My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
3105
>
2200 - Hazardous Waste Program
>
PR0505946
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2020 2:12:15 PM
Creation date
9/24/2020 1:14:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0505946
PE
2227
FACILITY_ID
FA0003680
FACILITY_NAME
CALIFORNIA TANK LINES INC
STREET_NUMBER
3105
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17512028
CURRENT_STATUS
01
SITE_LOCATION
3105 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AST SPob1 ANNUAL INSPECTION <br /> Item Task Status <br /> 15.3.4 Scienoid waives Cycle power to valve and confirmed operation. (Electrical r Yes No N/A <br /> solenoids can be verified by listening to the plunger opening <br /> and closing. If no audible confirmation,the valve should be <br /> Inspected for the presence and operation of the plunger)(enter I <br /> manufacturer and model number in Comments if available) <br /> 5.3.5 f=ire and shear valves a. Manually cycle the valve and confirmed components are l�Yes �`No N/A <br /> moving freely and that the valve handle or lever has clearance <br /> to allow valve to close completely.(enter manufacturer and <br /> model number in Comments if available) <br /> b.Vaives must not be wired in open position. Yes i-No I>✓N/A <br /> c. Make sure fusible element is in place and correctly F Yes r'No W N/A <br /> positioned. <br /> I d. Be sure test ports are sealed with plug after testing is i~Yes r-No 1✓N/A <br /> complete and no temporary test fixture or component remains i <br /> connected to valve. <br /> Comments: <br /> 5.4 tntersttal leak detection Check condition of equipment, including: <br /> equipment ® Make: ,Model: <br /> • The window is clean and clear in sight leak gauges. r-Yes i"No W N/A <br /> o The wire connections of electronic gauges for tightness and .es No WN/A <br /> corrosion. 1 <br /> Activ,3te the test button, if applicable. <br /> i Yes :�No TV N/A <br /> !5.5 SpdB?l containment boxes I a. Confirmed SB is free of corrosion, damage, or wear that j Tr Yes i No W N/A <br /> on fila pipe has compromised the ability of the unit to perform spill <br /> 1 I containment functions(enter manufacturer and model number <br /> in Comments if available) <br /> J b. Confirmed connections to the AST are tight, and all bolts, r-Yes r-No r N/A <br /> d nuts, washers are in good condition- <br /> c. Confirmed drain valves are operational. T-Yes r No I✓NIA <br /> 5.6 Strainer i a. Confirmed that the strainer is clean and in good condition. 7 Yes i-No 17 N/A <br /> (enter m,3nufacturer and model number in Comments if I <br /> availabl€) <br /> Cb. Confirmed strainer basket, cap, bolts and gasket seal are 7 Yes J-No W, N/A <br /> in good condition. <br /> 5.7 F te.r a. Confirmed that the filter is in good condition and is within 7 Yes r No jv N/A <br /> the manufacturer's expected service life. Replace, if <br /> necessary.Make:,Model: <br /> b. Confirmed no leaks or decreased fuel flow. r Yes r No fJ N/A <br /> 5.8 +=ia,r;e armstors Inspected for proper operation per manufacturer's instructions 7 Yes r-No W N/A <br /> and no corrosion or blockage of air passages.(enter <br /> 1 manufacturer and model number in Comments if available) <br /> 5.9 Leak deteetor for Have been or were tested per manufacturer's instructions and [-Yes F No iv N/A <br /> {submersible pump systems authority having jurisdiction (AHJ)and verify leak detectors are <br /> suited and property installed for above ground use. <br /> Make: Model: I <br /> ( 5.10 Liquid Rovet equipment a. Make: Krueger,Model:T,ype H <br /> b. Has equipment been tested to ensure proper operation? j 1�Yes 7 No r NIA <br /> c. Does equipment operate as required? r Yes J No t"NIA <br /> d. Does the equipment perform per manufacturer's W,Yes T-No i"N/A <br /> instructions? <br /> M-, 6703206 SEP i EMBER 2016 <br />