My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 10:47:39 AM
Creation date
9/8/2020 2:12:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
76 FUEL ISLAND & CARWASH
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
03
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> ,. .G Linda Turkatte,REHS <br /> Q. y� 1868 E Hazelton Avenue <br /> Stockton, California 95205 ASSISTANT DIRECTOR <br /> Kasey Foley,REHS <br /> q Ta;P Website: www.sjcehd.com PROGRAM COORDINATORS <br /> "F 0V= Phone: (209) 468-3420 Robert McClellon,REHS <br /> Fax: (209)464-0138 JeffC'arruesco,REHS,RDI <br /> Michael Kith,REHS <br /> Muniappa Naidu,REHS <br /> Willy Ng,RFHS <br /> February 1, 2019 <br /> MEL HIGGINBOTHAM <br /> PM DESIGH GROUP INC <br /> 6930 DESTINY DR. STE. 100 <br /> ROCKLIN, CA 95677 <br /> RE: C-STORE W/76 FUEL ISLAND, 141 E Harney Ln., Lodi, CA 95240 SR0079417 <br /> The most recent revised permit application to install an underground storage tank (UST) system <br /> at the above address was received and reviewed by the San Joaquin County Environmental <br /> Health Department (EHD). In order for this application review to continue please address each <br /> comment below and provide additional information (three copies each) as needed; all revisions <br /> should be included in clouds or clearly identified using other methods, only revised pertinent <br /> pages should be included with your submittal: <br /> 1) Permit application page 3 of 8 is missing applicant's signatures, workers compensation <br /> number, contractor's phone number, and fire district information. Page 3 of 8 of the <br /> permit application lists monitoring panel as 790091-001, TLS-350 was identified on your <br /> drawings. Defender series overfill valve cut sheet was provided, but OPW flapper valve <br /> is listed on your permit application (page 7 of 8), correct as appropriate and resubmit. <br /> 2) The submitted ELD work plan is not acceptable for the proposed tanks, please provide a <br /> revised ELD work plan. Please refer to the State Water Resources Control Board letter <br /> dated September 14, 2018 for additional information on ELD testing requirements <br /> (attached). <br /> 3) Provide all tank and sump cut sheets, for example Xerxes installation instructions were <br /> provided in your recent submittal in lieu of cut sheets. <br /> 4) OPW flapper valve calculation sheet was provided, it appears that maybe a Defender <br /> Series flapper valve is being proposed, please clarify, submit the appropriate calculation <br /> worksheet <br /> 5) Confirm that the proposed Phil-Tite sump covers (STP and fill sumps) are VPH <br /> compliant. <br /> 6) Please point out your safety factors on the provided buoyancy calculations; one safety <br /> factor for each tank. Also page 2 of 10 of this calculation indicates that "the deadman <br /> slab shall be 36' long x3' deep x12' wide to achieve adequate weight to resist buoyancy <br /> force", please clarify if a slab of this thickness is being proposed, none was noted on the <br /> submitted plans. <br /> 7) Drawing G.0.1 (as well as several other proposed drawings) show that canopy footing will <br /> be touching or will be extremely close to the proposed fuel piping, please revise and <br /> resubmit to reflect appropriate set back distances. <br /> Page I of 2 141 E Harney Ln., Lodi CA SR0079417 <br />
The URL can be used to link to this page
Your browser does not support the video tag.