My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2021 3:52:48 PM
Creation date
9/3/2020 1:17:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N ,J O A Q V I `,N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 816 E FRONTAGE RD, RIPON January 07, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the UDC 1/2 and 91 fill sump. If water could enter into the secondary containment by <br /> precipitation or infiltration, it must be removed and disposed of properly. The service technician removed <br /> approximately 1 gallon of liquid from the UDC 1/2 and 91 fill sump. Ensure that all sumps and annular spaces are <br /> maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> The 87 product VMI line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested it, and it <br /> passed. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The Diesel spill container failed to have a minimum capacity of five gallons. All spill containers shall have a <br /> minimum capacity of five gallons. Immediately contact a properly licensed, trained, and certified contractor to repair <br /> or replace the spill container under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations, title 23 division <br /> 3, chapter 16 section 2635(c)(2)shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair.The site did not performed the testing by October 13th, <br /> 2018 however the service technician on site was able to conduct the overfill prevention equipment inspection today <br /> (1/7/19)while the inspector was on site. Ensure to conduct overfill prevention equipment inspection within the time <br /> frame provided by the regulation and submit test results within 30 days of performing the inspection. Ensure a 48 <br /> hour notification is provided to EHD prior to conducting the inspection. <br /> The service technician on site was able to test the audible and visual alarm, however he was not able to verify that <br /> the ball float installed in all three tanks were in good conditions and in the correct location. Immediately repaired or <br /> replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the failed <br /> component can't be replaced immediately, there is a possibility that the Diesel product, 87 product, and 91 product <br /> UST system may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0003911 PR0231470 SCO01 01/07/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.