COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 12:57:14 PM
Creation date
9/21/2020 10:28:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5. SECONDARY PIPE TESTING <br /> Test Method Developed By: El Piping Manufacturer ❑✓ Industry Standard ❑Professional Engineer <br /> ❑Other(Specie) <br /> Test Method Used: ❑✓ Pressure ❑Vacuum ❑Hydrostatic <br /> El Other(Spec) <br /> *Equipment Used: See attached testing procedures Equipment Resolution: PSI <br /> Piping Run#87 Vent Piping Run#91 Vent Piping Run#Diesel Vent Piping Run# <br /> al: Fiberglass Fiberglass Fiberglass <br /> Piping Manufacturer: Smith Smith Smith <br /> Piping Diameter: 3" 3" 3" <br /> Length of Piping Run: Aprox 70' Aprox 20' Aprox 20' <br /> Product Stored: Vent Vent Vent <br /> Method and location of Fiberglass Fittings/Air valve Fiberglass Fittings/Air valve Fiberglass Fittings/Air valve <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 15 minutes 15 minutes 15 minutes <br /> starting test: <br /> Test Start Time: 9:30am 9:30am 9:30am <br /> Initial Reading(RI): 5 PSI 5 PSI 5 PSI PSI <br /> Test End Time: 10:30am 10:30am 10:30am <br /> Final Reading(RF): 5 PSI 5 PSI 5 PSI PSI <br /> Test Duration: 1 hour 1 hour 1 hour <br /> Change in Reading(RF-Ri): 0 0 0 <br /> Pass/Fail Threshold or 0 0 <br /> Criteria: <br /> Test Result: QPass ❑Fail [DPass ❑Fail J Pass ❑Fail []Pass ❑Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />