Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> OIJNIY - <br /> P� �Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: FDae: <br /> ALPHA FAST GAS * 2358 E WATERLOO RD , STOCKTON ne 27 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS 11 , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 106 CCR 2632 (d ) (2) , 2634 (e) Failed to have an approved UST response plan . <br /> The response plan is not current and/or not approved by the EHD . The response plan must be uploaded to the <br /> California Environmental Reporting System (CERS) . Immediately log into CERS , upload the completed form , and <br /> submit for review by the EHD . Ensure a copy is available for inspection at any time . <br /> This is a minor violation. <br /> 110 CCR 2637 (e) , 2637 (f) Failed to submit "Secondary Containment Testing Report Form " within 30 days after the test . <br /> Secondary containment testing was performed on 3/29/2018 . A test report has not been submitted to the EHD or the <br /> California Environmental Reporting System (CERS) . A copy of the test report must be submitted within 30 days of <br /> the test . Immediately provide this report to the EHD . <br /> This is a minor violation. <br /> 111 CCR 26381 26410 ) , 2715 (f) Failed to test monitoring and leak detection equipment every 12 months . <br /> Annual monitoring system certification and leak detector testing were last performed on 04/05/2018 and was due by <br /> 04/2018 . Testing has not been completed and is 3 months past due . These tests are required once every 12 <br /> months . Immediately schedule these tests and provide 48 hours notification to the EHD . Please be aware that a <br /> follow up inspection will be charged at our current hourly rate . <br /> This is a Class II violation. <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance . <br /> Maintenance and monitoring records for the last three years were not found on site . These records shall be <br /> maintained on site for at least three years . Monitoring records include : ( 1 ) date and time of all monitoring or <br /> sampling ; (2 ) monitoring equipment calibration and maintenance records ; (3) results of any visual observations ; (4) <br /> results of sample analysis performed a lab or in the field ; (5) logs of all readings of gauges or other monitoring <br /> equipment , ground water elevations , or other test results ; (6) results of inventory readings and reconciliations . <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies to the EHD . <br /> This is a minor violation . <br /> 118 CCR 2715 (a) ( 1 ) (A) , 2715 (a ) (2) Failure to submit the " Underground Storage Tank Statement of Understanding and <br /> Compliance Form " . <br /> The Underground Storage Tank Statement of Understanding and Compliance Form is not current in CERS . This <br /> form must be uploaded to the California Environmental Reporting System (CERS) . Immediately log into the California <br /> Environmental Reporting System (CERS) at http : //cers . calepa , ca , gov and upload the Underground Storage Tank <br /> Statement of Understanding and Compliance Form for this facility . <br /> This is a minor violation. <br /> FA0006343 PR0231756 SCO01 06/27/2019 <br /> EHD 23-01 Rev, 09/28/2018 Page 5 of 8 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468 -3420 F 209 464-0138 1 www. sjcehd. com <br />