My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FLAG CITY
>
14931
>
2300 - Underground Storage Tank Program
>
PR0506221
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 11:34:55 AM
Creation date
9/22/2020 2:00:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506221
PE
2361
FACILITY_ID
FA0007287
FACILITY_NAME
BAI PETRO INC. #83680
STREET_NUMBER
14931
Direction
N
STREET_NAME
FLAG CITY
STREET_TYPE
BLVD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
14931 N FLAG CITY BLVD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for LODI OIL INC ARCO #183680 as of May 06, 2020. <br /> Open violations from May 09, 2019 inspection <br /> G2 - This violation was corrected ❑ This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will b taken to correct violation: <br /> r Violat on ##307 -M itoring system of the interstitial space of a double walled system not maintained. <br /> Per the technician,the diesel annular sensor failed to activate an audible and visual alarm when tested and, <br /> therefore,the tank is not monitored. The interstitial space shall be monitored with a monitoring system connected to <br /> an audible and visual alarm system. Immediately contact a properly licensed,trained, and certified contractor to <br /> replace the failed component with a functional component(LG 11a-x listed, if applicable), under permit and <br /> inspection of the EHD if needed. <br /> Er This violation was corrected ❑ This violation will be corrected by(date): <br /> ❑ Supporting documents included "`S -- <br /> Describe actions taken or will be taken to correct violation: 5Uo <br /> I al VU Q <br /> Lhiolation#314-Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br /> containment shall be provided for all single-walled UST components. Immediately provide approved secondary <br /> containment for the filters under permit and inspection by the EHD. <br /> t( This violation was corrected This violation will be corrected by (date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: Pr V oJ-eI-- �� ,' a <br /> t �u" f Q <br /> Violation ##315-Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul <br /> 2003). <br /> Liquid was observed in the diesel STP sump,the diesel fill sump, and all UDCs except 718 were wet. If water could <br /> enter into the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> The service technician removed the liquid from the diesel sumps. Ensure that all sumps and annular spaces are <br /> maintained free of liquid. <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.