My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2020 10:43:39 AM
Creation date
9/16/2020 10:27:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANtIOAQUIN EIDp Environmental Health Department <br /> M <br /> COUNTY— Zt3 �I ISI iq <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FedEx Ground -Tracy 5655 Hood Way, Tracy July 11, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The Diesel 1 tank fill sump failed to have brine communication when tested. The sensors and interstitial liquid <br /> monitoring the interstitial space shall be maintained so that a breach in the primary or secondary containment is <br /> detected before the hazardous substance is released into the environment. Correct immediately by having a properly <br /> licensed, trained, and certified contractor replace the failed component with a functional component(LG 113-x listed, <br /> if applicable) and obtain a permit within one business day from the EHD. If the failed component can't be replaced <br /> immediately, there is a possibility that the diesel UST system may be red tagged to prevent fuel inputs. <br /> This is a repeat violation, Class Il. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> Fuel filter in UDC 3/4 was observed to be weeping, fuel was also observed inside the brine reservoir of the UDC, <br /> indicating a leak in the primary piping. All primary containment for the UST system must be tight. Immediately have <br /> a properly licensed, trained, and certified contractor repair or replace the failed component under permit and <br /> inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> Water was found in the Diesel #2 fill sump. Secondary containment shall be constructed to prevent any water <br /> intrusion into the system by precipitation, infiltration, or surface runoff. Immediately remove this liquid, make a <br /> hazardous waste determination per Title 22 hazardous waste regulations, and manage accordingly. Immediately <br /> contact a properly licensed, trained, and certified contractor to address the water intrusion into the Diesel#2 fill <br /> sump under permit and inspection of the EHD. <br /> This is a repeat violation, Class Il. <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations, title 23 division 3, <br /> chapter 16 section 2635(c)(2) shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair. The site did not performed the testing by October 13th, <br /> 2018. Ensure to conduct overfill prevention equipment inspection within the time frame provided by the regulation and <br /> submit test results within 30 days of performing the inspection. Imminently schedule the overfill prevention equipment <br /> inspection. Ensure a 48 hour notification is provided to EHD prior to conducting the inspection. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> FA0023065 PR0540345 SCO01 07/11/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.