Laserfiche WebLink
ground surface as often as required in a fashion which will not allow for runoff into surface water. <br /> Alternatively, a peristaltic pump using dedicated polypropylene tubing at each well may be used for <br /> purging and sampling. After purging,groundwater samples will be collected from the sampling device <br /> (bailer or peristaltic pump) directly into appropriate sample containers. All samples will be stored on <br /> ice and transported,under proper chain of custody,to the laboratory for analysis. It is anticipated <br /> that samples will be analyzed at Presicion Laboratory Inc.,Stockton, California. A log of gauging, <br /> purging and sampling activities will be completed for each well by the sampler,using a field report <br /> sheet similar to the one included in Appendix B. <br /> Quality assurance and quality control (QA/QC) samples (i.e., field blanks, trip blanks,laboratory <br /> blanks) are not anticipated for use during this project,but may be collected if the groundwater <br /> professional overseeing sampling activities determines a need for QA/QC sample analysis. <br /> Table 1:Anal cal Re uirements for Groundwater Samples <br /> Test Parameter DLR Unit Method Frequency <br /> H unit EPA 150.1 Quarterly <br /> Total Dissolved Solids 1.0 mg/Lmg/L EPA 160.1 Quarterly <br /> Nitrate as N 0.20 mg/Lmg/L EPA 300.0 Quarterly <br /> Total Kjeldahl Nitrogen 0.20 mg/Lmg/L EPA 351.2 Quarterly <br /> Total Alkalin 1.0 mg/Lmg/L EPA 310.1 Annuall <br /> Carbonate Alkalin 1.0 mg/ EPA 310.1 Annually <br /> Bicarbonate Alkalin 1.0 mg/ EPA 310.1 Annually <br /> Hydroxide Alkalin 1.0 mg/Lmg/L EPA 310.1 Annually <br /> Calcium 1.0. mg/Lmg/L EPA 200.7 Annually <br /> Chloride 1.0 mg/Lmg/L EPA 300.0 Annually <br /> Hardness as CaCO3 6.6 mg/L mg/LCalc. Annually <br /> Potassium 1.0 mg/Lmg/L EPA 200.7 Annually <br /> Magnesium 1.0 mg/ EPA 200.7 Annually <br /> Sodium 1.0. mg/Lmg/L EPA 200.7 Annually <br /> Sulfate as SO4 1.0 mg/Lmg/L EPA 300.0 Annually <br /> Boron 10ug/]_ EPA 200.7 Annually <br /> Iron 50 ug/4ug/4 EPA 200.7 Annually <br /> Notes: <br /> (1) Annual sample analysis will be conducted 2 weeks after well installation and during the last <br /> quarter of each year. <br /> (2) Sample containers include one plastic quart bottle per well. <br /> 6.0 Evaluation of Analytical Results <br /> Quarterly monitoring reports shall be submitted within 30 days after each groundwater sampling <br /> event. Those reports shall include all field sampling logs and laboratory analytical report sheets for <br /> the most recent monitoring event, a tabular times series presentation of cumulative monitoring data <br /> (well gauging and analytical results) for each constituent at each monitoring well, a narrative <br /> discussion of actual procedures used during the sampling event,maps showing the analytical results at <br /> 8 <br />