Laserfiche WebLink
REVISIONS <br /> GENERAL NOTES NO. DESCRIPTION DATE <br /> 1. THIS SHEET TO BE USED BY THE GENERAL CONTRACTOR FOR <br /> INFORMATION AND CLARIFICATION. REFER TO SPECIFICATIONS. <br /> 2. SCOPE OF WORK TO BE COMPLETED BY WINCO'S BMS CONTRACTOR <br /> UNLESS OTHERWISE NOTED. BMS CONTRACTOR TO SUPPLY, <br /> INSTALL, AND TERMINATE ALL LOW VOLTAGE WIRE. ALL CONTROL <br /> WIRING, DEVICES, AND EQUIPMENT SHOWN ON BMS SHEETS TO BE <br /> SUPPLIED AND INSTALLED BY BMS CONTRACTOR UNLESS <br /> OTHERWISE NOTED. <br /> 3. ELECTRICAL CONTRACTOR TO COORDINATE CONDUIT <br /> REQUIREMENTS WITH BMS CONTRACTOR PRIOR TO BEGINNING <br /> 1 2 3 4 5 6 7 8 9 10 11 WORK. WHERE NOT SUBJECT TO MECHANICAL DAMAGE, CABLE TO <br /> BE ROUTED FREE AIR. WHERE MECHANICAL DAMAGE IS POSSIBLE <br /> AND WITHIN 10 FT OF FINISHED FLOOR, ELECTRICAL CONTRACTOR <br /> TO PROVIDE CONDUIT FOR PROTECTION. <br /> 4. ALL SINGLE PHASE MOTORS (FANS, PUMPS, ETC.) SHOULD BE ON A <br /> 20A OR 30A POWER RATED RELAY FUNCTIONAL DEVICES 'RIB'OR <br /> APPROVED EQUAL, AS APPROPRIATE, FURNISHED AND INSTALLED <br /> BY BMS CONTRACTOR. 3 PHASE PUMPS AND FANS TO HAVE VFD OR <br /> POWER MONITORING PANELS 1 & 2 01 1 1 1 STARTER BY ELECTRICAL CONTRACTOR. 24V INTERFACING RELAY <br /> FURNISHED AND INSTALLED BY BMS CONTRACTOR WHERE ARCH.PROJECT NO. <br /> IL:p ) REQUIRED. 2004 <br /> 5. ALL 2 WIRE DEVICES TO UTILIZE BELDEN 8761 CABLE OR APPROVED <br /> I I I I I I I I I I <br /> EQUAL, UNLESS NOTED OTHERWISE. DRAWN <br /> 6. ALL 3 WIRE DEVICES TO UTILIZE BELDEN 8771 CABLE OR APPROVED RS <br /> 0 ❑ ° EQUAL, UNLESS NOTED OTHERWISE. CHECKED <br /> 7. ALL 4 WIRE DEVICES TO UTILIZE BELDEN 9418 CABLE OR APPROVED MS <br /> - - - - - - - - - - - - - - 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -IF EQUAL, UNLESS NOTED OTHERWISE. <br /> 9. DEVICES WITH DISPLAYS TO BE MOUNTED TO ALLOW FOR SUBMITTAL DATES <br /> UNOBSTRUCTED VIEWING. <br /> 1 1 1 1 1 1 1 1 1 10. REFER TO OPTO-22 DOCUMENTATION FOR TERMINATION 06/11/20 <br /> INFORMATION. <br /> o 'I <br /> I I I I I IIE I <br /> 6 OTB DATE <br /> 0 0 0 Ll ° <br /> ° 1 1ill KEYED NOTES <br /> I I <br /> 0 0 ° 1. TEMPERATURE SENSOR/HUMIDITY SENSOR(ACI PART# <br /> IL A/RH2-CP-R2) FURNISHED AND INSTALLED BY BMS U o <br /> CONTRACTOR. MOUNT SENSOR AT 8'-0" A.F.F. o <br /> 2. TEMP SENSOR ON BACK OF STAINLESS STEEL PLATE(ACI PART o a o ti a <br /> wFz� <br /> ® ° BMS CONTRACTOR. MOUNT AT 48" A.F.F. UNLESS OTHERWISE o a U>'� ¢ ca a <br /> #A/CP-SP OR APPROVED EQUAL)FURNISHED AND INSTALLED BY U a W - a o <br /> 0 0 W O '� o <br /> z'A' p q z z Y <br /> NOTED. q��o � •, <br /> M - - - - - - - - - - - - 3. DRILL MAX 1/2" HOLE AT TOP OF COLUMN AND AT SENSOR a 6 o I w <br /> ° ° LOCATION. ROUTE CONTROL CABLES INSIDE COLUMN. w w yay� w w A <br /> O va u x a g U (� ? o°°o <br /> 4. OUTSIDE HUMIDITY/TEMPERATURE SENSOR(ACI PART# P Q Q o z o I z y 3co <br /> A/RH2-I 0K-CP-O OR APPROVED EQUAL) FURNISHED AND 'n a W a° W <br /> 7pw � �� L) o <br /> ° <br /> INSTALLED BY BMS CONTRACTOR. MOUNT SENSOR ON THE ��,q �� w v � � o � a <br /> ° <br /> OUTSIDE WALL BETWEEN ROOF DECK AND BOTTOM CORD. � w w � �o <br /> q � Uwz0. gvn <br /> cs _ s 5. OUTSIDE LIGHT LEVEL SENSOR(PART#MAS/O-2X-0T OR mow, o x o <br /> ° APPROVED EQUAL) FURNISHED AND INSTALLED BY BMS o °o <br /> CONTRACTOR. MOUNT SENSOR BETWEEN ROOF DECK AND <br /> 14 0 <br /> ° <br /> V\ BOTTOM CORD FACING NORTH. <br /> I I I � I I �\. I I I V♦ � <br /> 2 J 6. REMOTE 3ALARM WITH SILENCE. MOUNT SENSOR AT 48" A.F.F. <br /> W O � <br /> 0 (N RTU-5 ° 7. CO2 SENSOR(ACI PART#ESENSE-R OR APPROVED EQUAL) Q 1- <br /> FURNISHED AND INSTALLED BY BMS CONTRACTOR. MOUNT o <br /> o z � SENSOR AT 8 0 A.F.F. O � n l <br /> 8. DHW EOL TEMPERATURE SENSOR. RE: BMS3 FOR SENSOR TYPE. (5 cW CC) <br /> O CD <br /> o ° o ® 1 ° 9. TEMPERATURE SENSOR(ACI PART#A/CP-SP OR APPROVED Q u = a m N <br /> z)n nn nn EQUAL)FURNISHED AND INSTALLED BY BMS CONTRACTOR. x o <br /> o 1 °1 ❑� T 71 - - - I MOUNT SENSOR AT 8'-0: A.F.F. � Q <br /> m - — - — - — - — - — - — - — - - - - - 10. LIGHT LEVEL SENSOR FOR LIGHTING CONTROL(PLC y w <br /> MULTIPOINT MAS/I-1X-OT). INSTALL SENSOR CENTERED AT ROOF � � Z <br /> w c� <br /> ° BETWEEN SKYLIGHT WELLS. PHOTO SENSOR IS TO BE POINTED � � � W <br /> 70 DOWN AND CENTERED WITHIN AN AISLE SO THAT IT IS READING <br /> THE REFLECTIVE LIGHT LEVEL FROM THE FLOOR. Z u <br /> 14. ACTUATOR(S) PROVIDED AND INSTALLED BY BMS <br /> CONTRACTOR. SEE DAMPER MOTOR SCHEDULE FOR QUANTITYQ W U) r� <br /> I 1 1 1 I � I o I I AND TYPE. T � a d o <br /> 3 1 3 <br /> ® o Tso Tso <br /> - - - - - <br /> - - BMSLEGEND <br /> Z <br /> )-RTU-10- <br /> a SYMBOL DESCRIPTION <br /> ° <br /> 0 <br /> 00 <br /> 100 O HUMIDITY SENSOR (3-WIRE DEVICE) c`O Q pFHSMI <br /> ° 1 3 �`�Q,PQ.�c <<F F <br /> a <br /> TsT T <br /> TS TEMPERATURE SENSOR (2-WIRE c� m <br /> I I I I I I I I I OWC 31 � <br /> (N)RTU-9 F <br /> DEVICE) <br /> Ps PRESSURE SENSOR <br /> cPj F�HAN�C"P���P <br /> ° ° ° ° °°1° ° OP PHOTO SENSOR cx <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - � 06/11/20 <br /> CO2 CARBON DIOXIDE <br /> SENSOR (3-WIRE DEVICE) <br /> CS FUNCTIONAL DEVICE <br /> m o o CURRENTSENSOR <br /> o 0 0010 0 <br /> m ABBREV. DESCRIPTION <br /> m � ❑ <br /> ❑ m1 VAV VARIABLE AIR VOLUME UNIT <br /> EWH ELECTRIC WALL HEATER O <br /> H HOOD <br /> ° fo <br /> EF EXHAUSTFAN <br /> 0000 0 <br /> o o WH WATER HEATER <br /> 0 0 0 oO <br /> CP CIRCULATION PUMP T <br /> 000000 L100000 <br /> G — — — — — — — — ° — — — r - - — —— — — — — r — — — — — — — � — — — — — — — r — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — G <br /> o 0 00 0 00 0 00 0 0 <br /> 0 0 0 0 0 00 O <br /> 0 0 0 <br /> °(:DF - Lp — — — — — — — L T — — — — — — — — — — I 1 0 0 1 <br /> I I I I I I I I <br /> � � U <br /> 7 000 O <br /> 3 ❑ ° ` O <br /> 1 ❑ 0 O <br /> Ts H O <br /> IQ AT AU o U <br /> � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> I AF FIF-1 F-177 <br /> ❑❑ <br /> o 0 0 <br /> I I I I I I I I I <br /> ❑❑❑ I I I I I I I <br /> ❑ ❑ <br /> D - - - - - - - - - - - - - - - - - - - - - - - - <br /> - - - - - - - - - - - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> itl <br /> I I I I I I I I <br /> °I T I <br /> S CS <br /> I I I I I I I I <br /> I 1 1 1 cs <br /> I 111 11-4 111 <br /> 0 <br /> Hill <br /> 8 O <br /> T T T T T T <br /> I I I I I I I I <br /> I ❑ ❑ <br /> 0 0 0 0 0 0 0 0 0 00 0 0 0 ° <br /> O <br /> I I I❑ I I I (N)RTU-4 <br /> (N)�TU-8 (N RTU-7 <br /> ° � n <br /> I I I I I I I I ® I <br /> - - - <br /> - - - - - - _ _ - - - - - - - - - - - - - - - - - - - - � - - _ - - - - - - - - - - - - - - - - - - - - - � <br /> 0 0 0 0 ❑ <br /> o El ❑� CS <br /> om (N) <br /> B - - - - - - - - - - - - - - - - - - - - - o <br /> I I I I I I I ❑ I <br /> ° <br /> ❑ o ❑ 0 <br /> ° ° ° I I I I I ° I � I I ❑ I <br /> o <br /> Qo <br /> ° ❑ EEI� I <br /> Ll � o BMS PLAN <br /> -7 <br /> ° D o <br /> M — — — — — F-7 <br /> L7S <br /> M <br /> SHEET <br /> BMS PLAN � <br /> -- " _ l'-O" <br /> BMSI <br /> O <br /> O <br /> 1 2 3 4 5 6 7 8 9 10 11 <br />