Laserfiche WebLink
AST$P001 ANNUAL_INSPECTION <br /> _ itamn Task Status <br /> -G,Cathodlr. Protection <br /> 3.1 avanic;zthadicConfirm system is functional, includes the wire connections for s Yes r No W N/A <br /> Protection system galvanic systems, <br /> 3.2 Irnpressec;c,,rrent a. Inspect the components operational com <br /> p p (power switch, meters. and r-Yes r-No P N/A <br /> system alarms). <br /> i <br /> b. Record 'hour meter, ammeter and voltmeter readings. f Yes I-No P7 N/A <br /> c. Rectifier Jnit: Make:,Model: <br /> Comments: <br /> 4.0 sank Shell, Xeads, Roof <br /> 4.1 Goaungis the coating in good condition? ; Yes I No N/A <br /> 4.2 Steel condition Is structure ,ree of: <br /> le Dents W Yes r No r-N/A <br /> Bucklinc WO Yes r-No r-N/A <br /> f® Bulginc P-0 Yes 1-No !-NIA <br /> o Corrosion i:,Yes No l-N/A <br /> Crackinc l ry Yes T No r N/A <br /> 4.3 Root slope System is free of low points and standing water. Yes 1-No i7 N/A <br /> Comments.- <br /> 15.3 ?-ink Equipment _ <br /> 5 + Vents-Primary I Components are moving freely and vent passageways are not <br /> y obstructed for: Yes No W N/A <br /> �® r-mergency vent covers: Make: ,Model:, Diameter: r-Yes r No tv-N/A <br /> G e Normal Vent: Make: ,Model:, Diameter: <br /> 4 is Other moving vent components (enter manufacturer and model Yes No ¢v W.A. <br /> number, ir, Comments if available. <br /> 5.2 Ver is-Secondary Components are moving freely and vent passageways are not <br /> obstructed for I-Yes r No iv N/P, <br /> m Emergency vent covers:Make:,Model:,Diameter: rYes TNo r'v N/A <br /> ® Secondary Vent:Make:,Model:,Diameter: i I-Yes !-No N/A <br /> Other moving vent components(enter manufacturer and mode! <br /> number in Comments if available. <br /> j ornmen.ts: <br /> i <br /> 3Valves All valves are free of leaks, corrosion and damage. i"Yes `No <br /> 5.3.1 An-,i-s phc n, check I Cycle the valve open and closed and confirmed proper operation. I r Yes r-No 1 1 N/A <br /> Land vete+calves (enter manufacturer and model number in Comments if available) <br /> j 5.3.2€'ressure regulator Confirmed proper operation. (Note that there may be small, 1/4 inch F Yes r No i-N/A <br /> I vatv�s drain plugs in the bottom of the valve that are not visible by looking 1 <br /> from above only)(enter manufacturer and model number in <br /> Comments if available) <br /> 3.3 Expansion relief valve Confirmed that the valve is in the proper orientation. (Note that fuelI i Yes [—No fd NIA <br /> must be discharged back to the tank via a separate pipe or tubing.) <br /> (enter manufacturer and model number in Comments if available) <br /> 67032 SEP EMBER 2016 <br />