10'-0" MINIMUM FROM ADJACENT BUILDINGS AND REVISIONS <br /> PROPERTY LINES, AIR INTAKES, OR PARAPETS <br /> AND 5'-0" MINIMUM FROM VERTICAL ELEMENTS NO. DESCRIPTION DATE <br /> 10'-0" MINIMUM FROM ADJACENT BUILDINGS AND OF THE SAME BUILDING. <br /> PROPERTY LINES, AIR INTAKES, OR PARAPETS (CLEARANCE REQUIRED IN ALL DIRECTIONS) <br /> AND 5'-0" MINIMUM FROM VERTICAL ELEMENTS <br /> OF THE SAME BUILDING. <br /> (CLEARANCE REQUIRED IN ALL DIRECTIONS) UPBLAST <br /> DOWNBLAST UPBLAST EXHAUST FAN <br /> 16 GA GALV 40" MIN RE: M2.1-9 <br /> STEEL <br /> PROVIDE HINGED BASE EXHAUST DUCT <br /> 2 LAYERS OF FIREMASTER CONNECT TO <br /> DUCT WRAP HOOD OPENING AS <br /> 30" MIN. ABOVE <br /> ROOF SURFACE REQUIRED <br /> EXHAUST DUCT 16 MIN. 18 GA STAINLESS 1/2" ROD WITH THREADED ENDS FOR <br /> GA. WELDED STEEL ° STEEL ° SEISMIC BRACING. BOLT TO ROOF <br /> LEVEL ROOF o ° ° GREASE HOOD. ° STRUCTURE AND TO EXHAUST HOOD. <br /> LEVEL ROOF CURB WET CHEMICAL (4 PER HOOD, 1 AT EACH CORNER) <br /> CURB NOZZLE AS REQUIRED. INTEGRAL 3" <br /> PREFABRICATED. PREFABRICATED. COORDINATE WITH AHJ ARCH.PROJECT NO. <br /> TO BE FURNISHED TO BE FURNISHED 18 MIN. ABOVE <br /> WITH EQUIPMENT WITH EQUIPMENT ROOF SURFACE CLEARANCE 2004 <br /> w BETWEEN <br /> 14" MIN., RE: A7.1-6 HOOD AND WALL. DRAWN <br /> EXTRUDED STAINLESS STEEL <br /> ALUMINUM, FASTEN HOOD TO RE AIOEL SS <br /> TIERED LOWERS: CURB (2) PLACES CHECKED <br /> ROOF DECK BACWHERE_APPLICABLE INSECT <br /> ROOF DECK A7� <br /> 0 EACH SIDE FINISH FLOOR RD <br /> INSECT SCREEN h/ PRE-FABRICATED <br /> NOTE: EXHAUST DUCT CURB. RE: A7.1-6 SUBMITTAL DATES <br /> DETAIL TYPICAL FOR UP-BLAST FRONT VIEW SIDE VIEW <br /> OR DOWN-BLAST EXHAUST FAN NOTE: 06/11/20 <br /> 1. ALL AIR SPACES BETWEEN HOOD AND CEILING AND BETWEEN HOOD AND WALLS SHALL BE BLANKED OFF SOLID <br /> WIT14 GAGE MIN. STAINLESS STEEL PANELS. PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. <br /> GENERAL BUILDING EXHAUST TYPE II HOOD EXHAUST 2. VERTICAL DISTANCE BETWEEN COOKING SURFACE AND HOOD LIP SHALL NOT EXCEED 48" HORIZONTAL, OVERHANG OTB DATE <br /> SHALL NOT BE LESS THAN 6". <br /> 3. HOOD IS A UL-LISTED ASSEMBLY. REFER TO SCHEDULE. <br /> 4. FIRE SUPPRESSION PIPING TO MEET AHJ REQUIREMENTSTO COVER (2) FRYERS, (1) FUTURE FRYER AND (1) COMBI OVEN. <br /> I EXHAUST FAN DETAILS2 PENTHOUSE DETAIL <br /> NTS NTS DELUCHICKEN EXHAUST HOOD z° <br /> 9w ��u <br /> 3 oa4�o�a <br /> NTSha;� °z <br /> lu a o <br /> z z ° a <br /> a�q <br /> U <br /> w8x�86zw I Wcoo <br /> a <br /> WwamqEza Zo� �_ <br /> a W /a7 U g O c c N <br /> `uz© Z Y 3 N <br /> O <br /> �F¢U �U 0 Oc"i a <br /> Wfa� q o <br /> MECHANICAL CONTR. TO VERIFY&PROVIDE <br /> co <br /> IF NEEDED SHEETMETAL EXTENSION FROM ov�� °o <br /> RETURN AIR DUCT � �� � o3u <br /> BOTTOM OF DUCT TO RETURN AIR PLENUM <br /> ON BACK OF CASE. SEAL&MAKE AIRTIGHT. MECHANICAL CONTRACTOR TO FABRICATE & N <br /> INSTALL SHEET METAL EXTENSION FROM RETURN AIR DUCT M <br /> MANUAL DAMPER W O <br /> BOTTOM OF DUCT TO RETURN AIR PLENUM <br /> ON BACK OF CASE. SEAL&MAKE AIRTIGHT. Q n <br /> lk MANUAL DAMPER VENT DISCHARGE o <br /> MECHANICAL CONTRACTOR TO VERIFY & MECHANICAL CONTRACTOR TO PROVIDE & A MINIMUM OF 48" y <br /> PROVIDE IF NEEDED PLENUM COVER FOR TALL PLENUM VER FOR TOP, ABOVE THE ROOF OR VENT CAP, BIRD PROOF O C7 cW O <br /> TOP, SIDES, AND ENDS. FASTEN WITH INS U CO O O , 48" ABOVE ANY PARAPET (� N <br /> ANGLE ATTACHMENTS & SCREWS AS 12"x40" SIDES, AND ENDS. FASTEN SCREWS MECHANICAL CONTRACTOR SHALL <br /> O <br /> OR FRESH AIR INTAKE = Q m F <br /> AS REQUIRED. FIT AROUND COLUMNS SEAL ALL EDGES AFTER INSTALLATION x o <br /> REQUIRED. FIT AROUND COLUMNS AND AND SEAL TIGHT WITHIN 10 FEET GAS VENT: TYPE 'B' H <br /> SEAL TIGHT oo UL APPROVED FOR V] <br /> 1" CLEARANCE FROM ■ w <br /> _ • Who <br /> STORM COLLAR COMBUSTIBLES a 11, Z <br /> LLJ W cn <br /> ROUND STANDING SEAL WEATHER-TIGHT WITH CC LL-1 <br /> GONDOLA SHELVING COLLAR, 4" HIGH "PAR-BOND" GUTTER SEAL Z W < <br /> SEALED AIR SPACE REFRIGERATED CASE - CL <br /> GUSSET SUPPORT Q � O <br /> AS REQUIRED SOLDER STANDING COLLAR LV <br /> PLENUM WALL RE: A2 <br /> REFRIGERATED CASE CURB CAP: 22 GAGE TO CAP & SEAL WEATHER-TIGHT = o <br /> CROSS BREAK TOP AND o N <br /> SOLDER ALL JOINTS i— LL <br /> FLASHING: 3", FASTEN TO z <br /> CURB (2) PLACES EACH SIDE Q Ln O <br /> AIR FLOWAIR FLOW FINISH FLOOR z <br /> AIR FLOW FINISH FLOOR OJ z <br /> PRE-FABRICATED <br /> CURB BY GENERAL SUPPORT WEIGHT OF GAS <br /> CONTRACTOR VENT FROM STRUCTURE <br /> 8" CONTINUOUS SLOT SEALED AIR SPACE <br /> O OPENING FESS/ESS/ <br /> OPENING IN RETURN AIR WALL �,l <br /> IN RETURN AIR WALL c� m <br /> 8 5 <br /> P: 12/31/21 <br /> 4 RETURN AIR PLENUM BETWEEN CASE & GONDOLA 5 RETURN AIR PLENUM BETWEEN CASES 6 GAS VENT DETAIL `r� �F�HAN\CP���P <br /> qTF OF CF�Q <br /> NTS NTS NTS <br /> 06/11/20 <br /> O <br /> � 0 <br /> WELDED DUCT FLANGE HINGED BASE O <br /> H <br /> FASTEN 2 PLACES GE SILICONE SEAL 1 <br /> EACH SIDE 40" MIN. ABOVE <br /> VENTED CURB ROOF SURFACE <br /> EXTENTION <br /> 11" MIN. CURB \ <br /> EXTENTION �� 0 <br /> 18" MIN. ABOVE 0 <br /> ROOF SURFACE �{ O <br /> o O <br /> 14" MIN. CUR <br /> B, <br /> o O <br /> ROOF DECK PREFABRICATED CURB ° <br /> COUNTER FLASH BY MECHANICAL <br /> (TYP. ALL SIDES) CONTRACTOR <br /> MINIMUM 2 LAYERS 1-HR. EXHAUST DUCT o <br /> FIRE RATED 3M FIREMASTER RE: A7.1-9 <br /> DUCT WRAP SYSTEM 0 <br /> EXHAUST DUCT: <br /> 16 GAGE, WELDED TOP OF HOOD NOTE: <br /> LIQUIDTIGHT, WITH TOP 1. FIRE SUPPRESSION PIPING TO MEET AHJ REQUIREMENTS TO BE <br /> FLANGE TURNED OUT OVER PLACED DIRECTLY OVER(2) FRYERS, (1) FUTURE FRYER AND (1) <br /> TOP OF FAN PEDESTAL COMBI OVEN. RE:FP2 FOR EXACT EQUIPMENT LAYOUT PRIOR TO <br /> INSTALLATION. <br /> 7 TYPE 1 EXHAUST FAN DETAIL 8 FIRE PENDANT PLACEMENT <br /> NTS NTS <br /> SHEET TITLE <br /> MECHANICAL <br /> DETAILS <br /> N <br /> N <br /> M SHEET <br /> M2910 <br /> 0 <br /> N <br /> O <br /> N <br /> O <br />