My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
2300 - Underground Storage Tank Program
>
PR0542283
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 8:47:43 AM
Creation date
9/14/2020 10:51:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0542283
PE
2351
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AMPM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> lO{.DUIN. C`. <br /> a SQN !. JOAQUI0 <br /> � ,. Environmental Health Department <br /> ;'� COUNTY <br /> l ` = Linda Turkatte, RENS , Director <br /> Greatness c lows here . <br /> ) Kasey Foley , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> YFILE Robert McClellon, REHS <br /> Jeff Carruesco, REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng, REHS <br /> Munlappa Naldu , REHS <br /> February 23 , 2018 <br /> Chris Brown <br /> PM Design Group , Inc. <br /> 2455 Bennett Valley Road , Ste . A- 102 Sent by Email and Certified Mail <br /> Santa Rosa CA, 95404 <br /> RE : 2010 Crestwood Avenue, Manteca CA 95336 . SR0078213 <br /> The permit application to install an underground storage tank ( UST) system at the above noted <br /> address was received by the San Joaquin County Environmental Health Department (EHD) October 2 , <br /> 2017 . In order for this permit application review to continue , a detailed addendum and revised sheets <br /> for plans (as applicable) must be provided for the following deficiencies . Note : if deficiencies are found <br /> on future submittals , then a new deficiency letter will be issued . <br /> 1 . The permit application is incomplete . The application for the underground storage tank installation <br /> packet needs to be completed . On the tank forms submitted , Xerxes tanks are proposed . <br /> However, the site plan list containment solutions as the tank purposed . Clarify which tanks are <br /> going to be used for the install and submit the correct tank forms . The fire department permit <br /> number needs to also be included in the permit application . In addition , an ELD work plan was not <br /> submitted with the permit packet . Submit an ELD work plan for review by EHD . <br /> 2 . The submitted buoyancy calculations need to be signed and stamped by a professional engineer <br /> (per permit conditions) . Submit copies to the EHD that meet this requirement . <br /> 3 . No tank charts and overfill calculations were received with the permit application . Submit the charts <br /> and calculations to the EHD for review as part of the permit application . <br /> 4 . No certifications for the tank installer and service technician were received . Submit information <br /> detailing who will be performing all of the work and testing along with their certifications . <br /> 5 . A map showing the location of the wells , sceptic a systems , etc. needs to be included ( per page 4 of <br /> the EHD permit application ) , revise and resubmit . <br /> 6 . The locations of the vacuum zones need to be clearly drawn on the site plans and labeled . In <br /> addition , please identify the vacuum zone sensor locations on the site map . <br /> 7 . Clarify how vacuum continuity will be tested with every end termination of piping . <br /> 8 . Clarify how brine continuity will be tested in the fill sumps , submersible turbine pump (STP) sumps , <br /> and the under dispenser containment (UDC) units . <br /> 9 . Clarify which overfill prevention method (s) are going to be used on the permit application and the <br /> drawings . <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br /> 9171 9690 0935 0159 9050 55 <br />
The URL can be used to link to this page
Your browser does not support the video tag.