Laserfiche WebLink
SAN1UAQUIN AMENDEDEnvironmental Health Department <br /> --COUNTY Ee— �-Gl�C <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FedEx Ground -Tracy 5655 Hood Way, Tracy July 11, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document one or more of the following.. <br /> On the 10/19/18,11/16/18, 12/14/18, 1/11/19, 2/6/19, 3/6/19, 4/4/19, 5/3/19 and 6/28/19, designated operator(DO) <br /> inspection report under <br /> -Section I <br /> The DO fail to provide CERS ID <br /> -Section III <br /> The DO failed to add a description to all the components marked N/A or N from section VII through XI. <br /> -Section V <br /> The owner/operator failed to provide explanation of follow-up actions that will be taken for the statement provided by <br /> the DO in section III. <br /> -Section VII <br /> The DO fail to mark yes or No for the question "Has each follow-up action of section III from the previous inspection <br /> been completed appropriately?" <br /> DO refers to work orders but the work order was not attached to the DO report as <br /> requested under section VIII of the DO report. <br /> -Section IX <br /> The DO failed to mark Y/N/NA under the question "Is the under-dispenser containment free of damage, water, debris, <br /> and hazardous substance?"for DSL M <br /> The DO failed to mark Yes, No or N/A to the question "Are all sensors in under-dispenser containment located to <br /> detect a leak at the earliest opportunity?" <br /> -Section XI <br /> The DO failed to mark Yes or No to the question "Have all individuals performing facility employee duties received the <br /> required facility employee training within the past 12 months?" <br /> Furthermore, the DO failed to check that Overfill alarms on T2- Diesel 2 Middle on 9/12/18, 9/11/18 9/10/18, T3- <br /> Biodiesel Prove out alarm on 10/17/18 and S2- Diesel 2 Middle No Vac alarm on 12/22/18 were responded to <br /> appropriately. <br /> The Designated operator failed to put the correct date on the November Designated operator report. He wrote <br /> 11/19/18, however the alarm history and the signature from the owner/operator state 11/16/19. <br /> During the designated operator inspection, the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br /> history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br /> performing inspections at least once every 30 days at this facility and are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> FA0023065 PR0540345 SCO01 07/11/2019 <br /> EH 23-01 Rev.09/28/2018 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />