M
>
MORADA
>
4219
>
2300 - Underground Storage Tank Program
>
PR0524617
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2020 4:11:42 PM
Creation date
9/18/2020 2:46:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0524617
PE
2351
FACILITY_ID
FA0016523
FACILITY_NAME
AISLE 1 #2356
STREET_NUMBER
4219
Direction
E
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429017
CURRENT_STATUS
01
SITE_LOCATION
4219 E MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> -- COUNTY - <br /> Underground <br /> COUNTYUnderground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> AISLE 1 #2356 4219 E MORADA LN , STOCKTON July 09 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 201 CCR 2712 ( b) ( 1 -2 ) Failure to maintain monitoring , maintenance , and follow up action records . <br /> Maintenance and monitoring records for the last three years were not found on site . <br /> -Overfill Prevention Equipment Inspection test result <br /> - 2018 Monitoring System Certification <br /> These records shall be maintained on site for at least three years . Monitoring records include : ( 1 ) date and time of <br /> all monitoring or sampling ; (2 ) monitoring equipment calibration and maintenance records , (3) results of any visual <br /> observations , (4 ) results of sample analysis performed a lab or in the field , (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations , or other test results , (6) results of inventory readings and <br /> reconciliations . Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD . <br /> This is a minor violation . <br /> 204 CCR 2712( 1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection . A copy of these plans shall be <br /> accessible on site at all times . Immediately locate and retain a copy on site. <br /> This is a minor violation . <br /> 205 CCR 2712 (i) , 2634 (e) Failure to submit a current UST Response Plan and have it available onsite . <br /> An approved copy of the response plan was not available for inspection . A copy of this plan shall be accessible on <br /> site at all times . Immediately locate and retain a copy on site . <br /> This is a minor violation . <br /> 209 CCR 2716 (a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days . <br /> The following was observed on the designated operator's monthly inspection reports ( December 2018 - June 2019) : <br /> -The " N/NA" in sections VII through XI were not fully explained on the inspection reports . <br /> - Reports were missing date , name and signature of the UST owner/operator. <br /> During the visual inspection , the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports . <br /> This is a minor violation . <br /> Overall Inspection Comments : <br /> The monitoring system certification was conducted on 7/9/2019 and was not fully witnessed by EHD . Looked <br /> inside all sumps and UDCs . Verified sensor locations and piping communication . Verified spill bucket 5 gallon <br /> capacity . <br /> An inspection checklist was provided to the facility operator on the day of inspection . EHD has written the <br /> complete report which replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> j FA0016523 PRO524617 SCO01 07/09/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www, sjcehd . com <br /> I <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.