My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:28:48 PM
Creation date
9/15/2020 3:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231995
PE
2361 - UST FACILITY
FACILITY_ID
FA0006438
FACILITY_NAME
United # 5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1403 W COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
pei.org 9 <br />Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities <br />CAUTION: Use only an air-operated vacu- <br />um source or a vacuum pump powered by <br />an explosion-proof motor. Vacuum pumps <br />with electric motors that are not explo- <br />sion-proof may ignite flammable vapors. <br />If a portable air compressor is used, it <br />should be located at least 20 feet away <br />from the venturi-eductor or outside any <br />Class I, Division 1 area. <br />4.2.4 Preparation. The procedures in this sec- <br />tion are general in nature and reflect the suggested <br />vacuum levels and hold times for testing tank <br />secondary containment areas. Consult tank manu- <br />facturer and authority having jurisdiction (AHJ) <br />guidelines before performing these tests, as their <br />requirements may differ. <br />Determine if there is liquid present in the intersti- <br />tial space. If liquid is found, determine if the fluid <br />is water or product, and remove it to the extent <br />practicable. <br />The hydrostatic pressure from a high water table <br />imposes inward pressure on the outer wall of a <br />UST. Applying a vacuum to the interstitial space <br />of the tank creates additional pressure on the outer <br />wall. These combined forces can damage the <br />secondary tank wall when there is a large defined <br />space between the primary and secondary tanks. <br />Consequently, to prevent damage to the tank, it is <br />important to observe the water table and associated <br />recommended vacuum levels when testing. <br />Vent the primary tank to atmosphere during the <br />test. <br />In some installations, the tank interstitial space <br />may be vented to minimize the buildup of conden- <br />sation. In these cases, seal off any vent lines to the <br />tank interstitial space prior to testing. <br />Determine the volume of the tank. This informa- <br />tion is available from facility records or the auto- <br />matic tank gauge (ATG) readout. <br />4.2.5 Steel Tanks. Determine if the interstitial <br />space is a “tight-wrap” design or a “110% contain- <br />ment” design. Tanks with a 110% containment <br />design should use the latest version of Steel Tank <br />Institute’s (STI) R012, Recommended Practice for <br />Interstitial Tightness Testing of Existing Under- <br />ground Double Wall Steel Tanks for testing. <br />For tight-wrap tanks, use the test method in this <br />section. <br />4.2.6 Fiberglass Tanks. Determine if the inter- <br />stitial space is a “tight-wrap” design or a “110% <br />containment” design. Either type of fiberglass tank <br />may use this test or the latest version of Fiberglass <br />Tank & Pipe Institute’s (FTPI) RP 2007, Field Test <br />Protocol for Testing the Annular Space of Installed <br />FIGURE 4-4. The plumber’s plug provides a leak-tight <br />connection to draw a vacuum on the tank interstitial <br />space. <br />FIGURE 4-3. The vacuum gauge and control valve used <br />for tank interstitial testing.F
The URL can be used to link to this page
Your browser does not support the video tag.