Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> —COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 816 E FRONTAGE RD, RIPON January 07, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. On the 12/26/18 submittal it states that the 87 <br /> product and diesel product tank have VMI 2000 as mechanical leak detectors and VMI LD2000 for the 91 product <br /> tank. However, the inspector observed that the 91 product and diesel product tanks have Red Jacket FXIV leak <br /> detectors and the 87 product leak detector had VMI LD2000 . The monitoring plan must be uploaded to the <br /> California Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, <br /> and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 1/19/18 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 2/18/18. This information was <br /> received on 3/27/18, over a month late resulting in a non-compliant status for this facility. An operator that receives <br /> an inspection report shall have 30 days to submit a written response that includes a statement documenting <br /> corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br /> documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. No follow up records were <br /> found for the L6-87 STP fuel alarm on 1/27/18, T3-Diese product overfill alarm on 3/1/18, T2-91 product overfill <br /> alarm on 8/30/18,T1-87 product overfill alarm on 8/30/18 and 11/28/18. These records shall be maintained on site <br /> for at least three years. Monitoring records include: (1)date and time of all monitoring or sampling; (2)monitoring <br /> equipment calibration and maintenance records; (3)results of any visual observations; (4)results of sample analysis <br /> performed a lab or in the field; (5)logs of all readings of gauges or other monitoring equipment,ground water <br /> elevations, or other test results; (6)results of inventory readings and reconciliations. Immediately locate and <br /> maintain all maintenance and monitoring records for the last three years on site and submit copies to the EHD. <br /> This is a repeat violation, Class II. <br /> 204 CCR 2712(1)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class ll. <br /> FA0003911 PR0231470 SC001 01/07/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />