRUCT THE EXISTING IN ACCORDANCE WITH THE APPLICABLE PREVENT MOISTURE FROM ENTERING THE ROOFING SYSTEM OR VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT BE ACCEPTED. <br /> CODES AND ORDINANCES. SHOULD ANY CONDITION BE UNCOVERED OR BUILDING. 3. ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH MAN- <br /> DEVELOP DURING THE EXECUTION OF THESE DOCUMENTS, WHICH IS NOT I .- TPO ROOFING MEMBRANE SYSTEM : BASIS- OF - DESIGN CARLISE UFACTURER'S WRITTEN INSTRUCTIONS PRIOR TO INSTALLATION. <br /> DEFINED HEREIN, THE CONTRACTOR SHALL CEASE WORK AND NOTIFY SYNTEC INC. : SURE-WELD 80 EXTRA. ROOFING MEMBRANE TO BE 9.- CLEANING : CLEAN AS RECOMMENDED BY MANUFACTURER. <br /> ULTRAVIOLET RESISTANT THERMOPLASTIC POLYLEFIN MEMBRANE 4. KITCHEN EQUIPMENT CONTRACTOR SHALL PROVIDE AND CAULK AROUND ALL EQUIPMENT TO <br /> THE ARCHITECT AT ONCE. CREATE A CLEAN,TIGHT AND WATER PROOF SEAL. <br /> REINFORCED WITH POLYESTER FABRIC. 10.- REGULATORY REQUIREMENTS : CONFORM TO THE 2010 CBC, <br /> CHAPTER 15 FOR ROOF ASSEMBLY FIRE HAZARD REQUIREMENTS. ROOF <br /> a.- THICKNESS ( ASTM D75 1 ) 80 MILS ASSEMBLY FIRE HAZARD CLASSIFICATION : UL CLASS A. -WOOD f-PLASTICS <br /> SUBSU REACE INVESTIGATION NOMINAL I. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE CONTENT NOT <br /> b.- TOLERANCE ON NOMINAL THICKNESS +/- 10 1 1 .- CERTIFICATION : ROOFING SYSTEM AND COMPONENTS SHALL MEET MORE THAN 19%. O <br /> PERCENT OR EXCEEDED FACTORY MUTUAL SYSTEMS APPROVAL AND UL 2. PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES IN QUANTITIES REQUIRED BY LOCAL <br /> I .- A GEOMETRICAL ENGINEER/TESTING LABORATORY WILL BE RETAINED c.- MINIMUM BREAKING STRENGTH (ASTM D75 1 ) 425 LBF/IN. CLASSIFICATION REQUIREMENTS AS PER UL CLASS A. CODE OR APPROVED BY ARCHITECT. r, / <br /> AND PAID BY THE OWNER TO PROVIDE SOILS INVESTIGATION, OBSERVE d.- ELONGATION AT BREAK OF FABRIC (ASTM D75 1 ) 25 PERCENT 3. USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE"S"TRIM HEAD SCREWS FOR LL <br /> ATTACHMENT OR WOOD TRIM TO METAL STUDS, RUNNERS, OR FURRING. <br /> PERFORMANCE OF THE WORK IN CONNECTION WITH EXCAVATING, e.- TEARING STRENGTH (ASTM D5884 130 LBF 12.- WARRANTY : MEMBRANE ROOFING SYSTEM INCLUDING LABOR ANDU-' O <br /> 4. RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5"WIDE AND I" 0_/ <br /> TRENCHING, PLACING OF COMPACTED FILL AND BACKFILLING OPERATIONS, f.- DIMENSIONAL STABILITY (ASTM D 1 204) +/- 1 MATERIALS AND LOSS OF WATER-TIGHTNESS CAUSED BY DEFECTIVE NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS. O W N <br /> AND COMPACTION TESTING OF LAYERED FILL. PERCENT MATERIALS OR WORKMANSHIP, WITH NO DOLLAR LIMIT, SHALL BE 5 INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY CONDITION z Ln <br /> g.- WATER ABSORPTION (ASTM D47 1 ) +/- 2 WARRANTED FOR 20 YEARS FROM DATE OF ACCEPTANCE BY THE OWNER. FOR INSTALLATION. v a) <br /> 2.- THE CONTRACTOR SHALL GIVE AT LEAST TWO WORKING DAYS NOTICE PERCENT G. USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR APPLICATION; Z Q <br /> PRIOR BEGINNING SUCH OPERATIONS. INSTALL IN ACCORDANCE WITH MANUFACTURERS M05T CURRENT PRINTED APPLICATION z Lu U <br /> h.- COLOR WHITE INSTRUCTIONS. <br /> �.- THICKNESS OVER SKIM 0.034 INCH. > <br /> �1 OLLOW METAL DOORS AND FRAMES 7. PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION. RE- z <br /> PLACE DAMAGED SURFACES. O z O <br /> DEMOLITION AND CLEARING INSTALL MEMBRANE ROOFING IN ACCORDANCE WITH MANUFACTURER'S AND WOOD DOORS 8. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED U (\ <br /> INSTRUCTIONS. PROTECT ROOFING AND ADJACENT WORK AGAINST SOLVENT AND CLEANING PROCEDURES. > 00 <br /> I .- DOORS AND FRAMES SHALL BE SIZE AND TYPE AS INDICATED ON THE <br /> I .- THE CONTRACTOR SHALL THOROUGHLY INVESTIGATE THE PROJECT DAMAGE TO ROOFING WORK. PROVIDE TEMPORARY WATER CUT-OFFS AT z <br /> DOOR SCHEDULE OF THE DRAWINGS. ALL FIRE RATED DOORS AND 9. FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND. <br /> THE END OF EACH DAY. INSTALLER SHALL BE QUALIFIED BY ROOFING <br /> SITE, DRAWINGS, AND ALL AVAILABLE DOCUMENTS. FRAMES SHALL HAVE METAL LABELS (INCLUDING S LABELS) 10.INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE FOLLOWING V ) <br /> MANUFACTURE. ROOFING MEMBRANE CONNECTION SHALL BE HOT AIR PERMANENTLY FASTENED TO THE JAMB INDICATING THE FIRE RATING AND CONSIDERATIONS AND REQUIREMENTS: <br /> 2.- THE CONTRACTOR SHALL REVIEW THE PROJECT WITH THE OWNER. WELDED ONLY. TESTING AGENCY NAME AND COMPLY WITH NFPA 80. DO NOT APPLY a. INSTALL ALL MATERIAL WITH TIGHT JOINTS. W <br /> DISCUSS AND VERIFY THE WORK PRIOR TO START OF DEMOLITION WORK. PRIMER OR PAINT OVER THE FIRE RATING LABELS. CLOSERS, GASKETS, b. MITER CASINGS AND MOLDINGS. <br /> 2.- GYPSUM COVER BOARD: G-P GYPSUM CORP. : DENSDECK ROOF c. ALL RUNNING TRIM ONE(1) PIECE UP TO 10'-0". MATCH GRAIN AND COLOR PIECE- <br /> BOARD. GLASS MAT-FACED NONCOMBUSTIBLE, MOISTURE-RESISTANT ETC. SHALL BE PROVIDED ON RATED DOOR ASSEMBLIES TO MAINTAIN TO PIECE. <br /> 3.- LEGALLY DISPOSE OF ALL MATERIAL AND EQUIPMENT REQUIRED TO BE TREATED GYPSUM CORE PANEL , I / 4 INCH THICK, SQUARE EDGES, ASTM ASSEMBLY RATINGS REQUIRED. d. USREws�o NOT SHOW WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR WHERE <br /> REMOVED. C 1 177, AT MECHANICALLY FASTENED SNGLE-PLY ROOFING MEMBRANE e. SET FASTENERS FOR PUTTYING. <br /> 2.- HOLLOW METAL FRAMES : PROVIDE FULLY-WELDED FRAMES AT <br /> 4.- OBTAIN AND PAY FOR ALL PERMITS. SYSTEM. PLACE COVER BOARD OVER CLEAN INSULATION, FASTEN WITH LOCATIONS AS INDICATED ON DRAWINGS. FRAMES SHALL BE FABRICATED f. WHERE SCREW ATTACHMENT IS REQUIRED, SPACE SCREWS AT EQUAL INTERVALS; SINK <br /> DISK-TYPE FASTENERS AS RECOMMENDED BY MANUFACTURER, AND FROM I G GAUGE STEEL WITH INTEGRAL STOP AND TRIM. HEAD AND JAMB AND PUTTY IN FINISHED WOOD SURFACES. <br /> STAGGER ALL JOINTS A MINIMUM OF G INCHES FROM UNDERLYING g. ALL MEMBERS AND LINES SHALL BE LEVEL AND PLUMB. DATE <br /> 5.- THE CONTRACTOR SHALL PROVIDE BARRICADES, DUST PALLIATION, INSULATION JOINTS. SPLICES SHALL BE FABRICATED WITH MITERED, COPED AND h. SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. 05/22/20 <br /> ETC. LIGHTING, TEMPORARY FENCING, WARNING SIGNS, GUARDS, ETC., AS CONTINUOUSLY WELDED. OUTSIDE FACE TO PRESENT A SMOOTH ,i. FINISH EXPOSED SURFACES SMOOTHFREE FROM TOOL AND MACHINE MARKS. <br /> REQUIRED TO PROTECT THE PUBLIC AND WORKERS. 3.- ROOF INSULATION : ATLAS ROOFING CORP.: ACFOAM - II; TAPERED SURFACE FOR PAINTING. J. EASE ALL EXPOSED WOOD EDGES SMOOTH, <br /> MINIMUM RADIUS. SCALE <br /> ACFOAM-II. CLOSED-CELL POLYISOCYANURATE FOAM CORE INTEGRALLY k. INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FIRE <br /> G.- THE CONTRACTOR SHALL REMOVE ALL CONCRETE PAVING, CONCRETE LAMINATED TO HEAVY BLACK ( NON-ASPHALTIC), FIBER-REINFORCED FELT 3.- HOLLOW METAL DOORS : PROVIDE FULLY-WELDED DOORS WITH NO PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS. <br /> CURBS, A.C. PAVING, CONCRETE LIGHT, STANDARD BASES, EXISTING FACERS WITH SQUARE EDGES. COMPLY WITH ASTM C 1289, TYPE 11, CLASS VISIBLE SEAMS OR JOINTS ON FACES OR VERTICAL EDGES OF 1 1.ENSURE THAT ANY AND ALL WOOD AND PLASTICS USED COMPLY WITH ALL MUNICIPALITIES DRAWN <br /> UTILITY LINES, ETC., AS REQUIRED FOR A CLEAN SITE. 1 , ICC ES LISTED AND UL LISTED. CRICKETS SHALL BE FABRICATED USING THICKNESS AS SHOWN ON DRAWINGS. EXTERIOR DOORS TO BE I G REQUIREMENTS FOR FLAMMABILITY AND SMOKE DEVELOPED RATINGS. M.BARRETO <br /> TAPERED INSULATION. GAUGE FACE SHEETS. STIFFENERS TO BE MINIMUM 22 GAUGE. 12.REVIEW THE TENANT CRITERIA IN REGARDS TO USING WOODS AND PLASTICS AND INSTALL NO SUCH <br /> 7.- CLEAR CONSTRUCTION SITE OF VEGETATION, SHRUBS, TREES, ETC., AS MATERIALS WHEN DEEMED UNACCEPTABLE BY THE LANDLORD. IF THESE PLAN AND SPECIFICATIONS JOB <br /> 4.- WOOD DOORS : ALL WOOD DOORS SHALL BE 1 3 /4 INCHES THICK , CALL FOR ANY SUCH MATERIALS TO BE INSTALLED IN A 51TUATION NOT APPROVED BY <br /> REQUIRED. LEGALLY DISPOSE OF ALL EXCESS AND UNSUITABLE a.- COMPRESSIVE STRAIGHT ( ASTM D 162 I ) 20 PSI MINIMUM <br /> MATERIALS. b.- PRODUCT DENSITY ( ASTM D I G22) 2.0 LBS/CF MINIMUM SOLID CORE, WHITE OAK VENEER FOR STAIN AND BIRCH VENEER FOR THE LANDLORD, CONTACT THE ARCHITECT IMMEDIATELY. <br /> c.- WATER ABSORPTION ( ASTM C209) LESS THAITo BY VOLUME PAINT. SHEET <br /> d.- SURFACE BURNING CHARACTERISTICS FLAME SPREAD: 25 TO 50 <br /> (ASTM E84) SMOKE DEVELOPMEN-T050 TO A- 3 ,01 <br />