My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2021 3:52:48 PM
Creation date
9/3/2020 1:17:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 816 E FRONTAGE RD, RIPON January 07, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document all the alarms from the attached alarm history on the February 2018, <br /> March 2018, September 2018 and December 2018 designated operator monthly inspection report and failed to <br /> check that they were responded to appropriately. The missing alarms include: L6-87 STP fuel alarm on 1/27/18, <br /> T3-Diese product overfill alarm on 3/1/18, T2-91 product overfill alarm on 8/30/18, T1-87 product overfill alarm on <br /> 8/30/18 and 11/28/18. During the monthly inspection, the designated operator shall review the alarm history for the <br /> previous month, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing inspections within 30 days of the previous inspections at this facility are including all of the <br /> required information on the reports. <br /> Furthermore in the 10/25/18 DO report under: <br /> -Section I <br /> The DO failed to write the CERS ID <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII <br /> -Section X <br /> The DO failed to mark YES, NO or N/A under the question"Has the line tightness testing been completed within the <br /> required time frames?"and""Has the tank tightness testing been completed within the required time frames?" <br /> In the 11/19/18 DO report under: <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII <br /> -Section IX <br /> The DO failed to mark Yes, No, or N/A to the question"Are all sensors in under-dispenser containment located to <br /> detect a leak at the earliest opportunity?" <br /> -Section X <br /> The DO failed to mark YES, NO or N/A under the question"Has the line tightness testing been completed within the <br /> required time frames?"and""Has the tank tightness testing been completed within the required time frames?" <br /> This is a repeat violation, Class II. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months(after October 1, 2018). <br /> The April 2018, May 2018, and December 2018 designated operator monthly inspection reports were not found on <br /> site. Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br /> Locate and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit copies to the EHD. <br /> The operations manager was able to get the May 2018 and April 2018 inspection report while the inspector was on <br /> site, however the December 2018 DO report was not found. <br /> This is a repeat violation, Class II. <br /> FA0003911 PR0231470 SCO01 01/07/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.