Laserfiche WebLink
Environmental Health Department <br /> SAN JOAQUIN Zgy,L�1w <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY76 2420 W GRANT LINE RD, Tracy May 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plan did not include the <br /> manufacture or model of the UDC leak sensor. The monitoring plan must be uploaded to the California Environmental <br /> Reporting System (CERS).The site manager was able to log into CERS while the inspector was there to close this <br /> violation. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 110 CCR 2637(e), 2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> Secondary containment testing was performed on 5/17/18 and a test report was submitted on 7/9/18, 23 days late. <br /> A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure <br /> testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, and leak detector testing was performed on 5/22/18 and a test report was <br /> submitted on 7/9/18, 18 days late. A copy of the test report must be submitted within 30 days of the tests. Take all <br /> necessary precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 5/22/18 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 6/21/18 . This information was <br /> received on 8/20/18, 30 days late resulting in a non-compliant status for this facility. An operator that receives an <br /> inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br /> actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br /> corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 123 CCR 2637.1(d), 2637.1(e) Failure to submit the "Spill Container Testing Report Form"within 30 days after the test. <br /> Spill container testing was performed on 5/22/18 and a test report was submitted on 7/9/18, 18 days late. A copy of <br /> the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure testing and <br /> submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> FA0003963 PR0231580 SCO01 05/22/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />