Laserfiche WebLink
UL/ ULC ® Piping <br /> SPECIFICATION <br /> Primary Piping <br /> SECTION 1 - Scope <br /> This section covers the use of fiberglass reinforced plastic 2 . 06 Acceptable Manufacturers - NOV Fiber Glass <br /> (FRP) pipe for single wall fuel handling and fuel handling vent Systems , 501 -568-4010 , or approved equal . <br /> and vapor applications Including gasoline , unleaded gasoline , <br /> gasoline/alcohol mixtures , blo -diesel , DEF and diesel up to Section 3 - Material and Construction <br /> 150°F and 250 psig cyclic pressure , <br /> 3 . 01 2 " - 4 " Pipe - The pipe shall be manufactured by <br /> the filament winding process using an amine cured epoxy <br /> SECTION 2 - General Conditions thermosetting resin to Impregnate strands of continuous <br /> 2 .01 Coordination - Material furnished and work glass filaments , which are wound around a mandrel at a <br /> performed under this section shall be coordinated with the 543/4" winding angle under controlled tension . The pipe <br /> related work and equipment specified under other sections, shall be heat cured and the cure shall be confirmed using a <br /> Le . Valves, Flexible Connectors , Equipment , Differential Scanning Calorimeter, <br /> Pipe shall be supplied with a T. A . B . "' (Threaded and <br /> 2 . 02 Governing Standards - Except as modified or Bonded) ends . <br /> supplemented herein , all materials and construction methods Pipe shall have a minimum continuous cyclic pressure <br /> shall comply with and be tested in accordance with the rating of 125 psig at 150°F In accordance with ASTM D2992 , <br /> following standards and test methods : Procedure A or UL 971 pressure rating . <br /> Standards and Test Methods : All pipe shall be 100% hydrotested at the factory before <br /> shipment at a minimum pressure of 265 psig and shall be <br /> UL971 Standard for Nonmetallic Underground Piping for Flam - UL971 -2004 Listed and labeled . <br /> 2004 mable Liquids <br /> 3 . 02 ASTM D2310 Classifications (at 73 . 40F) <br /> ASTM Standard Classification for MachineWade " Fiberglass" 2" - all RTRP- 1 1 AF <br /> D2310 ( Glass Fiber Reinforced Thermosetting Resin ) Pipe <br /> ASTM Standard practice for obtaining Hydrostatic or Pressure 4" RTRP- 11 AH <br /> D2992 Design Basis for " Fiberglass" (Glass Fiber Reinforced ( Mechanical properties cell classifications shown are <br /> Thermosetting Resin ) Pipe and Fittings minimums .) <br /> 3 . 03 Fittings - All fittings shall be manufactured using <br /> 2 . 03 Operating Conditions - In addition to the above the same type of material as the pipe , Fittings may be <br /> listed minimum design requirements, the system shall meet manufactured either by compression molding , filament <br /> the following minimum operating conditions : winding , resin transfer molding or contact molding methods . <br /> All fittings , adapter, and sump penetrations shall be UL971 - <br /> a. Operating Pressure 2004 Listed . <br /> b . Fluid Conveyed Fittings shall be adhesive bonded matched tapered bell <br /> c . Test Pressure and spigot . <br /> 3 . 04 Connections - Connections to flex connectors or <br /> 2 . 04 Quality Assurance - Pipe manufacturer' s quality other piping materials shall be made by the use of NPT <br /> program shall be In compliance with ISO 9001 and/or API Q1 . (National Pipe Thread) threaded adapters or flanges bonded <br /> to the FRP piping system , <br /> 2 .05 Delivery. Storage . and Handling - Pipe and fittings 3 . 05 Sump Penetrations - Sump penetrations shall be <br /> shall be protected from damage due to Impact and point made by means of a permanently bonded FRP coupling . The <br /> loading . Pipe shall be properly supported to avoid damage coupling shall be capable of adjusting for the slope of the <br /> due to flexural strain . The contractor shall not allow dirt , piping system entering or exiting the sump wall , <br /> debris or other extraneous materials to get Into pipe and 3 .06 Adhesives - Adhesives shall be manufacturer' s <br /> fittings . All factory machined areas shall be protected from standard for the piping system specified . <br /> sunlight until Installed , <br /> v~w. f9splipe . com fgspipe@ncv. c® rn KW Fiber Glass Systems <br />