Laserfiche WebLink
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AISLE 1 #2356 4219 E MORADA LN, STOCKTON July 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> 1) Financial responsibility documents have not been submitted to the EHD.The Storage Tank Certificate of <br /> Insurance to Demonstrate Financial Responsibility expired of on 6/30/2019. Current financial responsibility <br /> documents are required to be submitted annually. Immediately log into the California Environmental Reporting <br /> System (CERS)at http://cers.calepa.ca.gov/, and upload the required documents. <br /> 2)An approved copy of the financial documents were not available for inspection. A copy of these documents shall <br /> be accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the 87 and 91 tanks are not current in CERS. The Tank forms for the 87 and 91 <br /> tanks incorrectly list the riser as"fiberglass".Any change of information must be updated in CERS within 30 days of <br /> the changes. Immediately log into CERS, update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. The monitoring plans for all tanks incorrectly list <br /> the piping secondary containment as"dry".The 91 monitoring plan lists the UDC panel as a TLS350R;the 87 and <br /> diesel monitoring plans list the UDC panel as a TLS350.The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d), 2641(h),2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The monitoring site plan does not include piping and the <br /> legend does not match the symbols used.A site plan must be submitted identifying the locations where monitoring <br /> will be performed. Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 7/10/2018 <br /> and a test report was submitted on 12/12/2018,4 months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a minor violation. <br /> FA0016523 PR0524617 SCO01 07/09/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />