COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FOURTH
>
222
>
2200 - Hazardous Waste Program
>
PR0514018
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/14/2020 1:22:39 PM
Creation date
9/3/2020 2:51:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0514018
PE
2220
FACILITY_ID
FA0009747
FACILITY_NAME
GUNTERT & ZIMMERMAN CONST DIV INC
STREET_NUMBER
222
Direction
E
STREET_NAME
FOURTH
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
25936031
CURRENT_STATUS
01
SITE_LOCATION
222 E FOURTH ST
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S0 JOA U 1 Environmental Health Department <br /> u ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GUNTERT&ZIMMERMAN CONST DIV INC 222 E FOURTH ST, RIPON September 02, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel filters. <br /> OBSERVATION: This facility generates drained used metal oil filters. A complete three-year bill of lading record for <br /> used oil filter recycling was not observed during the inspection. Bills of lading were not observed for the following <br /> date range: 9-2-2017 to 9-2-2020. Containers of used metal oil filters out of compliance with the storage rules were <br /> observed on-site. <br /> -One used metal oil filter observed in drain pan located in the hazardous waste storage area. <br /> Note: Operator stated that this facility generates approximately 1-4 used metal oil filters per year. Operator stated <br /> that world oil picks up the used metal oil filters with the waste oil but does not include them on the disposal receipt. <br /> REGULATION GUIDANCE: <br /> (b) "used oil filters"are defined as filters which contain a residue of used oil and which are exempt from regulation <br /> as a hazardous waste under the scrap metal provision found in federal law. <br /> (c)Used oil filters that meet the conditions of subsection (b)of this section and are managed and recycled in <br /> compliance with the following requirements shall not be regulated as hazardous waste. <br /> (1)The filters are drained of free-flowing used oil. For the purposes of this subsection,free-flowing is defined as a <br /> continuous stream of oil exiting the filter when the filter is inverted. Oil exiting drop by drop is not considered to be <br /> free-flowing. However, if the filter is equipped with a device(such as a rubber flap located just inside the filter <br /> opening)which impedes the drainage of used oil from the filter,that device shall be manipulated to allow the oil to <br /> exit the filter freely, or the filter punctured, crushed, opened, drained, or otherwise handled in a manner that will <br /> allow the used oil to exit the filter. <br /> (2)The drained used oil filters are transported for purposes of metal reclamation to any of the following: <br /> (A)A smelter or other scrap metal processor where they are recycled or; <br /> (B)A storage facility or consolidation facility that subsequently transfers the filters to a facility described in paragraph <br /> (A)or(C)of this subsection or; <br /> (C)A municipal solid waste incinerator for energy recovery, if the residual casings are subsequently transferred to a <br /> facility described in paragraph (A)of this subsection,or to a storage or consolidation facility that subsequently <br /> transfers the residual casings to a facility described in paragraph (A)of this subsection. <br /> (3)The drained used oil filters are accumulated, stored, and transferred in a closed, rainproof container that is <br /> capable of containing any used oil that may separate from the filters placed inside. Drums of used oil filters shall be <br /> sealed during transfer so that used oil will not spill out when they are laid upon their sides. Drums shall be secured <br /> as a load to prevent movement or tipping during transfer. Containers shall be labelled as"drained used oil filters" <br /> (not as hazardous waste)and show initial date of accumulation or receipt on each container of filters. <br /> (4)Storage of less than one ton of used oil filters shall be limited to one year. Storage of one ton or more of used oil <br /> filters is limited to 180 days. <br /> (5)Persons generating,transporting, or receiving used oil filters shall use a bill of lading to record the transfer of <br /> used oil filters. Bills of lading must indicate generator,transporter, and receiving company names, addresses, <br /> telephone numbers,the quantity and size of used oil filter containers transferred, and the date of transfer.A copy of <br /> each bill of lading must be kept on the premises of the generator,transporter, and receiving facility where the used <br /> oil filters were handled. Copies of bills of lading shall be kept for a period of three years. <br /> CORRECTIVE ACTION: Immediately drain all metal oil filters of free-flowing oil, store them in closed, rainproof <br /> containers, label the container with the words"drained used oil filters," mark the container with an accumulation start <br /> date and obtain all missing bill of lading recycling records that can be found. Dispose of all used oil filters stored <br /> on-site greater than one year. Used oil filters not stored, handled and disposed of according to this section are <br /> regulated as hazardous waste. Provide a corrective action statement, bill of lading recycling records and <br /> FA0009747 PR0514018 SCO01 09/02/2020 <br /> EHD 22-01 Rev.8/11/2020 Page 6 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.