My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2020 4:29:03 PM
Creation date
10/8/2020 7:37:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. UNDER-DISPENSER CONTAINMENT UDC TESTING <br /> Company Name: B.Z. Service Station Maintenance <br /> Company Address: 1041 Triangle Ct.,West Sacramento,CA 95605 <br /> Credentials: ® CSLB Licensed Contractor ❑ SWRCB Licensed Tank Tester <br /> License Type: ICC License Number: 433159 <br /> Test Equipment Used: INCON TS-STS Equipment Resolution: 0.0001 <br /> UDC# 1 UDC#2 UDC# lA UDC# <br /> UDC Manufacturer: UNK UNK UNK <br /> UDC Material: FBG FBG FBG <br /> UDC Depth: 9" V 9" <br /> Height from UDC Bottom to Top BOTTOM BOTTOM BOTTOM <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to BOTTOM BOTTOM BOTTOM <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to FAIR FAIR FAIR <br /> testing: <br /> Portion of UDC Tested' 9" V 9" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No❑NA <br /> product and water)?' <br /> Turbine shutdown response time N/A N/A N/A <br /> Is system programmed for fail- ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No❑NA <br /> safe shutdown?' <br /> Was fail-safe verified to be <br /> o erational?` El Yes[INo®NA El Yes[_1No®NA [:1 Yes❑No®NA [_1 Yes❑No❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and 15 MIN 15 MIN 15 MIN <br /> starting test <br /> Test Start Time: 1:58 1:58 2:20 <br /> Initial Reading(Ri): 2.5831 2.6029 1.4328 <br /> Test End Time: 2:13 2:13 2:35 <br /> Final Reading(RF): 2.5822 2.6023 1.4329 <br /> Test Duration: 15 MIN 15 MIN 15 MIN 15 MIN <br /> Change in Reading(RF-Ri): 0.0009 0.0006 0.0001 <br /> Pass/Fail Threshold or Criteria: 0.002 0.002 0.002 0.002 <br /> Test Result: ®Pass ❑Fail ®Pass ❑Fail ®Pass ❑ Fail ❑Pass ❑ Fail <br /> Was sensor removed for testing? ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No❑NA <br /> Was sensor properly replaced and ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No®NA ❑Yes❑No❑NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Secondary Containment Test Results 4 of 4 <br />