My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2022 4:53:31 PM
Creation date
10/26/2020 1:04:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health DepartmentUnderground Storage Tank Program Inspection ReportDate:December 16, 2020Facility Address:8660 LOWER SACRAMENTO RD, STOCKTONFacility Name:fast and easy mart #103SUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR - Notice to Comply)RemarksItem #206CCR 2712(i), 2634(e) Failure to have a current UST Response Plan available on site. OBSERVATION: An approved copy of the response plan was not available on site for inspection. REGULATION GUIDANCE: A copy of this plan shall be accessible on site at all times. CORRECTIVE ACTION: Immediately locate and retain a copy on site.This is a minor violation.208CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. 1) OBSERVATION: The designated operator inspections for the following months were performed more than 30 days after the previous inspection:- Initial inspection on 7/18/2019, next inspection performed on 8/19/2019 (31 days)- Initial inspection on 10/17/2019, next inspection performed on 11/19/2019 (32 days)- Initial inspection on 12/17/2019, next inspection performed on 01/23/2020 (36 days)- Initial inspection on 04/10/2020, next inspection performed on 05/13/2020 (32 days)- Initial inspection on 06/11/2020, next inspection performed on 07/13/2020 (31 days)- Initial inspection on 08/13/2020, next inspection performed on 09/20/2020 (36 days)REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of the previous inspection. CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time frames.2) OBSERVATION: The designated operator failed to check and note all required items on the visual inspection reports. The incorrect and missing information included the following from the inspection reports:- Section V and VI of the DO's report were left blank.REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required testing and maintenance for the UST system have been completed and shall check all required items on the report. CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including all of the required information on the reports.This is a minor violation.FA0003726 PR0231161 SC001 12/16/2020EHD 23-01 Rev. 9/16/2020Underground Storage Tank Program OIRPage 7 of 91868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.