Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 5:31:32 PM
Creation date
9/8/2020 11:58:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
185
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W <br /> OWP <br /> IMPORTANT:To help prevent spillage from an underground storage tank, make sure the delivery <br /> equipment is well-maintained,that there is a proper connection, and that the fill adaptor is tight. <br /> Delivery personnel should inspect delivery elbows and hoses for damage and missing parts. <br /> A CAUTION: Use only original FFS parts. Substituting non-FFS parts could cause the device to <br /> fail, which could create a hazardous condition and/or harm the environment. <br /> A WARNING: Follow all codes that govern how you install and service this product and the <br /> entire system.Always lock out and tag electrical circuit breakers while installing or servicing <br /> this equipment and related equipment.A potentially lethal electrical shock hazard and the <br /> possibility of an explosion or fire from a spark can result if the electrical circuit breakers are <br /> accidentally turned on while you are installing or servicing this product. Refer to this manual (and <br /> documentation for related equipment)for complete installation and safety information. <br /> A WARNING: Before you enter a containment sump, check for the presence of hydrocarbon <br /> vapors. Inhaling these vapors can make you dizzy or unconscious, and if ignited, they can explode <br /> and cause serious injury or death. Containment sumps are designed to trap hazardous liquid <br /> spills and prevent environmental contamination, so they can accumulate dangerous amounts <br /> of hydrocarbon vapors. Check the atmosphere in the sump regularly while you are working in <br /> it. If vapors reach unsafe levels, exit the sump and ventilate it with fresh air before you resume <br /> working. Always have another person standing by for assistance. <br /> A WARNING: Follow all federal, state, and local laws governing the installation of this product <br /> and its associated systems. When no other regulations apply,follow NFPA codes 30, 30A, and 70 <br /> from the National Fire Protection Association. Failure to follow these codes could result in severe <br /> injury, death, serious property damage, and/or environmental contamination. <br /> A WARNING: Always secure the work area from moving vehicles.The equipment in this manual <br /> is usually mounted underground, so reduced visibility puts service personnel working on it in <br /> danger from moving vehicles that enter the work area.To help prevent this safety hazard, secure <br /> the area by using a service truck (or some other vehicle) to block access to the work area. <br /> A WARNING: This product contain a strong magnet. Make sure it does not come into the vicinity <br /> of a person with a pacemaker or similar medical aid.The magnetic field associated with this <br /> product can adversely affect such devices. <br /> A WARNING: If you are working with drop tubes that have been exposed to fuel or other <br /> flammable substances, allow these substances and any vapors to dissipate in a well-ventilated <br /> area for an hour before you perform any procedures. <br /> A WARNING: Discharge to ground before putting into service and ensure valve is properly <br /> grounded while in service. <br /> A WARNING: When inserting the drop tube/valve assembly into the tank riser pipe, use caution <br /> not to forcefully impact the tank riser pipe. When raising/lowering the drop tube/valve assembly <br /> while inside the tank riser pipe, do so in a slow, controlled manner. <br /> A WARNING: It is the responsibility of the end user of this product to evaluate each installation <br /> location for the following potential ignition sources: lightning, high frequency radio waves, <br /> electromagnetic radio waves, ionizing radiation, and ultrasonic sound waves. If any of these <br /> potential ignition sources are identified, protective systems/measures shall be implemented. <br /> 2 PNO — <br />
The URL can be used to link to this page
Your browser does not support the video tag.