My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 12:33:05 PM
Creation date
9/15/2020 10:39:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN" J D�l+ �� I 1411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Marks Fuel& Food Inc. T880 E VICTOR RD LODI October 09 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> The following maintenance and monitoring records for the last three years were not found on site. <br /> -2018 Monitoring System Certification <br /> -2019 Overfill Prevention Test Results <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain all missing maintenance and monitoring records for the last three <br /> years on site and submit copies to the EHD. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 202 CCR 2715(c)(3), 2715(c)(4) Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> Facility Employee Training Certificate for Moises Munoz was not found onsite .The designated operator shall train <br /> facility employees for which he or she is responsible in the proper operation and maintenance of the UST system <br /> once every 12 months.The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the training records to the EHD. <br /> This is a Class II violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a Class II violation. <br /> FA0003862 PR0231746 SCO01 10/09/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 7 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.