r- <br /> PLUMBING NOTES <br /> O <br /> 1. ALL WORK AND MATERIALS SHALL MEET THE 0ROOM FINISH SCHEDULE F <br /> REQUIREMENTS OF THE 2016 CALIFORNIA CODE, U) <br /> BUILDING CODE, AND MECHNICAL CODE, LOCAL w <br /> J °. . .... <br /> CODE, AND EQUIPMENT MANUFACTUR'S O 1= p z <br /> INSTALLATION INSTRUCTION. w O <br /> z0 � <br /> 2. INSTALL CLEANOUT FOR HORIZONTAL WASTE PIPE _ O <br /> z <br /> PER UPC. z <br /> Y (n ❑ <br /> 3. SLOPE HORIZONTAL WASTE AND VENT PIPE NO NOTE N <br /> LESS THAN 1/4 " PER FOOT. VENT PIPE SHALL BE CONCRETE CEMENT W/TWO COATS OF CLEAR COAT COMMERCIAL GRADE SEALER E <br /> FREE FROM SAG. E NON-SLIP CIRAMIC TILE, PATCH&REPAIR AS NEEDED w ii <br /> _ O N E <br /> SOLID SHEET VINYL, COMMERCIAL GRADE ALTRO STRONHOLD 30 OR EQUAL). HEAT WELD SEAMS O W o <br /> 4. EQUIPMENTS LOCATIONS SHALL BE FIELD *_6_6 6"X 6" QUARRY TILE W/GRAEASE RESISTANT EPDXY GROUT � lY <br /> VERIFIED. _ NSF APPROVED PANEL INSULATED FLOOR <br /> _ 4"INTEGRAL METAL COVE,APPLY COMMERCIAL GRADE SEALANT BETWEEN BASE AND PANEL <br /> 4"COVED CERAMIC TILE,CONTINUOUS W/3/8" RAD. W <br /> 5. INSULATE HOT WATER PIPE MINIMUM 1/2 COVED WOOD MOLDING U) <br /> 009 4"COVED QUARRY T[LE,CONTINUOUS.W/3/8"RAD. 3 m <br /> 6. PROVIDE SHUT OFF VALVES AT THE WATER o a� <br /> HEATER AND EACH MAJOR BRANCH. • 5/8"TYPE"X" GYPSUM BOARD 6 g m <br /> CERAMIC TILE <br /> UI U Y CD LO <br /> • • SMOOTH FINISHES, WITHOUT TEXTURE; PAINTED SURFACES TO BE OIL OR ENAMEL BASED SEMI GLOSS <br /> J o 2 o Q <br /> 7. STUB OUT ALL SERVICES PER EQUIPMENT STUCCO GALVANUZED STEEL Q � � L " <br /> MANUFACTURE'S RECOMMENDATIONS. • STAINLESS STEEL SHEET J W o N o <br /> 0.0.. FRP BOARD, CERAMIC TILE,CR EQUAL�AREAS BEHIND SINKS&OTHER WET EQUIPMENT a R o E <br /> • GYPSUM BOARD CEILING PAINT AS NEEDED <br /> 8. FLOOR SINKS AND OTHER INDIRECT WASTE SMOOTH,CLEANABLE, NO TEXTURE, LITE COLOR,OIL OR ENAMEL BASED PAINT c:Z <br /> RECEPTORS SHALLBE READILY ACCESSIBLE FOR T-BAR GYP BOARD CEILING W/REMOVABLE SMOOTHNVASHABLE TILE J <br /> CLEANING. WHERE FLOOR DRAINS ARE UTILIZED, THE • • E coo <br /> T-BAR GYPSUM BOARD CEILING W/ACOUSTICAL CORRUGATED TILE LAY-IN 3 w <br /> STUCCO GALVANIZED STEEL U a <br /> FLOOR SURFACES MUST BE SLOPED 1:50 TO THE EXPOSED CEILING U <br /> DRAINS. <br /> w <br /> FINISH NOTES o m <br /> 9. PROVIDE 6" METAL LEGS OR METAL PLATFORM FOR a m 3 <br /> WATER HEATER. 1. FRP OR CERAMIC TILE TO EXTEND TO 4" ABOVE COVED BASE AT ALL SINK AND OTHER AREAS SUBJECT TO Z aco a <br /> MOISTURE (& EXTENDING 2' PAST EACH SIDE) o o <br /> 10. MOP SINK MUST BE FLOOR MOUNTED. 2. STAINLESS STEEL WALL COVERING BEHIND COOKING EQUIPMENT TO BOTTOM EDGE OF HOOD <br /> 3. EXISTING TO REMAIN; PATCH, REPAIR, AND REPLACE TILE AS NECESSARY Date: <br /> 11. EXHAUST HOODS MUST MEET ALL MECHANICAL 4. 1 COAT BEHR NO. 991 CONCRETE ETCHER & RUST REMOVER FOR PROPER ADHESION/PENETRATION & 2 COATS <br /> CODE REQUIREMENTS. CANOPY HOODS SHALL BEHR WET LOOK SEALER. 5/25/20 <br /> EXTEND 6" BEYOND ALL SIDES OF COOKING 5. REPLACE ANY ACCOUSTICAL TILE IN FOOR PREP AREAS WITH SMOOTH/WASHABLE TILE <br /> EQUIPMENT AS MEASURED FROM INSIDE EDGE OF 6. PROVIDE GYPSUM BOARD OVER STORAGE AREA WOOD STUDS, AND SEAL ANY CRACKS IN ROOM TO BE VERMIN I Scale: <br /> THE GREASE TROUGH. ADEQUATE MECHANICAL PROOF. <br /> MAKE-UP AIR MUST BE PROVIDED TO PRODUCE A As Shown <br /> BALANCED SYSTEM. Sheet No: <br /> :A9 <br />