My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2020 5:20:16 PM
Creation date
9/3/2020 5:08:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� I � O � �� I I I e ' ���.���,��� Environmental Health Department <br /> Iv U f� h_ 1197-B ] <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Pershing Holdings, Inc. DBA Esclon Arco 1329 Escalon Ave, Escalon February 19, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> The designated operator failed to document one or more of the following: <br /> On the 10/29/18, 11/28/18, 12/28/18, and 1/27/19 designated operator(DO) inspection report under <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section V <br /> The owner/operator failed to provide explanation of follow-up actions that will be taken for the statement provided by <br /> the DO in section III. <br /> -Section X <br /> The DO failed to mar YES, NO, N/A and failed to provide a date where necessary under the questions"Has the <br /> monitoring system certification been completed within the past 12 months?", "Has the spill container testing been <br /> completed within the past 12 months?", "Has the tank tightness testing been completed within required timeframes?" <br /> and "Has the line tightness testing been completed within the required timeframes?" <br /> During the designated operator inspection, the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a minor violation. <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Based on the alarm history and the Designated Operator reports from 10/29/18, 11/28/18, 12/28/18 and 1/27/19 <br /> Under-dispenser containment 11/12 has been loosing brine and the facility has been adding brine to address the low <br /> liquid alarm. The sensors monitoring the liquid level in the interstitial space shall be maintained so that a breach in the <br /> primary or secondary containment is detected before the hazardous substance is released into the environment. <br /> Correct immediately by having a properly licensed, trained, and certified contractor replace the failed component <br /> with a functional component(LG 113-x listed, if applicable) and obtain a permit within one business day from the <br /> EHD. If the failed component can't be replaced immediately, there is a possibility that the 87 product, and 91 <br /> product UST system may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> Based on the alarm history and the Designated Operator reports from 10/29/18, 11/28/18, 12/28/18 and 1/27/19 <br /> Under-dispenser containment 11/12 has been loosing brine indicating a leak in the secondary containment. <br /> Secondary containment shall be impervious to the liquid and vapor of the substance contained and constructed to <br /> prevent structural weakening as a result of contact with any hazardous substances released from the primary <br /> containment. Immediately contact a properly licensed, trained, and certified contractor to make repairs to the UST <br /> system under permit and inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> FA0000293 PR0231487 SCO01 02/19/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.