My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
500
>
2200 - Hazardous Waste Program
>
PR0514476
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2020 1:16:49 PM
Creation date
9/29/2020 3:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514476
PE
2229
FACILITY_ID
FA0010973
FACILITY_NAME
JIFFY LUBE #2322
STREET_NUMBER
500
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06208002
CURRENT_STATUS
01
SITE_LOCATION
500 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
514
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` RECHVE) <br /> JAN 2 6 1015 <br /> ENVIRONMENTAL <br /> Used oil is removed from the tank through two (2) inch steel piping which terminates at the sou%a'TP(TfA:h1T <br /> the building at the service level. There is currently a two (2) inch normal vent adjacent to the outlet suction pipe. <br /> The tank does not currently have the required emergency relief venting, not less than 147,000 cubic feet per hour <br /> (CFH) for the primary tank and not less than 168,000 CFH for the secondary tank, per the label on the front end <br /> of the tank. <br /> 3.2.1.4 Description of Any Internal and External Ptlnips <br /> An external pneumatic Graco Husky 1040 pump is used at the service pit drain pans(sumps)to direct used oil <br /> through the piping system towards the storage tank. <br /> 3.2.1.5 Tank Drawings) <br /> Please refer to Attachment 1 for typical tank configuration and Attachment 3 for configuration at time of <br /> inspection. <br /> 3.3 Age of Tank System [CCR§66265.192(k)(3)] <br /> The date of manufacture and/or installation of the tank is unavailable at this time, however,existing records <br /> indicate that the tank has been in operation at the site for at least 15 years. <br /> 3.4 Leak Detection [CCR§66265.192(k)(4)] <br /> Leak detection is part of the facility's daily inspection routine. On the tank, the annular space is visually <br /> inspected by opening the secondary tank emergency vent and looking to determine if used oil is present.Pipes and <br /> pumps are visually inspected for leaks. If a leak is observed,appropriate personnel are to be immediately notified <br /> and will provide direction on the best course of action. The tank will be immediately placed out of service and the <br /> containment cleaned out within 24 hours. The tank will remain out of service until such time that repairs can be <br /> made and a licensed professional engineer certifies the tank is suitable for service. <br /> 3.5 Corrosion Protection [CCR§66265.192(k)(5) & 192(a)(3)] <br /> A36 carbon steel and ASTM A-659 are compatible with waste oil. <br /> The exterior steel surfaces of the primary and secondary tank walls were coated with one coat of paint at the <br /> factory. At least one additional coat of paint was applied while the tank was installed at the Jiffy Lube facility. <br /> During the tank inspection, it was noted that the painted areas around the tank connections were showing signs of <br /> deterioration and in some cases base metal was visible. Based on the condition of the tank coating, a suitable <br /> coating must be reapplied. <br /> Based on information available at the time of inspection and report preparation, there is no corrosion protection <br /> measures internal to the tank. <br /> Ha=ardour Waste Tank System Assessment and Certification Page 6 of 9 NES,Inc. <br /> Broadbase,Inc. NESJob#276.EC1957.00 <br /> Lodi,California <br />
The URL can be used to link to this page
Your browser does not support the video tag.