My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 3:43:35 PM
Creation date
9/1/2020 3:24:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GFTTCER41(AN INC. GR Job # 1820 - 2542 <br /> D. Results of Testing/Servicing SWRCB , Januar) 2(1(16 <br /> Software Version Insia'fed 3 3 3 . 0 5 <br /> Complete the following checklist: <br /> p es o Is the audible alarm operational? <br /> Yes [3 No' Is the visual alarm operational? <br /> 0 Yes No' Were all sensors visually inspected functionally tested, and confirmed operational? <br /> © Yes [3 No' Were all sensors installed at lowest point of secondary containment and positioned so that other oqutpment will not interfere with their <br /> roper operation? <br /> [), Yes El No' If alarms are relayed to a remote monitoring station, is all communication equipment (e g modem) operational? <br /> 13 NIA <br /> d Yes 13 No' For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> N/A detects a leak, fa Is to operate, oris electrically disconnected? If yes: which sensors initate positive shutdown? (Check all that apply) <br /> El Sumpffrench Sensor; 0 Dispenser Containment Sensor DA you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? [ Yes (3 No, <br /> El Yes 13 No* For lank systems that utilize the monitoring system as the primary tank overfill warning device (i.e . no mechanical overfill prevention <br /> (3 N/A valve is Installed). Is the overfill warning alarm visible and audible at the lank fill point(s) and operating pmpedy7 If so, at what percent <br /> of lank capacity does the alarm trigger? 90 % <br /> Ej Yes Q No Was any monitoring equ pmenl replaced? it yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E , below. <br /> Yes (a No Was liquid found Inside any secondary containment systems designed as dry systems? (Check all that apply) 13product; [] Water If <br /> yes, describe causes in Section E, below. <br /> 0 Yes No' Was monitoring system set-up reviewed to insure proper settings? Attach setup reports, if applicable . <br /> Yes ❑ No' I Is all monitoring equipment operational per manufacture's specifications? <br /> • in Section E below, describe how and when these deficiencies were or will be corrected, <br /> E. Comments : <br /> Tank 87 Aux STP UR 794380 - 208 sensor was bad - replaced with like for <br /> like , retested and passed . <br /> Monitoring System Certification Page 2 of 4 1$101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.