REVISIONS <br /> GENERAL NOTES NO. DESCRIPTION DATE <br /> 1. THIS SHEET TO BE USED BY THE GENERAL CONTRACTOR FOR <br /> INFORMATION AND CLARIFICATION. REFER TO SPECIFICATIONS. <br /> 2. SCOPE OF WORK TO BE COMPLETED BY WINCO'S BMS CONTRACTOR <br /> UNLESS OTHERWISE NOTED. BMS CONTRACTOR TO SUPPLY, <br /> INSTALL, AND TERMINATE ALL LOW VOLTAGE WIRE. ALL CONTROL <br /> WIRING, DEVICES, AND EQUIPMENT SHOWN ON BMS SHEETS TO BE <br /> DAMPER/ACTUATOR MOTOR SCHEDULE SUPPLIED AND INSTALLED BY BMS CONTRACTOR UNLESS <br /> OTHERWISE NOTED. <br /> MINIMUM 3. ELECTRICAL CONTRACTOR TO COORDINATE CONDUIT <br /> EQUIPMENT LOCATION DAMPER SIZE QUANTITY TORQUE PER CONTROL FAIL SAFE NOTES REQUIREMENTS WITH BMS CONTRACTOR PRIOR TO BEGINNING <br /> WORK. WHERE NOT SUBJECT TO MECHANICAL DAMAGE, CABLE TO <br /> 7 8 N O. MOTOR SIGNAL BE ROUTED FREE AIR. WHERE MECHANICAL DAMAGE IS POSSIBLE <br /> AND WITHIN 10 FT OF FINISHED FLOOR, ELECTRICAL CONTRACTOR <br /> H Y D R O N I C LOOP TO PROVIDE CONDUIT FOR PROTECTION. <br /> SUPPLIED AND INSTALLED BY 4. ALL SINGLE PHASE MOTORS (FANS, PUMPS, ETC.) SHOULD BE ON A <br /> CCV-1 CONDENSER 1 0-10 VDC PIPING CONTRACTOR 20A OR 30A POWER RATED RELAY FUNCTIONAL DEVICES 'RIB'OR <br /> 3-WAY VALVE APPROVED EQUAL, AS APPROPRIATE, FURNISHED AND INSTALLED <br /> BY BMS CONTRACTOR. 3 PHASE PUMPS AND FANS TO HAVE VFD OR <br /> STARTER BY ELECTRICAL CONTRACTOR. 24V INTERFACING RELAY <br /> (E) MINI RACK A FURNISHED AND INSTALLED BY BMS CONTRACTOR WHERE ARCH.PROJECT NO. <br /> REQUIRED. 2004 <br /> 5. ALL 2 WIRE DEVICES TO UTILIZE BELDEN 8761 CABLE OR APPROVED <br /> EQUAL, UNLESS NOTED OTHERWISE. DRAWN <br /> 6. ALL 3 WIRE DEVICES TO UTILIZE BELDEN 8771 CABLE OR APPROVED RS <br /> EQUAL, UNLESS NOTED OTHERWISE. CHECKED <br /> 7. ALL 4 WIRE DEVICES TO UTILIZE BELDEN 9418 CABLE OR APPROVED MS <br /> (E) MINI RACK B EQUAL, UNLESS NOTED OTHERWISE. <br /> 8. DEVICES WITH DISPLAYS TO BE MOUNTED TO ALLOW FOR SUBMITTAL DATES <br /> UNOBSTRUCTED VIEWING. <br /> 9. REFER TO OPTO-22 DOCUMENTATION FOR TERMINATION 06/11/20 <br /> INFORMATION. <br /> (E) MINI RACK C KEYED NOTES OTB DATE <br /> F BSS PANEL <br /> 1. TEMP SENSOR ON BACK OF STAINLESS STEEL PLATE(ACI <br /> PART#A/CP-SP OR APPROVED EQUAL)FURNISHED AND <br /> THIN CLIENT INSTALLED BY BMS CONTRACTOR. MOUNT 48" A.F.F. z o <br /> 2. MIXED AIR TEMPERATURE TO BE MEASURED BETWEEN THE o a 'o w o <br /> FILTERS AND COOLING COIL. H a F z a <br /> - - - Oa 'u o <br /> 4. REMOTE ALARM WITH SILENCE. MOUNT SENSOR AT 48" A.F.F. 9 o w>=1c� W <br /> K K zaa �Qz z <br /> SEEBMS3-2. <br /> REMOTE DEFROST PANEL <br /> 0a Awow a <br /> MAIN BMS 5. DUCT TEMPERATURE SENSOR ACI PART#A/CP-D-XX OR w z w E <br /> ca <br /> APPROVED EQUAL. XX IS PICKED FROM AVAILABLE MODEL <br /> �oaW�A �z� z o.� � <br /> NUMBER SUCH THAT THE PROBE IS OF SUFFICIENT LENGTH A Q z o 13 N <br /> TO REACH THE APPROXIMATE CENTER OF EACH QUADRANT) z W Q Q o x w " 3 co <br /> FURNISHED AND INSTALLED BY BMS CONTRACTOR. o Q H � o <br /> 7 8 8. BMS CONTRACTOR TO PROVIDE FOUR TEMPERATURE w � .'w'o o o <br /> SENSORS PER DUCT AS NOTED, WIRED IN SERIES/PARALLEL. A w <br /> LOCATE INDIVIDUAL SENSORS SO THAT THE SENSINGIvo <br /> ELEMENT IS IN THE APPROXIMATE CENTER OF EACH F. F. UA 0 3° <br /> REFRIGERATION PLATFORM 'A' 10. QUA RDNT. <br /> DETECTOR PROVIDED BY FIRE ALARM CONTRACTOR N <br /> 3/16" = 1'-0" AND INSTALLED BY MECHANICAL CONTRACTOR. BMS M O <br /> CONTRACTOR TO WIRE SMOKE SHUTDOWN TO A FACP RELAY Y.1 O — <br /> PROGRAMMED BY FIRE ALARM CONTRACTOR. COORDINATE _ <br /> WITH FIRE ALARM CONTRACTOR. a r0 <br /> 11. CONTROLS CONNECTION BY BMS CONTRACTOR. CONDUIT TO 0 co w <br /> CONCEAL AND PROTECT BY ELECTRICAL CONTRACTOR. O <br /> COORDINATE WITH BMS CONTRACTOR. O u <br /> O N <br /> 12. EBTRON FLOW METER PROVIDED BY BMS CONTRACTOR AND ♦ ♦ x o <br /> INSTALLED BY MECHANICAL CONTRACTOR. EBTRON GOLD V y �_7 O <br /> SERIES. <br /> LLJ <br /> 13. DX LEAVING AIR TEMPERATURE TO BE MEASURED BETWEEN w Z O <br /> THE COOLING COII.AND THE RECLAIM HEAT COIL. BMS z W <br /> CONTRACTOR SUPPLIED AND INSTALLED. cow <br /> O <br /> 14. ACTUATOR(S) PROVIDED AND INSTALLED BY BMS Z ,O <br /> 6.2 6.4 7 8 9 10 CONTRACTOR. SEE DAMPER MOTOR SCHEDULE FOR <br /> QUANTITY AND TYPE. Q LV <br /> 16. BMS CONTRACTOR TO INSTALL OWNER PROVIDED THIN d 3: co <br /> CLIENT AND RELATED HARDWARE. O <br /> JL <br /> 0 <br /> T 17. HIGH TEMPERATURE 10K TYPE 2 SENSOR. MOUNT IN DUCT N W <br /> FURNACE DISCHARGE AIR. LF) <br /> \_7 <br /> �/ Z <br /> - - - - - - - - - - - - - - - B M S LEGEND <br /> i FESS/ <br /> ® � <br /> T SYMBOL DESCRIPTION Qc`Op H. <br /> M 6 MOTORIZED DAMPER <br /> oc 31 �• <br /> 8 TS TEMPERATURE SENSOR (2-WIRE <br /> T T 'w FC F12/31/21\P't <br /> DEVICE) qT HAN Q� <br /> F pF SFO <br /> 2 3 SD DUCT SMOKE DETECTOR CAS <br /> EF (N)RTU-2 PROVIDED BY FIRE ALARM <br /> O O <br /> 1 Ts O <br /> MECHANICAL CONTRACTOR FORY 06/11/20 <br /> T AUTOMATIC UNIT SHUT-DOWN. <br /> 1 <br /> Q PHOTOSENSOR <br /> _❑- O 'a= ALARM <br /> (N)RTU-3 Ts O <br /> 1 EQUIPMENT CALLOUT <br /> O OTS _ KH7O <br /> o <br /> (N)RTU-1 FUNCTIONAL DEVICE •--I <br /> CURRENTSENSOR <br /> O <br /> REMOTE BMS PANEL#1—' ABBREV. DESCRIPTION <br /> H HOOD T <br /> - - EF EXHAUST FAN <br /> WH WATER HEATER O O <br /> CP CIRCULATION PUMP <br /> Q <br /> O <br /> O <br /> o��� <br /> FRONT MEZZANINE <br /> O <br /> 3/16" = 1'-0" <br /> OPTO ANALOG 11 NOTE: <br /> INPUT DRILLING TOP OF CABINET <br /> IS PROHIBITED. <br /> BMS PANEL <br /> 3"C FOR COMM WIRING <br /> PROVIDED BY 3/4"C FOR 120V POWER <br /> ELECTRICAL CONTRACTOR <br /> 6"x6"D GUTTER, <br /> LENGTH AS REQUIRED. <br /> PARALLEL SERIESQUADRANT PROVIDED BMS <br /> CONTRACTOO R. SHEET TITLE <br /> 1 TEMP SENSOR WIRING DIAGRAM s TYPICAL BMS PANEL DETAIL BMS DETAILS <br /> NTS NTS <br /> & ENLARGED <br /> PLATFORM <br /> PLAN <br /> M <br /> O <br /> �.,., SHEET <br /> BMS20 <br /> N <br /> O <br /> O <br />