SANJ O A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date. <br /> ALPHA FAST GAS * 2358 E WATERLOO RD , STOCKTON June 27 , 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ■ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS Il , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 101 HSC 25284 ; CCR 2711 (d ) Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit <br /> fees . <br /> A permit to operate the UST system has not been issued . No person may own or operate an UST unless a permit for <br /> its operation has been issued by the local agency to the owner or operator of the UST system . Immediately obtain a <br /> permit to operate a UST system from the EHD . An " Operating without a Permit' penalty applies . <br /> This is a Class I violation. <br /> 102 HSC 25284 (a) (3) (A)/(B ) No written agreement between tank owner and tank operator to monitor the tank system . <br /> The annual operating permit is not issued to the current operator and there is no written agreement between the <br /> person who was issued the permit and the operator to monitor the UST system . If a permit is issued to a person <br /> other than the operator of the tank , that person shall enter into a written agreement with the operator of the tank to <br /> monitor the UST system . Immediately submit a copy of this written agreement to the EHD . Alternatively, log into <br /> CERS , upload the written agreement , and submit for review by the EHD . <br /> This is a minor violation . <br /> 103 HSC 25292 . 21 25299 . 30 Failure to submit and maintain complete and current financial responsibility documents . <br /> Current Financial responsibility documents have not been submitted to the EHD . Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting <br /> System (CERS) at http : //cers . calepa . ca . gov/, and upload the required documents . <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current . <br /> UST Facility Operating Permit Application BOE number is incorrect. The number listed is shown on the CDTFA <br /> website as closed and not valid . Immediately log into CERS , update the required information , and submit for review <br /> by the EHD . <br /> This is a repeat violation , Class II . <br /> 105 CCR 2632 (d ) (1 ) , 2634 (d ) Failed to have an approved UST monitoring plan . <br /> The monitoring plan is not current and/or not approved by the EHD . The monitoring plan for all of the tanks <br /> incorrectly list the name of the person having responsibility. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS) . Immediately log into CERS , make the necessary changes , and submit for <br /> review by the EHD . <br /> This is a minor violation. <br /> FA0006343 PR0231756 SC001 06/27/2019 <br /> EHD 23-01 Rev, 09/28/2018 Page 4 of 8 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />