My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1700
>
2300 - Underground Storage Tank Program
>
PR0231454
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 12:18:35 PM
Creation date
9/3/2020 12:12:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231454
PE
2361
FACILITY_ID
FA0003796
FACILITY_NAME
Manteca Valero
STREET_NUMBER
1700
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22802002
CURRENT_STATUS
01
SITE_LOCATION
1700 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jan . 23 . 2019 7548AM Donlee Pump Co No . 1366 P . 6 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page s oto <br /> XII . LIFE LEAK DETECTOR TESTING <br /> ❑ Check this box if line leak detectors (LLD) are NOT installed. (Do not complete this section.) r( N NA <br /> This section must be completed if LLDs are fnstalled. <br /> Was a leak simulated to verify LLD performance? ❑ ❑ ❑ <br /> Check at/ that apply.) Simulated teak rate verified: ❑ 3 GP H ❑ 0. 1 GPH [10,2 GPH <br /> Was the testing apparatus properly calibrated? ❑ ❑ ❑ <br /> For emargency generator lank systems , does the LLD create an audible and visual alarm when a leak Is detected? ❑ ❑ ❑ <br /> For mechanioal LLDs, does the LLD restrict the flow through the pipe when a leak is detected? ❑ ❑ ❑ <br /> For electronic LLDs , does the turbine automatically shut off when a leak Is detected? ❑ ❑ a <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Ij ❑ 0 <br /> For electronic LLDs, does the turbine automalloally shut oft if any portion of the monitoring system malfunctions or fails a lest? ❑ ❑ ❑ <br /> For electronic LLDs , have all aco6asible wiring connections been visually inspected fol kinks and breaks? ❑ ❑ ❑ <br /> Were pill items on the equipment manufacturer's maintenance checklist completed? ❑ ❑ ❑ <br /> Were all LLDS confirmed operational within regulatory requirements? ❑ ❑ El <br /> For an answer of «N" above, describe in section V11 how and when these issues were or will be corrected. <br /> X111 , COMMENTS <br /> raft <br /> VL{govt : cc>v, <br /> NMEt1l� <br /> AI <br /> XIVw VACUUM l PRESSURE/ HYDROSTATIC MONITORING EQUIN00071 <br /> Check lits box if VPH monitoring is NOT used . (Do not complete this seotion.)44 <br /> s <br /> This section must be completed if VPH mo►tlforing is used to perform leak detection monitoring. <br /> System Type (Mark oil that apply.) ❑ Vacuum ❑ Pressure ❑ Hydrostatic <br /> Sensor Functionality Interstitial Communication <br /> Sensor ID Components) Monitored by this Sensor Test Test <br /> 0 Pass ❑ Fail ❑ Pass ❑ Fall <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass 0 Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fall ❑ Pass ❑ Fall <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fall i3 Pass d Fail <br /> ❑ Pass ❑ Fall ❑ Pass ❑ Fall <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fall ❑ Pass ❑ Fail <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fall <br /> ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> ❑ Simulated leak at far ends of the interstitial space. Visual inspection <br /> How was interstitial communication verified? ❑ other (Descrlbo the method in section XV below.) ❑ Gauge <br /> Was the vacuum or pressure restored to operating levels in all Interstitial spaces? ❑ Yes ❑ No (Desoribo the reason in section XV below.) <br /> Forany answer of "FAIL" aboVe, describe in section XV how and when these Issues were or will be Corrected <br /> XV. COMMENTS <br /> !MLWAP Sim nate. .n ' t ' <br /> tZnnw !! rzallmwrwrhrrtrY = WA NeNMNA = Nntandlcabte. VPH =V$cuumtPwurdHvdrostaV0. ID = klenHtication <br />
The URL can be used to link to this page
Your browser does not support the video tag.