My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2020 3:50:20 PM
Creation date
9/16/2020 4:45:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VEEDERowROOT <br /> CEB 2018 - 02A <br /> Continuing Education Bulletin <br /> Protection 'Testing <br /> J1-c--0 - <br /> This Continuing Education Bulletin provides additional information to Veeder- Root service network and <br /> technicians regarding Overfill Protection Testingthe=l LS-4�OR6tJ� Traci T6S4-Et+�erraet a��d-SMS P- Scamp. <br /> Scope : <br /> This document will provide a Veeder" Root ATG certified technician a proceduMft stfelwAestTmk <br /> Overfill Protection . , <br /> Consoles <br /> TLS-450PLUS TLS4c TLS4i TLS -450 and TLS3XX N 0 V 13 2018 <br /> Requirements . ENVI ONVIENT 'll , r 6L' lyl <br /> TLS-450PLUS TLS4c TLS4i , TLS- 450 : Automatic Event : Device Task programmed to. 10 ger ortpnk _ <br /> Overfill and close a relay feeding voltage to the Overfill Alarm Device " <br /> TLS-3XX : Output Relay programmed to close a relaV on a Tank Overfill alarm feeding voltage to the <br /> overfill Alarm Device <br /> Procedure . <br /> 1 . Inspection <br /> a . Verify the levels in the tank to make sure there is product in the tank and that the tank is <br /> enabled <br /> b . Clear all tank alarms and other alarms which may affect the Overfill test <br /> c . If the site is currently receiving a delivery, wait until the delivery is complete <br /> d . If the tank is performing a SLD Tank test , stop the test <br /> 2 . Preparation <br /> a . Turn Alarm filtering off, this will allow you to clear alarms quicker <br /> b . Program Delivery delay to 1 minute , this will allow the delivery to be completed quicker <br /> L Note the customers original value , so You can restore it after the test <br /> c . Print the Tank Inventory Report <br /> d . Test the relay assigned to the Overfill device to insure the overfill device works <br /> i . If the Overfill device does not sound , repair the device before continuing testing <br /> 3 . Testing <br /> a . Turn off power to the console <br /> b . Disconnect the probe from the field wiring and remove it from the riser <br /> I . If you are testing more than one tank remove all the probes from their risers <br /> c . Lay the probe safely on the around and reattach the field wiring . <br /> d . Position the water float at the bottom of the probe and the product float 25% up from the <br /> bottom of the probe . <br /> e . Power the console back on <br /> f. Simulate a delivery <br /> L Move the float towards the top of the probe at a rate of 1 -2 " per ten second <br /> ii , Continue moving the float to the top of the probe at a rate of 1 -2 " per ten seconds <br /> for the next 50 seconds , the probe is not in delivery mode <br /> C-E-f;_'�� Q_A Veeder- Root Company I Technical Support M4 EST : 8am - 6pm 1 1 - 800-3234799 <br /> technicalsupport@veeder , com I www , veeder . com /support <br />
The URL can be used to link to this page