Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s' ov.org/eh <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A G SPANOS AVIATION DEPT* 4800 S AIRPORT WAY, STOCKTON February 14, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> The Tank-2 sump line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br /> detecting a 3-gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, and certified contractor <br /> repair or replace the failed leak detector(LG 113-x listed, if applicable) and obtain a permit within one business day <br /> from the EHD. If the failed leak detector can't be replaced immediately, there is a possibility that the UST system <br /> may be red tagged to prevent fuel inputs. <br /> This is a minor violation. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Overfill prevention testing conducted on 10/4/18 included percent capacity based on the linear location instead of <br /> the tank volume. A check of the numbers for T-3 (overfill level from test results: 86", tank chart max volume: 11,627 <br /> gallons, tank chart volume at 86": 11,326 gallons) indicate the flapper is set at 97.4%. The results also state the <br /> vent piping is secondarily contained; the tank forms state the vent piping is single-walled. This testing was required <br /> to be conducted by October 13, 2018 and include the location of the flapper at a percent of volume capacity of the <br /> tanks. Immediately update these test results and ensure that all flappers are located at the proper tank volume. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 16, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes, Permit Guidance <br /> document <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: <br /> Date: February 14, 2019 Inspector: Inspector Phone: <br /> ✓,'�/,� a=> Printed Name and Title: STACY RIVERA, Senior REHS (209)468-3440 <br /> Thomas Tilley, Aviation Support Supervisor <br /> FA0003809 PR0231509 SCO01 02/14/2019 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />