Laserfiche WebLink
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA#fi17 1 15237 N Thornton Rd Lodi Aril 23 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) I Biennial 0.1 gph line integrity test for single-walled gravity piping not performed(pre-Jan 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation n V n R -i COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms are not current in CERS. <br /> -The tank form for 87 Tank#4 incorrectly states the turbine sump is double-walled. All sumps at this facility are <br /> single-walled. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The monitoring plan for the 87 Tank#1 does not list a leak detector. A leak detector is shown for this tank on the <br /> monitoring site plan (map)and was observed on site. <br /> -The monitoring plans for all five tanks list the panel as a TLS-350. The panel on site is a TLS-350 Plus. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. <br /> -The map included incorrect leak detector information, showing a leak detector on 87 tank#3. No leak detector was <br /> observed on this tank. <br /> A site plan must be submitted identifying the locations where monitoring will be performed. Immediately log into the <br /> California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST <br /> Monitoring Site Plan. <br /> This is a repeat violation, Class II. <br /> 118 CCR 2715(a)(1)(A), 2715(a)(2) Failure to submit the "Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form was not found in CERS. This form <br /> must be uploaded to the California Environmental Reporting System (CERS). Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov and upload the Underground Storage Tank <br /> Statement of Understanding and Compliance Form for this facility. <br /> This is a minor violation. <br /> FA0012979 PR0517272 SCO01 04/23/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />